• Title/Summary/Keyword: Girder stress

Search Result 366, Processing Time 0.024 seconds

Repair and Retrofit of Fatigue crack for Curved Girder Bridge (곡선 강교량 피로균열 보수.보강방안)

  • Park, Jin-Eun;Kyung, Kab-Soo;Kwon, Soon-Cheol;Lee, Hee-Hyun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.50-55
    • /
    • 2008
  • In order to investigate and estimate the cause of fatigue crack occurred to curved girder bridge that is used during 20 years, in this study, filed tests to obtain the characteristic of stress hysteresis were performed under the real traffic flows. From these test results, we analyzed the cause of fatigue crack for various fatigue crack patterns. Also, the characteristic of structural behavior for the curved girder bridge were examined from the FE analysis. In addition, to retrofit various fatigue cracks occurred in the bridge, FE analyses considering the characteristics of crack patterns were performed and retrofitting methods were suggested.

  • PDF

The Effect of Design Parameter on the Beam Depth of IPC Girder Continuous Bridge (교량설계 변수가 IPC 거더 연속교의 형고에 미치는 영향)

  • 한만엽;김보형;김상완
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.125-130
    • /
    • 2001
  • A existing design method of PSC girder bridges, according to total service loads, stress required tendon force at a time. Because this design method increases beam depth, design of long span is difficult. However, As UC girder stressing at difficult loading stages reduces sectional depth of PSC girder, both design and operation of long span bridges is possible. so, this study analyzes the effect of design parameter (Girder Strength, Girder Spacing, Span Length, Joint Strength) on the beam depth of IPC girder continuous bridges, and shows sectional depth of UC girder for design of long span bridges. According to analysis, when a continuous bridges of same length span is at strength of joint over strength of girder of 600kg/$cm^{2}$, a change of beam depth is observed and when a continuous bridges of different span length is at strength of joint below strength of girder of 600kg/$cm^{2}$, a change of beam depth is observed. In two case, a change of beam depth is mostly observed over strength of girder of 350kg/$cm^{2}$ according to analysis of deflection data, a continuous bridges of IPC girder is nearly satisfied.

  • PDF

A Consideration on Intermediate Diaphragm Spacing of Steel-Box Girder Bridges Including Distortion (뒤틀림을 고려한 강박스 거더교의 내부 다이아프램 간격에 관한 고찰)

  • Lim Da Soo;Han Kuem Ho;Park Nam Hoi;Kang Young Jong
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.522-530
    • /
    • 2003
  • Generally, diaphragms are installed in the box girder to prevent or decrease the distortion of the cross section. In engineering practice, diaphragms are spaced in 5m intervals without reasonable basis. the usual diaphragm type is solid-plate type. It is considered to be noneconomical design to the almost design engineers. In this paper, the parametric study was performed to present the design proposal about the diaphragm stiffness and spacing only in the single cell box girder. For that, the distortional warping normal stress, bending normal stress and transverse bending normal stress were analyzed using finite element program 'SMB' for the accurate structural analysis.

  • PDF

Stress Analysis of Semi-Rigid Frame (부분 강절 골조의 응력 해석)

  • 김선혜;김순철;이수곤
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.306-313
    • /
    • 1998
  • Contrary to reinforced concrete frames, the beams or girders found in actual steel frames are neither hinged nor fixed at their ends. Instead, they are usually restrained by the columns to which they are attached. Here in this paper, common finite element program for plane frame stress analysis is improved by including the effect of partial fixities of the girder ends. To include the effect of partial fixities of the girder ends, Kim's modified slope-deflection equation is adopted. The stress analysis results obtained by this proposed method are then compared with Kim's example. Finally, method of choosing the most economic girder section for a multi-story frame is suggested through the examples.

  • PDF

A Study for Stiffness Improvement Method with Use of Filled Concrete in Continued Steel Box Girder Bridge (강상자형 연속교에서 콘크리트재를 이용한 부모멘트 구간의 강성향상공법)

  • 구민세;이호경
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.10a
    • /
    • pp.69-78
    • /
    • 1999
  • The stiffness of slab concrete section is not considered as effective in the existing method of construction for continued steel box girder bridge. Using lifting system and filled concrete, it is possible to make stiffness of slab concrete section effective and improve stiffness of negative moment section. It was proved that the stress of upper flange in positive moment is significantly lower than case of existing method through the stress comparison. This stress difference made possible to rearrange flange thickness and as the result of this rearrangement, the amount of steel and height of girder can be reduced up to 13.23% and 11.5%.

  • PDF

Design Optimization on Diaphragm Stiffness and Spacing of Steel-Box Girder Bridges with a Single-Cell Section (단실단면을 갖는 강박스 거더교의 다이아프램의 강성과 간격에 관한 설계 최적화)

  • 임다수;박남회;한택희;강영종
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.133-144
    • /
    • 2003
  • Generally, diaphragms are installed in the box girder to prevent or decrease the distortion of tile cross section. In engineering practice, diaphragms are spaced in 5m intervals without reasonable basis. ANd the usual diaphragm type is solid-plate type. It is considered to be noneconomical design to the almost design engineers. In this paper, the parametric study was performed to present the design proposal about the diaphragm stiffness and spacing only in tire single cell box girder. For that, the distortional warping normal stress, bending normal stress and transverse bending normal stress were analyzed using finite element program 'SMB' for the accurate structural analysis.

  • PDF

Evaluation of Behavior of Direct Fixation Track and Track Girder Ends on Yeongjong Grand Bridge (영종대교 강직결 궤도 및 종형거더 단부의 거동 분석)

  • Choi, Jung-Youl;Chung, Jee-Seung;Kim, Jun-Hyung;Lee, Kyu-Yong;Lee, Sun-Gil
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study is to investigate the influence of train-induced end rotation of simple supported track girder on the performance of a direct fixation track system (DFTS) in Yeongjong grand bridge. In this study, the influences of deflection of a DFTS and track girder on dynamic rail-track girder interaction forces for the track girder ends currently employed in airport express lines were assessed by performing field tests using actual vehicles running along the service lines. Therefore, the dynamic displacement of rail and track girder and the fastener stress on the center and ends sections of DFTS were measured for two different trains (AREX and KTX) running in Yeongjong grand bridge. A three-dimensional finite element analysis (FEA) model using the time-history function based on the design wheel load was used to predict the train-induced track and track girder displacement, and the FEA and field test results were compared. The analytical results reproduced the experimental results well within about 3-7% difference in the values. Therefore, the FEA model of DFTS on track girder is considered to provide sufficiently reliable FEA results in the investigation of the behavior of DFTS. Using the analytical and experimental results, the influence of train-induced end rotation of simple supported track girder on the interaction behavior of rail and track girder installed on a simple supported track girder ends, i.e., upward displacement of rail-track girder and the fastener stress, was investigated. It was found that the train-induced end rotation effect of track girder was not significantly affected by the upward displacement of rails and the fastener stresses of track girder ends. Further, the interaction behavior of rail and track girder were similar to or less than that of the general railway bridge deck ends, nevertheless the vertical displacement of track was higher than that of conventional DFTS on the general railway bridge. From the results, the dynamic responses of the DFTS on track girder ends were not significantly affected by the safety and stability of DFTS ends.

A Study on the Flexural Behavior of Proposed Spliced PSC-I Type Girder (제안된 Spliced PSC-I형 거더의 휨거동에 관한 연구)

  • 심종성;오홍섭
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.13-23
    • /
    • 2000
  • In this study, an flexural test on half-scale spliced PSC-I girder was conducted to verify the efficiency of the long span spliced girder as suggested by the Korean Highway Design Specification. The experimental results showed that the specimens developed a complex failure mode due to flexural-compression and torsional stress. The cracking moment of each girder was higher the experiment than was calulated by the ACI and the ultimate strength were the almost same. To estimate the safety and the structural efficiency of the spliced girder, the proposed Yielding Resistance Index(YRI) and ductility index by American Concrete Institutes were used based on the energy concept. The proposed YRI defined the ratio of crack resisting energy and the total energy calculated from load-displacement relationship. Based on the analysis of YRI and ductility index, the flexural behavior of the spliced girder was found to be efficient. Through the experimental results, the structural behavior of proposed spliced PSC I-type girder for long span bridge was found to be more efficient than the exsisting PSC I-type girders.

Flexural Test for a Monolithic Holed Web Prestressed Concrete (HWPC) Girder

  • Han, Man-Yop;Jin, Kyung-Suk;Choi, Sok-Hwan
    • International Journal of Concrete Structures and Materials
    • /
    • v.4 no.2
    • /
    • pp.77-87
    • /
    • 2010
  • Prestressed concrete (PSC) I-type girders have been used for span length around up to 40 m in domestic region. PSC girders are very cost effective girder type and extending their lengths more than 50 m will bring large benefit in cost. A new design method was proposed by combining two notable design concept in order to extend the applicable span length in this study. First of all, several numbers of openings was introduced in the girder web, and half of the anchorage devices were moved into the openings. In this way, large compressive stress developed at end zone was reduced, and the portion of design load coming from self-weight was reduced as well. Secondly, prestressing force was introduced in the girder not once at the initial stage, but through multiple loading stages. A full scale girder with the length of 50 m with the girder depth of 2 m was fabricated, and a flexural test was conducted in order to verify the performance of newly developed girder. Test results showed that the new holed web design concept can provide a way to design girders longer than 50 meters with the girder height of 2 m.