• Title/Summary/Keyword: Glass Cap

Search Result 50, Processing Time 0.027 seconds

Development of detachable air-cap module for improving the performance of windows (창호 성능 개선을 위한 에어캡 탈부착형 모듈 개발)

  • Seo, Beomdong;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Purpose: Various studies to solve the problem of increased energy consumption in the buildings are being carried out recently. Especially, the economic feasibility and insulation performance of the air-cap have been verified so that various studies regarding the reduction of building energy consumption have been carried out. However, previous studies regarding the air-cap were only carried out based on the verification of its insulation performance according to the size and attachment position of the air-cap. Therefore, the purpose of this study is to suggest a detachable air-cap module for improving the performance of the windows, evaluate the performance based on cooling, heating and light environments and verify its effectiveness through a real-scale testbed. Method: In this study, the energy saving performance in the circumstance where there is no attachment of an air-cap (Case 1), the circumstance where there is the attachment of air-cap on the glass surface of window (Case 2) and the circumstance where there is the attachment of an air-cap on the window frame (Case 3) were compared in order to verify the performance of the detachable air-cap module (Case 4), and the electricity consumption of cooling, heating and lighting equipment to maintain the appropriate indoor temperature and Illuminance for each case was calculated and utilized as indicators for the performance evaluation. Result: The result of this study is as follows. 1) In this study, the detachable air-cap module which was easily detachable through the principle of the magnet was suggested. 2) When Case 4 is applied, the electricity consumption of cooling and heating equipment can be reduced by 27.5%, 13.2% and 3.4% in comparison with Case 1, Case 2 and Case 3 respectively. 3) When the air-cap is applied to the window, the lighting energy consumption increases by 4 % in comparison to the non application of the air-cap, and this factor or aspect should be considered when applying the air-cap. 4) According to the performance evaluation result in consideration of cooling, heating and light environments, Case 4 demonstrates an energy saving ratio of 22.6%, 10.6% and 2.7% in comparison to Case 1, Case 2 and Case 3 respectively, indicating that it is effective for improving the performance of windows.

Experimental study of the heat pipe phenomenon in porous media heated from above (상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구)

  • 이진호;김홍제;함윤영;남궁규완
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.825-832
    • /
    • 1988
  • An experiment was performed to study the heat pipe phenomenon of porous media heated above at one-dimensional steady state for the range of heat flux, 300 W/ $m^{2}$ ~ 2000w/ $m^{2}$. Glass beads, sand, and copper particles were used as porous media and distilled water was used as a working fluid. Result of experiment shows that the length of the two-phase zone increases with the decreasing particle size for the same heat flux. At relatively lower heat flux the length of the two-phase zone increases with the increasing heat flux, which contradicts the result of earlier work. However, its length remains nearly constant when the heat flux increases above a certain value. The length of the two-phase zone is proportional to the product of the heat flux by the hydrostatic capillary height under the limited value on heat flux, that is, $l_{t}$ = A(q. $l_{cap}$)+B, q.leg.1/A(C+B/ $l_{cap}$) where A is 1.7*10$^{-4}$ $m^{2}$/w, B is 1.9*10$^{-2}$ m, and C is 0.43 for copper particles and 0.31 for glass beads and sand.d.d.d.

Respiratory Virus Detection Rate in Patients with Severe or Atypical Community-acquired Pneumonia (중증 또는 비전형적 지역사회획득 폐렴으로 입원한 환자에서 호흡기 바이러스의 검출 빈도)

  • Park, Ji-Won;Jung, Sun-Young;Eun, Hyuk-Soo;Cheon, Shin-Hye;Seong, Seok-Woo;Park, Dong-Il;Park, Myung-Rin;Park, Hee-Sun;Jung, Sung-Soo;Kim, Ju-Ock;Kim, Sun-Young;Lee, Jeong-Eun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.5
    • /
    • pp.335-340
    • /
    • 2011
  • Background: Community-acquired pneumonia (CAP) is an important cause of morbidity and mortality throughout the world in all age groups. Viral causes of CAP are less well characterized than bacterial causes. We analyzed the characteristics of hospitalized patients with CAP who had a viral pathogen detected by multiplex polymerase chain reaction (PCR). Methods: Multiplex real-time PCR was performed for respiratory viruses in samples collected from 520 adults who developed CAP at Chungnam National University Hospital. Clinical, laboratory, and radiological features at presentation as well as other epidemiological data were analyzed. Results: Of 520 patients with CAP, a viral pathogen was detected in 60 (11.5%), and influenza A was the most common. The virus detection rate in patients with CAP was highest in November. Two or more pathogens were detected in 13 (21.7%) patients. Seven patients had severe disease and were administered in the intensive care unit. Most patients (49/60, 81.7%) had comorbidities. However, nine (15%) patients had no comorbidities, and their age was <60 years. The ground glass opacity pattern was the most common radiological feature. Seven (11.7%) patients died from CAP. Conclusion: Viral pathogens are commonly detected in patients with CAP, and a respiratory virus may be associated with the severity and outcome of pneumonia. Careful attention should be paid to the viral etiology in adult patients with CAP.

Wafer-Level Package of RF MEMS Switch using Au/Sn Eutectic Bonding and Glass Dry Etch (금/주석 공융점 접합과 유리 기판의 건식 식각을 이용한 고주파 MEMS 스위치의 기판 단위 실장)

  • Kang, Sung-Chan;Jang, Yeon-Su;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • A low loss radio frequency(RF) micro electro mechanical systems(MEMS) switch driven by a low actuation voltage was designed for the development of a new RF MEMS switch. The RF MEMS switch should be encapsulated. The glass cap and fabricated RF MEMS switch were assembled by the Au/Sn eutectic bonding principle for wafer-level packaging. The through-vias on the glass substrate was made by the glass dry etching and Au electroplating process. The packaged RF MEMS switch had an actuation voltage of 12.5 V, an insertion loss below 0.25 dB, a return loss above 16.6 dB, and an isolation value above 41.4 dB at 6 GHz.

Magnetoresistance of Co/Cu/Co Spin Valve Sandwiches

  • Park, S. J.;Park, K. L.;Kim, M. Y.;j. R. Rhee;D. G. Hwang;Lee, S. S.;Lee, k. A.;Park, C. M.
    • Journal of Magnetics
    • /
    • v.2 no.1
    • /
    • pp.7-11
    • /
    • 1997
  • The dependence of magnetoresistance (MR) ratio on various variables like the thickness of the second Co layer, on the presence of cap layer, on deposition field (Hdep) and on annealing in Co/Cu/Co sandwiches was investigated. Spin-valve sandwiches were deposited on the corning glass by means of the 3-gun dcmagnetron sputtering at a 5 mTorr partial Ar pressure and room temperature. The deposition field was varied from 70 Oe to 720 Oe. The MR curve was measured by the four-terminal method with applied magnetic field up to 1000 Oe perpendicular to the direction of a current in the film plne. The MR ratio of glass/Fe(50${\AA}$)/Co(17${\AA}$)/Cu(24${\AA}$)/Cot(${\AA}$) fabricated by making 50 ${\AA}$ of Fe buffer layer has the maximum value of 8.2% when the thickness of the second Co layer was 17${\AA}$and the deposition field was 350 Oe. In the case of glass/Fe(50${\AA}$)/Co(17${\AA}$)/Cu(24${\AA}$)/Cot(${\AA}$) with Cu cap layer on top, the decrease in the MR ratio seemed to relate with the oxidation of the second Co layer. Samples prepared with deposition field showed greater MR ratios through the formation of more complete spin valve films. After annealing for 2 hours at 300$^{\circ}C$, the MR ratio of the samples prepared with deposition field decreased rapidly while the MR raito of the sample prepared without the field remained.

  • PDF

Study on the solution for the overflow of molten solder during the soldering of fuse cap through CFD analysis (전산유체해석을 통한 퓨즈캡 솔더링 시의 용융솔더 넘침 문제 해결방안 연구)

  • Jeong, Nam-Gyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.31-36
    • /
    • 2018
  • Fuses are used to protect electric circuits or devices from excess current. Glass-tube fuses are typically used, but problems have arisen due to the mandated switch from conventional solder to lead-free solder. This study used CFD to simulate the phenomenon of molten solder being poured out of a fuse during the soldering process for a fuse cap and fuse element. In addition, a method is proposed to prevent solder from overflowing, and its effectiveness was verified based on the analysis results. The results show that a sufficient increase of the temperature inside the glass tube before soldering and gravity can help to prevent the solder from overflowing.

Compressive Strength of Unidirectional Glass/Epoxy Specimens Processed by Wet Lay-up at Room Temperature (수작업/상온경화시킨 일방향 Glass/Epoxy 시편의 압축강도)

  • Lee, Jong-Won;Kim, Jin-Won
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • The present study provides the compressive design allowable of a unidirectional glass/epoxy composite laminate processed by wet lay-up at room temperature. The compressive strength values measured from 39 specimens have been assumed to follow the two-parameter Weibull distribution. Following the statistical guidelines provided by MIL-HDBK-17F, the B-basis and A-basis values of the aforementioned laminate are found to be 82.6% and 65.9%, of the mean compressive strength, respectively. The B-basis value is then discounted further at 50% for the in-situ application on the main wing spar caps of an experimental canard aircraft.

  • PDF

Porosity Control of the Sealing Glass for Joining Alumina Components in a NaS Battery Cell Packaging (NaS 배터리 셀 패키지의 알루미나 컴포넌트 접합용 Sealing Glass의 기공율 제어)

  • Kim, Chi Heon;Heo, Yu Jin;Kim, Hyo Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.57-61
    • /
    • 2016
  • Thick film sealing glass paste is required for cell packaging of NaS based battery for energy storage system, to join the beta-alumina electrolyte tube and the alpha-alumina battery cell cap components. This paper presents the effect of the particle sizes of seal glass powder and the sealing temperatures on the microstructure of the glass sealants was investigated. It was found that the larger in the particle size of seal glass powder, the smaller the pore volume and the number of pores in a unit area. Also, the number of pores decreased with increasing the sealing temperatures while the pore size was increased. This result enables the control of porosity, pore distribution and number of pores in a microstructure of glass sealing component by proper selection of glass powders particle size and sealing temperature.

Fabrication and Adhesion Strength Evaluation of Glass Sealants for Ceramic to Ceramic Component Joining (세라믹-세라믹 컴포넌트 접합용 글라스 실란트의 제조 및 접합력 평가)

  • Heo, Yu Jin;Kim, Hyo Tae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.89-94
    • /
    • 2019
  • Glass base sealant is required as a ceramic-ceramic joining material between α-alumina insulation cap and β-alumina electrolyte tube in the development of NaS battery cell package for electrical energy storage system. The fabrication of glass frit by thermal quenching method, phase analysis, particle size analysis, coefficient of thermal expansion and surface roughness according to the glass compositions were analyzed for the fabrication of glass sealing paste for ceramic-ceramic joining. Also, a new evaluation method of the adhesion strength of glass sealant at the small area in ceramic-ceramic joining component was proposed using conventional Dage bond tester that was used to measure the adhesion of solder ball joint.

Thickness Optimization for Spar Cap of Composite Tidal Current Turbine Blade using SQP Method (SQP법을 사용한 복합재 조류력 발전용 블레이드의 스파 캡에 대한 두께 최적화)

  • Cha, Myung-Chan;Kim, Sang-Woo;Jeong, Min-Soo;Lee, In;Yoo, Seung-Jae;Park, Cheon-Jin
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.207-212
    • /
    • 2013
  • In this study, the thickness optimization for uni-directional (UD) glass fiber reinforced polymer (GFRP) laminates of the spar cap of composite tidal blades was performed under the tip deflection constrains. The spar cap was composed of GFRP composites and carbon fiber reinforced polymer (CFRP) composites. The stress distributions in the blade as well as its material costs for the optimized results were additionally investigated. The optimized thickness was obtained by interacting a sequential quadratic programming (SQP) algorithm and an ABAQUS software to calculate an objective function. It was confirmed that the thickness of UD GFRP increased with a decrease of the restrained tip deflection when a thickness of UD CFRP laminates was constrained to 9 mm. The weight of the optimized spar-cap increased up to 96.2% while the maximum longitudinal tensile stress decreased up to 24.6%. The thickness of UD GFRP laminates increased with a decrease of the thickness of UD CFRP laminates when the tip deflection was constrained to 126.83 mm. The weight increased up to 40.1%, but the material cost decreased up to 16.97%. Finally, the relationships among the weight, internal tensile stress, and material costs were presented based on the optimized thicknesses of the spar cap.