• 제목/요약/키워드: Glandular dose

검색결과 46건 처리시간 0.025초

보형물 삽입 유방의 압박 두께에 따른 유방 선량 평가 (Evaluation of Breast Dose by Breast Pressure Thickness of Breast Prosthesis Insertion)

  • 이현용;김지수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권6호
    • /
    • pp.469-473
    • /
    • 2020
  • Breast cancer is growing rapidly year by year and has the highest incidence since 2001. As a result, the interest in mammography for early detection of breast cancer is increasing. However, mammography is accompanied by radiation exposure and therefore it is necessary to reduce exposure dose through appropriate test conditions. The significance of this study is that breast dose studies, which were limited to ordinary women, were applied to breast implant patient. Using MCNP simulation, the phantom with prosthesis inserted was developed to compare dose by tube voltage by pressure thickness. In addition phantom without prostheses has higher dose than phantom with prostheses. If these results were used as basic data, it would be possible to recommend test condition guideline only for breast implant patients.

유방촬영검사에서 선량지표분석에 대한 모니터링 (Monitoring on Dose Index Analyzed in the Mammography)

  • 조지환;이효영;임인철
    • 한국방사선학회논문지
    • /
    • 제10권7호
    • /
    • pp.477-482
    • /
    • 2016
  • 유방촬영검사(Mammography)에서 선량지표를 분석하여 한국식품의약품안전처(Korea Food & Drug Administ ration)에서 제시하는 가이드라인과 비교분석하여 의료방사선의 관리가 잘 이루어지고 있는지 파악하고자 하였다. 방법으로는 유방촬영검사를 시행한 후 의료영상저장정보시스템(Picture Archiving Communication System, PACS)으로 전송되어진 선량 보고서(dose report)와 의료전자차트(Electronic Medical Record, EMR)를 참고하여 양쪽 유방 상하방향촬영(cranio-caudal, CC), 내외 사방향 촬영(medio-lateral oblique, MLO)검사에서 관전압(kVp), 조사시간(exposure time), 관전류량(mAs), 유방압박두께(compressed breast thickness), 평균유선선량(average glandular dose), 체질량지수(Body Mass Index, BMI)를 분류하여 분석하였다. 결과적으로 연령별에 따른 검사부위 CC, MLO에서 유방압박두께는 50-59세에서 45.6 mm, 49.6 mm로 가장 두껍게 나타났으며 전체적인 평균유방압박두께는 CC에서 44.2 mm, MLO 48.9 mm로 MLO가 4.7 mm 더 두껍게 나타났다. 평균유선선량은 CC에서 1.05 mGy, MLO에서 1.14 mGy로 CC보다 MLO에서 0.09 mGy가 더 높게 나타났으며 유방압박두께가 10 mm 증가할수록 CC와 MLO에서는 0.15 mGy, 0.17 mGy가 증가하는 것으로 나타났다. 한국식품의약품안전처에서 제시하는 유방 CC에서 1매 촬영 시 환자가 받는 평균유선선량 1.16 mGy 평가와 비교했을 시 1.05 mGy로 나타났으나 60 mm이상에서는 1.30 mGy로 초과하는 것으로 나타났다. 또한 유방압박두께가 높을수록 체질량지수가 높게 나타났으며 체질량지수에 따른 비만기준 25이상인 경우는 유방압박두께가 50 mm 이상일 경우에 비만인 것으로 나타났다.

가임기 여성의 유방촬영에서 Dose mode 적용의 유용성 분석 (The Usefulness Analysis of Applying Dose Mode in Mammography Women of Childbearing Age)

  • 이소라;손순룡;정재연;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.19-23
    • /
    • 2013
  • Purpose : Automatic exposure system(AOP mode) in DR Mammography of the STD and DOSE apply to women of childbearing age, the average glandular dose(AGD) and image quality by comparing was to demonstrate the usefulness of DOSE. Materials and Methods : Of the under 40 age 108 patients who visit to our hospital and examined STD and DOSE mammography from January 2008 to July 2013. AGD was obtained by DICOM header information provided by GE Senographe DS. STD and DOSE images were evaluated with obtained patients, Image J program was compared by calculating the SNR. Results : The average AGD of DOSE mode was 0.99mGy, and which decreased by 19% comparing to that of STD mode which was 1.18mGy. The two the average AGDs indicated statistically significant difference(p< .01). The average SNR of STD was 40.26, DOSE displayed, and to 39.68 in, there was no statistical significance. Results : The average AGD using DOSE mode which is one of DR mammography AOP modes decreased by comparing to that of STD mode showing no difference in image quality. The use of DOSE is considered to be useful.

  • PDF

MLO View의 유방촬영에서 QC 프로그램을 이용한 선량 및 영상 평가 (Evaluation of Radiation Dose and Imaging of the QC Program in Mammography MLO View)

  • 이선화;김정민;권대철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.221-228
    • /
    • 2015
  • 목적: 디지털 유방촬영에서 QC 프로그램을 이용하여 방사선 피폭 선량의 감소와 고화질의 영상을 목적으로 하였다. 재료 및 방법: 디지털 유방촬영술에서 QC phantom을 사용하여 노출 방식에 따른 평균유선선량을 MLO view에서 $0^{\circ}C$, $30^{\circ}C$, $45^{\circ}C$, $50^{\circ}C$, $55^{\circ}C$, $70^{\circ}C$, $90^{\circ}C$ 구간에서 측정하였고, Hologic사의 QC 프로그램으로 영상에서 SNR과 CNR을 측정하여 평가하였다. 결과: 평균유선선량은 $90^{\circ}C$ 일 때 1.75 mGy로 최대치였고, $45^{\circ}C$에서 약 6 % 감소한 1.65 mGy 측정되었다. 또한 auto filter에서 1.67 mGy, manual에서는 1.52 mGy의 평균유선선량을 기록하여 노출 방식에 따라 선량이 차이가 있었다. 화질평가의 모든 각도 구간에서 SNR 50~52, CNR 11~12로 근소한 차이를 나타내고, 제조사의 권고치 내에 포함되었다. 결론: MLO view $45^{\circ}C$에서 가장 적은 선량이었고, SNR 및 CNR의 차이는 미미하였다. 이때의 노출방식은 환자의 체형이나 특성을 고려한 설정으로 차이를 두어 불필요한 환자의 피폭 선량을 줄이기 위한 방법이 필요하다.

유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가 (Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography)

  • 김지수;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.

Mammography시 Thyroid에 미치는 산란선량에 관한 연구 (The Effect of Scattering Dose on the Thyroid During Mammography)

  • 이미화;동경래;박서주;황선광
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.826-830
    • /
    • 2010
  • This study examined the effect of the scattering dose on the thyroid during a mammography examination. One hundred subjects for a mammography examination were enrolled in this study. The average glandular dose (AGD) and thyroid scattering dose (TSD) were measured. Statistical analysis was carried out using the percentage, t-test and co-variance. The mean radiation exposure to the breast and thyroid was $1.08{\pm}0.16$ and $0.14{\pm}0.04$ mGy, respectively. The percentage TSD to the AGD was 31.19%. There was no difference between the Rt. and Lt., and CC to MLO, and radiation dose to the TSD was 13.78% of the breast. Therefore, the volume of radiation exposure to the thyroid was 54.12% in a single routine mammography examination. These results suggest that the TSD was increased by increasing radiation dose to the breast. A thyroid protector is considered necessary to decrease the level of radiation exposure.

Dexamethasone을 투여(投與)한 Rat 유선조직(乳腺組織)의 병리조직학적(病理組織學的) 관찰(觀察) (A Histopathological Observation on the Mammary Gland of Lactating Rat Injected with Dexamethasone)

  • 류시윤;이차수
    • 대한수의학회지
    • /
    • 제23권1호
    • /
    • pp.57-67
    • /
    • 1983
  • The present study was carried out to observe the histopathological changes in the mammary gland of lactating rats and rabbits injected with dexamethasone. White rats were intramuscularly injected with 0.25mg, 0.5mg or 1.0mg of dexamethasone sodium phosphate (containing $9{\alpha}$-fluoro-$16{\alpha}$-methylprednisolone, 5.0mg/ml) daily for 3 to 10 days on the 3rd day after parturition and white rabbits were intramammary infused with 4mg or 20mg of dexamethasone daily for 4 days on 7th day after parturition. The histopathological changes of the mammary glands, ovaries and adrenal glands of rats and rabbits were observed with light microscope. In the mammary glands of rats, the microscopic findings encountered were decrease of the milk in the alveolar lumina, necrosis and desquamation of epithelial cells, atrophy of alveoli, proliferation of fibroblasts and thickness of alveolar walls, destruction of alveoli, presence of fat droplets within the glandular epithelial cells, infiltration of mononuclear cells and proliferation of adipose tissue, which were relative to the dose and duration of injection. Especially, in the cases of the administration of large doses or long duration, there were severe fibrosis and focal necrosis of glandular tissue. In the mammary glands of rabbits, the morphological changes were similar to those findings in the rats. The milk in the alveolar lumina was decreased gradually according to the dose and duration of injection, while milk fat concentration regarded to increase. In the histological findings of ovaries, necrosis of granulosa cellos, vacuolization and necrosis of luteal cells, atrophy and necrotic foci in the corpora lutes were observed. In the adrenal glands, hyperemia, hemorrhage, vacuolization of adrenal cortical cells, necrotic foci and atrophy of adrenal cortex were observed.

  • PDF

유방영상시스템에서 수학적 모의피폭체를 이용한 선량평가 (Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System)

  • 이진수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.155-161
    • /
    • 2014
  • 유방촬영의 경우 대부분 양쪽 유방에 대해 연속촬영이 시행되고 있으며, 검사 시 규정하고 있는 3 mGy의 평균유선선량 보다 낮다 하더라도 추가 검사 및 연속촬영으로 인해 실제는 더 많은 선량을 받게 된다. 또한 검사 유방 외에 주변장기선량에 대해 인지하기 어렵다. 이에 본 연구는 유방영상시스템에서 수학적 모의피폭체를 이용하여 필터의 두께 변화(25, 30, $50{\mu}m$)에 따른 주변장기 선량분포와 검사측 유방을 기준으로 한 상대적 흡수선량률을 알아보았다. 그 결과 검사 반대 유방의 선량이 검사 유방을 기준으로 79.26~86.31%정도로 많은 영향이 미치는 것으로 나타났으며, Mo/Mo, W/Rh 조합에서 실제 사용되고 있는 필터 두께 $30{\mu}m$, $50{\mu}m$ 보다 얇은 $25{\mu}m$를 사용했을 때 검사 반대 유방과 주변장기의 상대적 흡수선량률이 낮게 나타났다.

평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석 (Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD)

  • 박혜숙;김희중;이창래;조효민;유아람
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.21-29
    • /
    • 2009
  • 유방암은 우리나라 여성에게 발생하는 암 중에서 발병률이 높은 암이다. 따라서 유방자가진단, 임상적 검사, 유방 X선촬영 등과 같은 유방암 초기 검출검사는 중요하다. 이들 중 유방 X선촬영은 무자각증상 시기에 유방암 초기 검출을 위해 40대 이상의 여성들에게 매년마다 시행하기를 권고하고 있다. 그러나 유방의 유선조직은 방사선 민감성 조직이다. 이에 유방 X선촬영장치의 평가 중 평균 유선선량 측정은 매우 중요한 부분이 된다. 평균 유선선량의 직접측정은 어렵기 때문에 incident air kerma 측정, 적절한 변환계수 등을 적용하여 계산하게 된다. 따라서 본 연구의 첫 번째 목적은 평균 유선선량의 측정 방법의 표준화이다. 두 번째는 몬테칼로 시뮬레이션을 이용하여 평균 유선선량과 유방 실질양상 및 두께와 의 상관관계를 분석하고자 했다. 본 연구 결과, IAEA 가이드라인(CoP)에 따라 평균 유선선량 측정방법을 제시하였다. 전반적으로 우리나라는 유방촬영 시 받는 평균 유선선량이 식품의약품안전청 및 한국의료영상품질관리원에서 제시하는 3mGy 이하로 측정되었다. 측정된 평균 유선선량과 시뮬레이션된 평균 유선선량은 각각 1.7과 1.6 mGy로 큰 차이를 보이지 않았다. 시뮬레이션된 평균 유선선량은 주로 유방의 유선조직의 비율에 따라 의존한다. 유방의 glandularity 증가에 따라 낮은 에너지의 광자의 흡수가 증가하여 평균 유선선량도 증가하였다. 또한 유방의 두께가 두꺼울수록 평균 유선선량은 증가하였다. 결과적으로, 본 연구는 유방촬영의 진단 참고준위 확립을 위한 기초자료로 활용될 것이다.

  • PDF

유방 X선촬영 시 피폭선량에 대한 조사 연구 (A Survey on Radiation Exposure of Patient in Mammography)

  • 김형철;조평곤;김성수;최종학;김유현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권4호
    • /
    • pp.55-60
    • /
    • 2004
  • 유방 X선촬영검사에서 환자가 받는 피폭선량과 장치의 이용 현황을 조사하기 위하여, 대한병원협회에 등록된 전국의 278개 의료기관(종합병원)에 설문지를 발송하여 설문에 응답한 161개 의료기관의 자료를 분석하였다. 조사 결과, 평균유선선량은 0.5 mGy 이하 14.9%, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, 3.01 mGy 이상 7.4%이었다. 92.6%가 3 mGy 이하로 조사되었으며, 식품의약품안정청이 정한 평균유선선량 한도치인 3 mGy 근사값을 응답한 곳이 많았다. 최근, ICRP 등 방사선 방어 관련 국제기구는 유방 X선 촬영에서 평균유선선량을 성인 환자(50%지방, 50%유선)에 대해서 Mo target+Mo filter, 필름/스크린 시스템, 상하방향 촬영에서 4.2 cm로 압박된 유방에 대해서 1방향 3 mGy 이하로 제시하고 있으며, 점차 2 mGy, 또는 1.5 mGy로 낮추어 엄격하게 권고하고 있다. 따라서, 우리나라에서 유방 X선 촬영검사를 시행함에 있어 환자에 대한 피폭선량을 감소하기 위한 관심과 대책이 절실하게 요구된다. 아울러, 이번 조사를 바탕으로 의료기관의 유방 X선촬영 시 피폭선량을 실측하여 우리나라의 유방 X선촬영 시 환자피폭선량의 기준을 개발하기 위한 연구를 계속할 예정이다.

  • PDF