• Title/Summary/Keyword: Gi Dae Seung

Search Result 174, Processing Time 0.029 seconds

Evaluation of Geotechnical Parameters Based on the Design of Optimal Neural Network Structure (최적의 인공신경망 구조 설계를 통한 지반 물성치 추정)

  • Park Hyun-Il;Hwang Dae-Jin;Kweon Gi-Chul;Lee Seung-Rae
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.9
    • /
    • pp.25-34
    • /
    • 2005
  • This paper proposes a selection methodology composed of neural network (NN) and genetic algorithm (GA) to design optimal NN structure. We combine the characteristics of GA and NN to reduce the computational complexity of artificial intelligence applications and increase the precision of NN' prediction in the design of NN structure. Genetic selection approach of design parameters of NN is introduced to obtain optimal NN structure. Analyzed results for geotechnical problems are given to evaluate the performance of the proposed hybrid methodology.

The Effect of Korean Medicine with Needle-embedding Therapy on a Lumbar Herniated Intervertebral Disc : A Case Report (요추 추간판 탈출증 환자에 대한 매선을 포함한 한의 복합치료의 효과 : 증례보고)

  • Hong, Seung Pyo;Bae, Ji Min;Kim, Dae Hun;Yang, Gi Young;Lee, Byung Ryul
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.219-224
    • /
    • 2016
  • Objectives : The purpose of this study was to report the clinical effects of needle-embedding acupuncture therapy combined with Korean medicine on a lumbar herniated intervertebral disc. Methods : We treated one patient with a lumbar herniated intervertebral disc with needle-embedding acupuncture therapy combined with Korean medical treatment. We checked the numeric rating scale(NRS), oswestry low back pain disability index(ODI) and straight leg raising test(SLRT). Results : In this case, the numeric rating scale decreased, while the straight leg raising test results improved. Conclusion : Needle-embedding acupuncture therapy could be effective for pain-reduction for a lumbar herniated intervertebral disc.

The Electron Temperature and Density Properties of Mixed Gases in ICP Lighting System : (Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe 및 Ne:Ar 혼합가스의 전자온도 및 전자밀도 특성)

  • Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee;Choi, Gi-Seung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.3
    • /
    • pp.156-160
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem and root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixed gas lamp improve firing voltage of Xe gas lamp. Purpose of this study is to understand ideal mixing-ratio of Ne:Xe and Ne:Ar gas by electron temperature and electron density for mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by single-Langmuir probe. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

Photoelectrochemical cells based on oxide semiconductors

  • Yun, Yeong-Dae;Baek, Seung-Gi;Kim, Ju-Seong;Kim, Yeong-Bin;Jo, Hyeong-Gyun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.50.2-50.2
    • /
    • 2018
  • The demand for steady and dependable power sources is very high in the field of sustainable energy because of the limited amount of fossil fuels reserves. Among several sustainable alternatives, solar energy may be the most efficient solution because it constitutes the largest renewable energy source. So far, the only practical way to store such large amounts of energy has been to use a chemical energy carrier likewise a fuel. In various solar energy to power conversion systems, the photoelectrochemical (PEC) splitting of water into hydrogen and oxygen by the direct use of solar energy is an ideal process. It is a renewable method of hydrogen production integrated with solar energy absorption and water electrolysis using a single photoelectrode. Previous studies on photoelectrode films for PEC water splitting cells have been mainly focused on synthesizing oxide semiconductors with wide band gaps, such as TiO2(3.2eV), WO3(2.8eV), and Fe2O3(2.3eV). Unfortunately, these pristine oxide photoanodes without any catalysts have relatively low photocurrent densities because of the inherent limitation of insufficient visible light absorption due to the wide bandgap. Specifically, there is a tradeoff between high photocurrent and photoelectrochemical corrosion behavior, which is representative of figures of meritf or PEC materials.

  • PDF

Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp (무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성)

  • Lee, Joo-Ho;Choi, Gi-Seung;Kim, Nam-Goon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1273-1274
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF

Consideration in the Interpretation of the Daeseunggi-tang (대승기탕의 방론에 대한 고찰)

  • Han, Sang-Gon;Seo, Young-Bae;Jeong, Gi-Hoon
    • Herbal Formula Science
    • /
    • v.24 no.3
    • /
    • pp.195-211
    • /
    • 2016
  • Objectives : The purpose of this study was to investigate the interpretation of the Daeseunggi-tang(DST) in order to obtain the evidence for clinical applications.Methods and Results : We have analyzed the interpretation on the DST through translations and comparisons based on classic books about the oriental medical prescriptions.Conclusion : 1. 'Dae(大)' in DST means 'strong symptoms' or 'strong efficacy'. 'Seung(承)' in DST means 'smooth (順)', 'attach(連)' and 'serve(奉)'. 2. The main pathogenesis of DST's syndrome are heat binding(熱結)·qi stagnation(氣滯). 3. The main areas where disease pattern of DST is 'Yang brightness(陽明)'. It is also associated with 'Lesser yin (少陰)', 'Qi aspect(氣分)·Blood aspect(血分)' and 'Triple Energizer(三焦)'. 4. Laxative the Rhei Radix et Rhizoma(大黃) is sovereign medicinal(君藥) of DST, because of removing the heat binding(熱結) and the heat that spread throughout the body.

Sustainable Vibration Energy Harvesting Based on Zr-Doped PMN-PT Piezoelectric Single Crystal Cantilevers

  • Moon, Seung-Eon;Lee, Sung-Q;Lee, Sang-Kyun;Lee, Young-Gi;Yang, Yil-Suk;Park, Kang-Ho;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • In this paper, we present the results of a preliminary study on the piezoelectric energy harvesting performance of a Zr-doped $PbMg_{1/3}Nb_{2/3}O_3-PbTiO_3$ (PMN-PZT) single crystal beam. A novel piezoelectric beam cantilever structure is used to demonstrate the feasibility of generating AC voltage during a state of vibration. The energy-harvesting capability of a PMN-PZT beam is calculated and tested. The frequency response of the cantilever device shows that the first mode resonance frequency of the excitation model exists in the neighborhood of several hundreds of hertz, which is similar to the calculated value. These tests show that several significantly open AC voltages and sub-mW power are achieved. To test the possibility of a small scale power source for a ubiquitous sensor network service, energy conversion and the testing of storage experiment are also carried out.

Health Monitoring System based on Wireless Sensor Network for Weapon Asset (무선 센서 네트워크 기반 무기 자산 건전성 모니터링 시스템)

  • Yoon, Kyung-Hyo;Lee, Seung-Il;Lee, Jin-Young;Ha, Sung-Gi;You, Chang-Seok;Kim, Seong-Ryul;Seo, Dae-Wha
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1C
    • /
    • pp.97-108
    • /
    • 2012
  • This paper introduces a health monitoring system based on a wireless sensor network for weapon asset. This system can estimate the remaining lifetime and decide what should be done and when should it be done using the environmental conditions such as temperature, humidity and shock for weapon assets by sensor tag. And we describes its operating scenario and routing method for this system. Finally we introduce the developments of the sensor tag, portable reader, gateway and monitoring server.

The Operation Method of Coordinated Multi-point Transmission/Reception in Cloud Base Station (클라우드 기지국에서의 조정 다중점 송수신 운용 방법)

  • Park, Soon-Gi;Shin, Yeon-Seung;Song, Pyeong-Jung;Kim, Dae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.10
    • /
    • pp.775-784
    • /
    • 2013
  • Mobile operators are considering a variety of technical measures to cope with the explosion of data while reducing TCO(Total Cost of Ownership) of their networks. In this paper, to investigate the possibility about one of such technical measures, system level simulation to evaluate the performance of the capacity and mobility was performed in cloud base station structure to apply coordinated multi-point transmission and reception. As a result, we find out that system capacity and mobility performance may be improved according to the scale and application area of cloud base station with the operation of coordinated multi-point transmission and reception, and these mutual causality can provide practical guidelines to mobile network's operation.

Properties of Temperature and Brightness Applied on Frequency in Electrodeless Fluorescent Lamp (무전극 형광램프의 주파수 변화에 따른 온도 및 광속 특성)

  • Lee, Joo-Ho;Choi, Gi-Seung;Kim, Nam-Goon;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1733-1734
    • /
    • 2006
  • In recent, it became necessary to develop the technology about electrodeless fluorescent lamp according to demand of the electrodeless fluorescent lamp system that used higher efficiency and advantage of long lifetime. Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. An electric power efficiency of electrodeless fluorescent lamp has big relative property of gas in lamp, gas pressure, lamp formation, ingredients of magnetic substance and shape and action frequency etc. We used magnetic substance that open self-examination material of electrodeless fluorescent lamp antenna. Ferrite that is used in this experiment was Mn-Zn type. We have examined temperature and flux characteristic by frequency. Considering using frequency 2.65[MHz], Frequency was changed from 2.05[MHz] to 3.05[MHz] to recognize flux and temperature change of lamp. I used LMS(Lighting Measurement System) to measure flux and IR Camera to measure temperature of lamp.

  • PDF