하천-충적대수층계의 강변여과수를 열원으로 이용하는 지하수 열펌프 시스템의 계절별 입구온도와 효율성 평가 (Seasonal Variations of EWT and COP of GWHP System Using the Bank Infilterated Water from Stream-Alluvial Aquifer System)

  • 한찬;전재수;윤운상;한혁상;한정상
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.39-51
    • /
    • 2007
  • Unconsolidated and permeable alluvial deposit composed of sand and gravel is distributed along the fluvial plain at the Iryong study area. Previous studies on the area show that a single alluvial well can produce at least 1,650m3d-1 of bank infilterated shallow groundwater(BIGW) from the deposit. This study is aimed to evaluate and simulate the influence that seasonal variation of water levels and temperatures of the river have an effect on those of BIGW under the pumping condition and also to compare seasonal variation of COPs when indirectly pumped BIGW or directly pumped surface water are used for a water to water heat pump system as an heat source and sink using 3 D flow and heat transport model of Feflow. The result shows that the magnitude influenced to water level of BIGW by fluctuation of river water level in summer and winter is about 48% and 75% of Nakdong river water level separately. Seasonal change of river water temperature is about $23.7^{\circ}C$, on other hand that of BIGW is only $3.8^{\circ}C$. The seasonal temperatures of BIGW are ranged from minimum $14.5^{\circ}C$ in cold winter(January) and maximum $18.3^{\circ}C$ in hot summer(July). It stands for that BIGW is a good source of heat energy for heating and cooling system owing to maintaining quite similar temperature($16^{\circ}C$) of background shallow groundwater. Average COPh in winter time and COPc in summer time of BIGW and surface water are estimated about 3.95, 3.5, and about 6.16 and 4.81 respectively. It clearly indicates that coefficient of performance of heat pump system using BIGW are higher than 12.9% in winter time and 28.1% in summer time in comparision with those of surface water.

  • PDF

지열 시스템의 원예시설과 축사시설 적용에 관한 연구 (A Study on Applying the Ground Source Heat Pump System in Greenhouse and Livestock Facility)

  • 장재철;강은철;송준익;김지영;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권2호
    • /
    • pp.1-6
    • /
    • 2009
  • In this paper, RETScreen program model has been investigated to predict the economic analysis for greenhouse and livestock facility. Load calculation result was 35.2[kW] of greenhouse and the calculation result of livestock facility was 35.5[kW]. Also, a case study of the RETScreen program indicated that the equity payback is 6.9 years for a greenhouse facility and the equity payback is 9.5 years for a livestock facility.

  • PDF

착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술 (Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition)

  • 전창덕
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.573-577
    • /
    • 2013
  • 히트펌프는 에너지 효율이 높고, 지열, 폐열, 공기열 등 다양한 열원 사용이 가능하기 때문에 보급이 빠르게 확대되고 있다. 공기를 열원으로 이용하는 공랭식 히트펌프의 경우는 실외기 표면에 형성되는 서리를 제거하기 위해 제상운전이 요구된다. 일반적으로 사용하는 역사이클(reverse cycle) 제상운전 방법은 연속난방이 불가능하며 이로 인해 성능계수가 감소하는 원인이 된다. 본 연구에서는 실외기 코일용 휜-관 열교환기를 3열로 구성하고 난방과 제상이동시에 가능하도록 일정시간 간격으로 열교환기의 한 개의 열을 응축기로, 나머지 열은 증발기로 교번 운전을 수행하여 KS C 9306에 규정된 제상-난방 시험조건(건구온도 $2^{\circ}C$, 습구온도 $1^{\circ}C$)에서 최소 180분 이상 연속난방이 가능함을 실증하였으며 역사이클 제상방법을 사용하는 일반적인 히트펌프 대비 COP가 약 20% 향상됨을 알 수 있었다.

강변여과수와 천부 지하수를 이용하는 지하수 열펌프시스템의 적정유량 (Optimum Pumping Rates of Ground-Water Heat Pump System Using Groundwater or Bank Infilterated Water)

  • 한정상;한혁상;한찬;전재수;김형수
    • 자원환경지질
    • /
    • 제40권6호
    • /
    • pp.833-841
    • /
    • 2007
  • 지하수열펌프시스템(GWHP)은 지원열펌프시스템(GSHP)가운데 성능이 가장 우수하며 저온의 천부지하수열을 이용하는 시스템이다. GWHP시스템은 지중연결 열펌프시스템(GCHP)에 비해 최대 블록부하와 전 시스템 성능에 부합되는 지하수유량을 기준으로 하여 설계를 하며 최적 지하수유량은 해당지역의 지하수온도, 판형열교환기의 규격과 전체펌프와 배관류의 전 양정고에 따라 결정한다. 대체적으로 전형적인 빌딩루프순환수의 필요유량은 1RT당 $9.5{\sim}11.4lpm$ 정도인데 비해 GWHP시스템이 필요로 하는 최적 지하수유량은 이보다 꿜씬 적은 $3.8{\sim}9.5lpm$정도이다.

현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구 (The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles)

  • 박용부;남유진;심영종;손정락
    • 토지주택연구
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2012
  • 최근, 지열 냉난방 시스템의 초기 공사비를 절감하기 위해 연구되고 있는 에너지 파일의 열교환량을 산정하기 위해 2종류(부속연결형, 슬링키형)의 현장타설말뚝형(PRD, 시공심도 4.5m, 직경 1,200mm) 에너지 파일을 시험시공하고 수치 시뮬레이션에 의해 효율을 상호 비교하였다. 상호 비교결과에 의하면 지중 교환량은 운전시작과 함께 채열에 의한 지중온도의 저하에 의해 점점 감소하였고 부속연결형의 평균 열원수의 온도차는 난방운전에서 $0.37^{\circ}C$, 냉방운전에서 $0.34^{\circ}C$로 나타났다. 또, 부속연결형의 난방운전시 열교환량 231.4W/m보다 냉방운전의 방열량은 252.2W/m로서 9% 높았고 슬링키형은 난방 기간 평균 열교환량이 168.0W/m로 부속연결형에 비해 약 27% 낮은 열교환량을 얻었다.

강변여과수(충적층 및 하상) 열자원 활용 기술 개발 (Development of Technology on Water Thermal Energy Utilization of Riverbank(including Alluvial and Riverbed deposits) Filtration)

  • 김형수;서민우;정우성;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.591-594
    • /
    • 2005
  • Geothermal energy becomes to be one of the promising energy sources. In this study, technology using water thermal energy from riverbank filtration system(including alluvial and riverbed deposit) is reviewed and checked as an energy resources. The objects of this study are (1) long-term monitoring of alluvial and riverbed sites, (2) preliminary design of cooling and heating system at riverbank filtration facility, and (3) calculation of potential groundwater heat energy, including riverbank filtration system. Measuring data of alluvial and riverbank filtration show slight fluctuations comparing to temperature of atmospheric air which indicates that groundwater obtained from the riverbank filtration system have a sufficient potential as a source of cooling and heating energy.

  • PDF

지중 유효 열전도도의 지역별 분포 (A Study on Regional Distribution of the Ground Effective Thermal Conductivity)

  • 공형진;권순기;지승규
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제4권1호
    • /
    • pp.43-47
    • /
    • 2016
  • 지열 히트펌프 시스템은 환경 친화적이고 에너지 절감 시스템으로 알려져 있다. 특히 지중 열교환기는 초기투자비와 시스템 성능을 결정하는 매우 중요한 요소다. 수직형 지열 시스템 설계를 위해서는 현장 열응답 테스트를 통해 지중 유효 열저항을 고려해야 한다. 본 연구에서는 지열이용검토서를 통해 접수된 전국의 지중 열전도도를 지역별로 분석하였다. 전국 평균 지중 열전도도는 2.56 W/mK로 분석되었다. 지중 열전도도가 가장 높은 지역은 서울로 평균 2.68 W/mK이고, 가장 낮은 지역은 부산으로 2.28 W/mK다. 또한 해안을 접하고 있는 지역의 열전도도는 전국 평균에 비해 약 30% 낮다.

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

무선 전자식 장비를 이용한 지중열전도도 측정 기술 (Ground Thermal Conductivity Test with A Wireless Probe)

  • 김지영;이의준;장기창;강은철;고건혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2381-2384
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

  • PDF

지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교 (Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions)

  • 김진성;송성호;정교철
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 국내에서 열물성에 관한 연구는 지역별, 암종별 열물성 파악을 위주로 진행되었으나, 지열냉난방시스템 설계 시에 실시하는 TRT (thermal response test)의 열전도도와 차이가 크게 나타남에 따라 본 연구에서는 지하수 부존량이 풍부한 지역에서 시료를 통한 열전도도와 TRT를 통한 열전도도를 비교하였다. 토양 시료의 열전도도는 1.32 W/m-K, 암석 시료의 열전도도는 2.88 W/m-K로 나타났으며, TRT로 측정된 열전도도는 3.13 W/m-K로 나타나 암석 시료보다 약 10% 정도 높게 나타났다. 연구지역은 지하수가 풍부하고 0.01의 수리경사를 가지고 있어 이 차이는 지하수 흐름에 의한 영향이라고 판단된다. 라인소스(line source) 이론에 따르면 TRT는 지반의 순수한 열전도도를 산정하는 것이 목적이므로, 국내 SCW (standing column well)형의 TRT는 라인소스 이론에 적합하지 않으며 지열냉난방시스템 설계 시에는 시료를 통한 열전도도값을 사용하는 것이 타당하다고 판단된다.