Abstract
Mammography is mostly performed by series projection on both breasts. While taking mammography, it is less than average glandular dose of 3 mGy which regulated. But mammography is exposed much more doses actually, due to additional or series projection. Also, it is difficult to recognize around organ dose except exposed breast. Using mathematical simulation of radiation exposure body in mammography, we studied around organ dose distribution by changing thickness(25, 30, $50{\mu}m$) of filter and relative absorption dose rate which set on basis of exposed breast. as a result, when setting of basis of exposed breast, dose of opposite breast is more affected approximately from 79.26 to 86.31%. when using $25{\mu}m$ of filter thickness than $30{\mu}m$, $50{\mu}m$ of filter thickness in Mo/Mo, W/Rh combination which used actually, absorbed dose rates for opposite breast and around organ were low.
Keywords
mammography; Mathematical simulation of radiation exposure body; organ dose;
Citations & Related Records
Times Cited By KSCI : 7  (Citation Analysis)
연도 인용수 순위
1 Kim JE, Im IC, Park CW, "An Assessment of Entrance Surface Dose Using the naonDot Dosimeter", J. Korean Soc. Radiology, Vol. 5, No. 6, pp.377-381, 2011.   DOI   ScienceOn
2 Kim JH, "Study on the S-value and Internal Residence Time of Radioiodine Upon the Thyroid of Standard Korean as a Source Organ", The graduate school of Kyung Hee University, 2007.
3 Oh KK, "Establishment of Reference Level of Radiation Dose in Mammography", The Annual Report of KFDA, Vol. 10, 2006.
4 Jang SY, Oh WG, Park JB, Jin GH, "The energy spectrum and phantom image quality according to mammography target-filter combinations", J. Korean Soc. Radiology, Vol. 7, No. 1, pp.51-55, 2013.   과학기술학회마을   DOI   ScienceOn
5 Cho WI, Kim YK, Lee GD, "Change of Dose Exposure and Improvement of Image Quality by Additional Filtration in Mammography", Journal of Radiation Protection, Vol. 38, No. 2, pp.78-90, 2013.   과학기술학회마을   DOI   ScienceOn
6 Yoon HJ, Kim MH, Choi YH, "Effective Computer-Aided Diagnosis Analysis for the Plaque Measurement on the Ultrasound image of the Carotid Artery", J Korean Soc. Ultrasound in Medicine, Vol. 23 No. 2, pp.105-111, 2004.   과학기술학회마을
7 Elmore JG, Amstrong K, Lhman CD, Fletcher SW, "Screening for breast cancer" JAMA, Vol. 293, No. 10, pp.1246-1256, 2005.
8 Kim MY, Kim HS, "The Evaluation of Radiation Dose by Exposure Method in Digital Magnification Mammography", The J. Korean Soc. Radiol. Science, Vol. 35, No. 4, pp.293-298, 2012.   과학기술학회마을
9 Choi SY, Ko SJ, Kang SS, "Denoising of Digital Mammography Images Using Wavelet Transform", J. Korean Soc. Radiology, Vol. 7, No. 3, pp.181-189, 2013.   과학기술학회마을   DOI   ScienceOn
10 Yang HJ, Ko SK, Joo MH, "Evaluation of MTF Image by Target/Filter Combination of X-ray Tube Using Mammography", J. Korean Soc. Radiol, Vol. 30, No. 2, pp.293-298, 2007.
11 Obenauer S, Hermann KP, Grabbe E, "Dose reduction in full-field digital mammography: an anthropomorphic breast phantom study", Br J Radiol, Vol.76, No. 907, pp.478-482, 2003.   DOI   ScienceOn
12 Cristy M, Eckeman KF, "SpecifGH Absorbed Fractions of Energy at Various Ages from Internal Phantom Sources", Oak Ridge National Laboratory Report ORNL/TM8381/VI, 1987.
13 Lee IJ, "Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter", J. Korean Soc. Radiol. Science, Vol. 32, No. 3, pp.261-270, 2009.   과학기술학회마을
14 Synder WS, Ford MR, Warner GG, "Estimates of Specific Absorbed Frraction for Photon Source Uniformity Distributed in Various Organ of a Heterogeneous Phantom", Society of Nuclear Medicine, New York, MIRD Pamphlet No.5 Revised, 1978.