• 제목/요약/키워드: Geometry of Electrode

검색결과 144건 처리시간 0.027초

프랙탈 기하학을 이용한 부분적으로 비활성된 전이금속 산화물 전극을 통한 리튬 이동에 관한 연구: 몬테 카를로 시뮬레이션을 이용한 전류 추이 곡선의 해석 (Lithium Transport through Partially Inactive Transition Metal Oxide Electrode in Terms of Fractal Geometry: Current Transient Analysis by Monte Carlo simulation)

  • 정규남;변수일
    • 한국전기화학회:학술대회논문집
    • /
    • 한국전기화학회 2005년도 춘계총회 및 학술발표회
    • /
    • pp.53-53
    • /
    • 2005
  • PDF

Determination of energetically preferable Au-S contact atomic structure in stretched single-molecule junctions

  • Ko, Kwan Ho
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제3회(2014년)
    • /
    • pp.409-411
    • /
    • 2014
  • Based on the first-principles computations, the nature of the microscopic geometry of the molecule-electrode contacts was addressed. The single-molecule junction was prepared by connecting hexanediothiolate (HDT) to Au(111) electrodes via one, two, and three Au adatoms having coordination number of one (CN1), two (CN2), and, three (CN3), respectively. The contact atomic structure and energy of the stretched Au-HDT-Au junction was observed. The analysis revealed that the contact geometry with lowest coordination number (CN1) is energetically more stable than CN2 and CN3.

  • PDF

전기임피던스 단층촬영법을 위한 단순화된 매모그래피 구조의 모델 (A Model of a Simplified Mammography Geometry for Breast Cancer Imaging with EIT)

  • 최명환
    • 산업기술연구
    • /
    • 제26권B호
    • /
    • pp.221-226
    • /
    • 2006
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present "gold standard" for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. This paper presents a forward model of a simplified mammography geometry for EIT imaging. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and Validated by experiment using a phantom tank.

  • PDF

광폭 전기집진기의 집전특성에 관한 연구 - I. 집진판 간격과 방전극의 영향 -

  • 김용진;하병길;정상현;홍원석;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.939-946
    • /
    • 2001
  • This study investigates the electrical and collection characteristics of a wide plate spacing electrostatic precipitator (ESP), using a pilot-scale one. Electrical operating characteristics and collection efficiency were measured for various shapes of discharge electrodes. The collection plate spacing ranged from 300 to 550 mm. Results of electrical characteristic and collection efficiency tests as a function of collection plate spacing, discharge electrode type, applied voltage, and particle diameter were obtained. Increasing the collection plate pitch and altering the corona electrode geometry was found to increase the collection efficiencies without increasing input power requirement. The best efficiency is achieved for the discharge electrode of twisted pin type.

  • PDF

Iron(II) Tris(3-bromo-1,10-phenanthroline) Complex: Synthesis, Crystal Structure and Electropolymerization

  • Lee, Kyeong-Jong;Yoon, Il;Lee, Shim-Sung;Lee, Bu-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.399-403
    • /
    • 2002
  • The complex of iron(II) tris(3-Br-phen) (3-Br-phen; 3-bromo-1,10-phenanthroline) was prepared as a precursor of electropolymerization and the crystal structure of [Fe(3-Br-phen)3]($PF_6$)2${\cdot}$CH3CN with a distorted octahedral geometry has been investigated. The reductive electropolymerization of $>[Fe(3-Br-phen)3]^{2+}$ complex onto the surface of a glassy carbon electrode and indium tin oxide (ITO) optically transparent electrode were performed in acetonitrile at room temperature. Thin film of poly-$>[Fe(3-Br-phen)3]^{2+}$ formed was adherent, electroactive and stably deposited on a glassy carbon disk electrode. The thin metallopolymeric film formed was also confirmed by absorption spectroscopy.

A Dual In-Plane Electrode Structure for Better Brightness in a Helix-Deformed FLCD

  • You, Doo-Hwan;Lee, Sin-Doo;Lee, Ju-Hyun;Na, Do-Jun
    • Journal of Information Display
    • /
    • 제2권1호
    • /
    • pp.1-4
    • /
    • 2001
  • We propose a dual in-plane parallel electrode structure of a vertical configuration of a helix-deformed ferroelectric liquid crystal (HDFLC) mode for better brightness than a single in-plain electrode case. This structure provides high brightness in addition to the analog gray scale capability, fast response, and wide-viewing characteristics. In contrast to a conventional HDFLC in a planar geometry, smectic layers arrange themselves parallel to the substrates and thus extremely uniform alignment of molecules in a large area is naturally achieved in our new configuration.

  • PDF

Survival of the Insulator under the electrical stress condition at cryogenic temperature

  • Baek, Seung-Myeong;Kim, Sang-Hyun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.10-14
    • /
    • 2013
  • We have clearly investigated with respect to the survival of the insulator at cryogenic temperature under the electrical stress. The breakdown and voltage-time characteristics of turn-to-turn models for point contact geometry and surface contact geometry using copper multi wrapped with polyimide film for an HTS transformer were investigated under AC and impulse voltage at 77 K. Polyimide film (Kapton) 0.025 mm thick is used for multi wrapping of the electrode. As expected, the breakdown voltages for the surface contact geometry are lower than that of the point contact geometry, because the contact area of the surface contact geometry is lager than that of the point contact geometry. The time to breakdown t50 decreases as the applied voltage is increased, and the lifetime indices increase slightly as the number of layers is increased. The electric field amplitude at the position where breakdown occurs is about 80 % of the maximum electric field value. The relationship between survival probability and the electrical stress at cryogenic temperature was evident.

Characterization of a LSCF/GDC Cathode Composite in Solid Oxide Fuel Cells Using Impedance Spectroscopy

  • Hwang, Jin-Ha;Lee, Byung-Kook
    • 한국세라믹학회지
    • /
    • 제42권12호
    • /
    • pp.793-799
    • /
    • 2005
  • A composite cathode of LSCF$(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.8}O_3)\;and\;GDC\; (Gd_2O_3-doped\;CeO_2:Ce_{0.9}Gd_{0.1}O_{1.95_})$ was characterized in terms of an electrode response, using a point contact in an Yttria-Stabilized Zirconia (YSZ) electrolyte incorporated into AC two-point impedance spectroscopy. The point-contacted configuration amplifies the responses occurring near the YSZ/cathode interface through the aligned point contact on the planar LSCF/GDC electrode. The point contact interface increases the bulk resistance allowing the estimation of the point contact geometry and resolving the electrode-related responses. The resultant impedance spectra are analyzed through an equivalent circuit model constructed by resistors and constant phase elements. The bulk responses can be resolved from the electrode-related portions in terms of spreading resistance. The electrode-related polarizations are measured in terms of temperature and oxygen partial pressure. The modified impedance spectroscopy is discussed in terms of methodology and analytical aspects, toward resolving the electrode-polarization issues in solid oxide fuel cells.

전극의 기하학적 형상이 전기비저항 탐사에 미치는 영향: 수치 해석 연구 (Influence of electrode geometry on electrical resistivity survey: Numerical study)

  • 김태영;이승훈;류희환;정성훈
    • 한국터널지하공간학회 논문집
    • /
    • 제25권2호
    • /
    • pp.101-120
    • /
    • 2023
  • 전기비저항 탐사 방법은 매질의 표면에 관입된 두 전극의 전위차와 전류와의 관계를 통해 전기 저항을 측정하고, 형상 계수를 이용하여 매질의 고유한 특성인 전기비저항을 계산한다. 현장 및 실대형 크기의 전기비저항 실험은 전극과 매질 사이의 접촉 면적이 적고, 전극 간 거리가 충분하기 때문에 계산상 편의를 위해서 동일한 표면적을 가진 반구형으로 치환하여 전기비저항을 산정한다. 하지만, 실내 소규모 크기의 전기비저항 실험은 전극의 지오메트리(전극의 관입 깊이, 전극사이의 거리, 전극의 길이와 반지름 크기)로 인해서, 등전위면과 전류 흐름이 달라지게 되므로, 궁극적으로 전기비저항값의 오차를 야기한다. 본 연구는 기존 연구에서 유도된 4가지 전극 형상(반구, 원기둥, 반구형 팁을 가진 원기둥, 콘형 팁을 가진 원기둥)에 따른 전기 저항 이론식을 정리하고, 전극 형상을 고려한 전기 저항 수치 해석을 실시하였으며, 이론식과 수치 해석 결과들의 비교를 통해서 개발된 수치 해석 모듈을 검증하였다. 또한, 각 전극 형상에 따른 전극 주변과 전극사이에 형성된 전기 저항 분포를 분석하였다. 추가적으로, 현장 전기비저항 탐사에서 주로 사용되는 콘형 팁을 가진 원기둥 전극의 전기적 특성에 따른 전류 흐름 분포를 고찰하였다.