Ground Thermal Conductivity Test with A Wireless Probe

무선 전자식 장비를 이용한 지중열전도도 측정 기술

  • 김지영 (한한국에너지기술연구원 재생에너지연구부 지열에너지연구센터) ;
  • 이의준 (한국에너지기술연구원 재생에너지연구부) ;
  • 장기창 (한국에너지기술연구원 재생에너지연구부 지열에너지연구센터) ;
  • 강은철 (한국에너지기술연구원 재생에너지연구부 지열에너지연구센터) ;
  • 고건혁 (한국에너지기술연구원 재생에너지연구부 지열에너지연구센터)
  • Published : 2008.11.05

Abstract

The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic Response Test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless probe for hi-speed k determination was introduced in this paper. This technique using a wireless probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. As a result, the electronic wireless probe can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of local heat flow, etc.

Keywords