• Title/Summary/Keyword: Germany Freiburg

Search Result 6, Processing Time 0.028 seconds

A Case Study on Environment Friendly Housing in Germany -Focused on Freiburg Vauban Housing Complex- (독일친환경주거사례연구 -프라이부르크 보봉(Vauban)주거단지를 중심으로-)

  • Kwak, Yu-Mi;Cho, Jeong-Hyun;Choi, Jung-Shin
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2005.11a
    • /
    • pp.243-248
    • /
    • 2005
  • As environmental Problems are increasing, many attempts to solve problems and preserve environment are appearing around the world. Not only in construction, but also dwelling life, residents attend many activities to improve environmental problems. Ecological development example of Freiburg in Germany was focused in this study to show the direction of development of environmental friendly housing complex in Korea. The target of study is Vauban Housing Complex of Freiburg in Germany. The study methods are literature study and field trip. Contents of the study include 1) formation process of the complex 2) physical environment of the complex 3) environmental friendly factors of the complex 4) environmental friendly life style of the residents, etc. Result of this study is as follows. Vauban Housing Complex was remodeled from the existed army buildings by residents themselves through education and negotiations. Residents' life satisfaction and housing adaptation level were high on the whole. The principle of the complex formation was use of natural feature itself in maximum against developing in minimum. For instance, construction materials, energy saving, resources saving were planned and used carefully. The residents led community successfully according to environmental friendly life principles. In conclusion, the persistent study on environmental components is necessary that is suitable to Korean situation.

  • PDF

A Study on the Environmental Characteristics of the Pedestrian District in Freiburg, Germany - Focusing on Identity as a Historical City as related to the Waterscape and Paving Environments - (독일 프라이부르크시 보행자전용구역의 환경특성 - 수경 및 포장환경을 통해 본 역사적 정체성을 중심으로 -)

  • Hong, Youn-Soon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.2
    • /
    • pp.64-74
    • /
    • 2010
  • Freiburg, as the German Capital of the Environment, is well known to Koreans, and relationships with Korean cities are deeply extended. This study attempts to grasp the features of the historical and cultural environment in Freiburg's old town center pedestrian district through the investigation of the historical value of environmental elements and the way they are transmitted along with the components of city identity. Through the literature studies confirms that. The main canal in Freiburg, called Gewerbeknale, is valued both for its existence during the city construction period and for being an infrastructure to supply water to the Bachle(small urban canal) and Brunnen(fountain). In spite of a recipient environment in the middle of the 19th century, the traditional mosaic pavement has a new value as an mediator between citizens and the environment through the adaptations that have occurred in the city. This study has verified the dialectical repetition of crisis and conquest through the historical succession of environmental elements. The historical continuance of environmental elements has a strong influence on the acquisition of sameness and Individuality in city identity factors. The result of this study recommends the historical value of environmental elements that have survived in the urban environment, and verifies the necessity of a concrete strategy for preservation and related practical efforts.

The Third Version of the Copenhagen Psychosocial Questionnaire

  • Burr, Hermann;Berthelsen, Hanne;Moncada, Salvador;Nubling, Matthias;Dupret, Emilie;Demiral, Yucel;Oudyk, John;Kristensen, Tage S.;Llorens, Clara;Navarro, Albert;Lincke, Hans-Joachim;Bocerean, Christine;Sahan, Ceyda;Smith, Peter;Pohrt, Anne
    • Safety and Health at Work
    • /
    • v.10 no.4
    • /
    • pp.482-503
    • /
    • 2019
  • Introduction: A new third version of the Copenhagen Psychosocial Questionnaire (COPSOQ III) has been developed in response to trends in working life, theoretical concepts, and international experience. A key component of the COPSOQ III is a defined set of mandatory core items to be included in national short, middle, and long versions of the questionnaire. The aim of the present article is to present and test the reliability of the new international middle version of the COPSOQ III. Methods: The questionnaire was tested among 23,361 employees during 2016-2017 in Canada, Spain, France, Germany, Sweden, and Turkey. A total of 26 dimensions (measured through scales or single items) of the middle version and two from the long version were tested. Psychometric properties of the dimensions were assessed regarding reliability (Cronbach α), ceiling and floor effects (fractions with extreme answers), and distinctiveness (correlations with other dimensions). Results: Most international middle dimensions had satisfactory reliability in most countries, though some ceiling and floor effects were present. Dimensions with missing values were rare. Most dimensions had low to medium intercorrelations. Conclusions: The COPSOQ III offers reliable and distinct measures of a wide range of psychosocial dimensions of modern working life in different countries; although a few measures could be improved. Future testing should focus on validation of the COPSOQ items and dimensions using both qualitative and quantitative approaches. Such investigations would enhance the basis for recommendations using the COPSOQ III.

Diagnostic reference levels in intraoral dental radiography in Korea

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Jung, Yun-Hoa;Yoon, Suk-Ja;Lee, Jae-Seo
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.237-242
    • /
    • 2012
  • Purpose: The objectives of this study were to survey the radiographic exposure parameters, to measure the patient doses for intraoral dental radiography nationwide, and thus to establish the diagnostic reference levels (DRLs) in intraoral dental X-ray examination in Korea. Materials and Methods: One hundred two intraoral dental radiographic machines from all regions of South Korea were selected for this study. Radiographic exposure parameters, size of hospital, type of image receptor system, installation duration of machine, and type of dental X-ray machine were documented. Patient entrance doses (PED) and dose-area products (DAP) were measured three times at the end of the exit cone of the X-ray unit with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for adult mandibular molar intraoral dental radiography, and corrections were made for room temperature and pressure. Measured PED and DAP were averaged and compared according to the size of hospital, type of image receptor system, installation duration, and type of dental X-ray machine. Results: The mean exposure parameters were 62.6 kVp, 7.9 mA, and 0.5 second for adult mandibular molar intraoral dental radiography. The mean patient dose was 2.11 mGy (PED) and 59.4 $mGycm^2$ (DAP) and the third quartile one 3.07 mGy (PED) and 87.4 $mGycm^2$ (DAP). Doses at university dental hospitals were lower than those at dental clinics (p<0.05). Doses of digital radiography (DR) type were lower than those of film-based type (p<0.05). Conclusion: We recommend 3.1 mGy (PED), 87.4 $mGycm^2$ (DAP) as the DRLs in adult mandibular molar intraoral dental radiography in Korea.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge (가상쐐기와 기존쐐기의 물리적 특성 비교)

  • Choi Dong-Rak;Shin Kyung Hwan;Lee Kyu Chan;Kim Dae Yong;Ahn Yong Chan;Lim Do Hoon;Kim Moon Kyun;Huh Seung Jae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : We have compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. Materials and Methods : We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60$^{\circ}$) using 6- and 15MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a 15cm${\times}$20cm radiation field size at the depth of loom. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was 15cm H20cm and a polystyrene phantom was used. Results : For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%) , respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5$^{\circ}$ . Suface dose with physical wedge was reduced by maximum 20% (x-ray beam :6 MV, wedge angle:45$^{\circ}$, 550: 80 cm) relative to one with virtual wedge or without wedge. Conclusions : Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using physical wedge.

  • PDF