• 제목/요약/키워드: Geometric quality

검색결과 410건 처리시간 0.025초

주상절리를 활용한 텍스타일 패턴디자인과 타이벡 패션상품 개발 (Development of Tyvek Fashion Product and Textile Pattern Design based on Columnar Joint)

  • 허승연
    • 한국의상디자인학회지
    • /
    • 제25권3호
    • /
    • pp.127-141
    • /
    • 2023
  • The purpose of this study is to develop a textile pattern design using the columnar joints motif and a Tyvek fashion clutch bags using it. As a research method, first, through a literature review, columnar joint and Tyvek are understood, and design cases were considered. Second, through a survey, the purchase perception and design preference of columnar joints cultural products were analyzed. Third, based on the results of the survey on color and print, the pattern design for each type of columnar joint were developed, and the uv-printed Tyvek clutch bag was developed. The results of this study are as follows. First, the reason why the public was not attracted to the purchase of cultural products was dissatisfaction with practicality, price adequacy, and aesthetics. Therefore, it was analyzed that quality, practicality, price, carry-on storage, collection value, and casualness, as well as aesthetic design were important factors for purchasing factors pursued by consumers. Second, consumers preferred small goods the most for cultural products, and they pursued the use of colorful and contrasting colors, modern and geometric patterns, and eco-friendly materials, such as Tyvek. Third, columnar joint can be classified into three cross sections and four arrangements. The design unit of the columnar joint could be expressed as a hexagonal column, and 12 different pattern designs could be developed according to the cross sections and arrangements type. In addition, it was found that it was easy to produce fashion products suitable for the sensibility of modern people by utilizing Tyvek materials.

지도 일반화 알고리듬의 임계값 설정에 따른 소축척 지도 제작의 효용성 연구 (A Study on the Effectiveness of Small-scale Maps Production Based on Tolerance Changes of Map Generalization Algorithm)

  • 김화경;류재학;허지용;신용태
    • 한국IT서비스학회지
    • /
    • 제22권5호
    • /
    • pp.71-86
    • /
    • 2023
  • Recently, various geographic information systems have been used based on spatial information of geographic information systems. Accordingly, it is essential to produce a large-scale map as a small-scale map for various uses of spatial information. However, maps currently being produced have inconsistencies between data due to production timing and limitations in expression, and productivity efficiency is greatly reduced due to errors in products or overlapping processes. In order to improve this, various efforts are being made, such as publishing research and reports for automating domestic mapping, but because there is no specific result, it relies on editors to make maps. This is mainly done by hand, so the time required for mapping is excessive, and quality control for each producer is different. In order to solve these problems, technology that can be automatically produced through computer programs is needed. Research has been conducted to apply the rule base to geometric generalization. The algorithm tolerance setting applied to rule-based modeling is a factor that greatly affects the result, and the level of the result changes accordingly. In this paper, we tried to study the effectiveness of mapping according to tolerance setting. To this end, the utility was verified by comparing it with a manually produced map. In addition, the original data and reduction rate were analyzed by applying generalization algorithms and tolerance values. Although there are some differences by region, it was confirmed that the complexity decreased on average. Through this, it is expected to contribute to the use of spatial information-based services by improving tolerances suitable for small-scale mapping regulations in order to secure spatial information data that guarantees consistency and accuracy.

Restoring Turbulent Images Based on an Adaptive Feature-fusion Multi-input-Multi-output Dense U-shaped Network

  • Haiqiang Qian;Leihong Zhang;Dawei Zhang;Kaimin Wang
    • Current Optics and Photonics
    • /
    • 제8권3호
    • /
    • pp.215-224
    • /
    • 2024
  • In medium- and long-range optical imaging systems, atmospheric turbulence causes blurring and distortion of images, resulting in loss of image information. An image-restoration method based on an adaptive feature-fusion multi-input-multi-output (MIMO) dense U-shaped network (Unet) is proposed, to restore a single image degraded by atmospheric turbulence. The network's model is based on the MIMO-Unet framework and incorporates patch-embedding shallow-convolution modules. These modules help in extracting shallow features of images and facilitate the processing of the multi-input dense encoding modules that follow. The combination of these modules improves the model's ability to analyze and extract features effectively. An asymmetric feature-fusion module is utilized to combine encoded features at varying scales, facilitating the feature reconstruction of the subsequent multi-output decoding modules for restoration of turbulence-degraded images. Based on experimental results, the adaptive feature-fusion MIMO dense U-shaped network outperforms traditional restoration methods, CMFNet network models, and standard MIMO-Unet network models, in terms of image-quality restoration. It effectively minimizes geometric deformation and blurring of images.

Focus DWI 검사에서 중심축 이동에 따른 화질 평가 (The Evaluation of Imaging Quality Depending the Shift of the Central Axis in FOCUS DWI Investigation)

  • 김용화;정문택;최남길
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.631-636
    • /
    • 2018
  • 기존의 자기공명영상검사에서 문제점으로 지적되어 왔던 위상부호화 방향에서의 긴 판독시간과 낮은 대역폭과 함께 기하학적 왜곡의 경향이 있어 이러한 영상왜곡을 감소하기 위한 여러 방법 중 FOCUS-DWI가 있다. 본 논문은 선택적인 위상 방향 및 슬라이스를 이용하는 FOCUS-DWI가 자기장 내 중심축에서 거리변화에 따른 인공물, 균일도를 기존의 Conventional-DWI와 비교하여 그에 대한 유용성을 확인하고자 하였다. 인공물 발생에 대한 결과는 Conventional-DWI 기법에서 불규칙적인 줄무늬 인공물이 발생하였는데 중심축에서 인공물의 발생이 심하게 나타났고, 영상의 겹침 정도가 급격하게 증가하였다. 하지만 FOCUS-DWI 기법은 줄무늬 모양의 인공물 발생이 나타나지 않았고 영상의 겹침 정도도 적게 나타났으며, 영역별 신호측정에 대한 균일도 결과는 중심축에서 거리의 변화에 관계없이 FOCUS-DWI가 훨씬 우수한 기법으로 나타났다. 결론적으로 FOCUS-DWI 기법은 인공물, 영상의 겹침 정도, 균일도 측정에서 Conventional-DWI 기법보다 우수한 결과를 보였고, 거리의 변화에 따른 두 기법에서는 차이가 없게 나타났다. 따라서 FOCUS-DWI 기법은 영상의 왜곡 정도가 적고 화질이 우수하여 임상에서 활용도가 높을 것이라 사료된다.

남해 창선해역의 해수 및 진주담치의 위생학적 안전성 평가 (Microbiological Quality of the Shellfish-growing Waters and Mussels in Changseon, Namhae, Korea)

  • 유현덕;하광수;심길보;강진영;이태식;김지회
    • 한국수산과학회지
    • /
    • 제43권4호
    • /
    • pp.298-306
    • /
    • 2010
  • A sanitary survey was conducted to evaluate the water quality and mussel (Mytilus edulis) conditions of two administrative shellfish growing waters: those designated as shellfish growing water for export, and adjacent waters on the east coast of Changseon Island, Namhae, Korea. In all, 1,656 seawater and 166 mussel samples were collected at 46 stations for seawater and five stations for the shellfish from January 2007 to December 2009. Both seawater and mussels were examined for total coliforms and fecal coliforms. The standard plate count and most probable number of Escherichia coli were also determined for the shellfish samples. The range of the geometric means and the estimated 90th percentiles of fecal coliform for seawater samples at each station were <1.8-4.1 MPN/100 mL and <1.8-22.3 MPN/100 mL, respectively. The sanitary conditions for both shellfish growing areas, the designated shellfish growing area and adjacent area in Changseon, met the 'Approved area' criteria of the United States National Shellfish Sanitation Program. The range of E. coli detected in mussels in these areas was <20-500 MPN/100 g; and only 3 of 166 samples exceeded 230 MPN/100 g, the European standard for the consumption of raw bivalves. Therefore, the mussel farms in the Changseon area are classified as 'Class A' according to criteria set in European Community regulations. However, the levels of E. coli in mussels in parts of the designated shellfish growing area and adjacent area exceeded the bacterial limits after rainfall exceeding 45 mm. Further studies are needed to fully define the conditions leading to a temporary closure to harvest after a rainfall event.

분석용 네트워크구축을 위한 교통주제도 품질확보방안 (Transportation Digital Map Quality Guarantee Scheme for Analytic Network Building)

  • 최정민;주용진;최애심
    • Spatial Information Research
    • /
    • 제12권3호
    • /
    • pp.285-298
    • /
    • 2004
  • 교통주제도는 건설교통부와 교통개발연구원이 '국가교통DB구축사업'의 일환으로 제작한 것으로, 국토지리정보원이 항공사진을 기반으로 하여 작성한 NGIS(국가기본 수치지도)를 수정ㆍ보완하여 교통계획ㆍ투자분석 등 교통목적으로 재구축한 수치지도이다. 또한 교통부분 지리정보시스템(GIS-T)분야에서 교통정책 및 계획수립 등에 활용되고 있는 필수적인 기초 데이터이다. 이러한 교통주제도는 국가의 교통 정책결정과 연구분석에 활용되는 자료로 객관적이고 신뢰성 있는 데이터베이스이어야 한다. 또한 현실세계의 교통망을 모델링하여 반영한 것이므로 분석 기준년도에 대응되는 현재성과 정확성이 요구된다. 이를 위해 첫째, 조사 및 구축 지침을 통해 일관된 데이터의 생성 및 구축이 보장되어야하고 둘째, 데이터베이스를 구축함에 따라 발생할 수 있는 기하학적ㆍ논리적 오류를 파악하여야하며 셋째, 항목별 검수 방법과 절차에 대한 지침을 가지고 일관적이고 체계적인 점검을 하여야 한다. 본 연구에서는 교통주제도 데이터의 가장 기본이 되는 노드와 링크를 대상으로 항목별, 검수 절차와 방법에 대한 지침을 설정하고 일관적이고 체계적으로 데이터의 오류를 점검함으로써 교통 네트워크의 객관적이고 신뢰성 있는 품질확보가 가능하도록 하였다.

  • PDF

Bar 타겟을 이용한 DMC 영상의 공간해상력 검증 (Verification of Spatial Resolution in DMC Imagery using Bar Target)

  • 이태윤;이재원;윤부열
    • 한국측량학회지
    • /
    • 제30권5호
    • /
    • pp.485-492
    • /
    • 2012
  • 최근 디지털 항공영상 센서는 다양한 국가 공간정보기반구축에 큰 역할을 하고 있다. 하지만 고정밀의 신뢰성 있는 자료를 확보하기 위해서는 취득된 디지털영상에 대한 적절한 품질 평가 작업이 선행되어야 한다. 따라서 현재 관련분야의 연구가 국내외적으로 크게 주목을 받고 있다. 디지털카메라의 성능을 테스트하기 위한 영상해상력 검증용 테스트필드가 유럽과 미국 등에서 이미 설치 및 활용되고 있다. 이러한 테스트필드에는 카메라의 기하학적 성능분석을 위한 대공표지를 비롯하여 공간해상력 및 방사해상력 분석을 위한 다양한 형태의 타겟 역시 설치되어 있다. 본 연구에서는DMC 카메라의 공간해상력을 검증하기 위하여 영상에서 인식 가능한 크기의 바 타겟(bar target)을 제작 설치 후 항공촬영을 수행하였다. 연구에 사용된 DMC 영상의 이론적인 지상표본거리(GSD ; Ground Sample Distance)는 12cm 급으로, 촬영 비행방향과 비행방향의 직각방향에 대하여 보조영상과 집성영상에 대하여 각각 실제 해상력을 분석하였다. 연구결과 이론적인 해상력과 영상의 실제 해상력간의 차이는 약 0.6cm로 나타났으며, 블록의 가장자리에 위치한 영상에서 최대 1.5cm 정도로 나타났다.

선형적 위상배열 코일구조의 시뮬레이션을 통한 민감도지도의 공간 해상도 및 필터링 변화에 따른 MR-SENSE 영상재구성 평가 (Evaluation of MR-SENSE Reconstruction by Filtering Effect and Spatial Resolution of the Sensitivity Map for the Simulation-Based Linear Coil Array)

  • 이동훈;홍철표;한봉수;김형진;서재준;김소현;이춘형;이만우
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.245-250
    • /
    • 2011
  • Parallel imaging technique can provide several advantages for a multitude of MRI applications. Especially, in SENSE technique, sensitivity maps were always required in order to determine the reconstruction matrix, therefore, a number of difference approaches using sensitivity information from coils have been demonstrated to improve of image quality. Moreover, many filtering methods were proposed such as adaptive matched filter and nonlinear diffusion technique to optimize the suppression of background noise and to improve of image quality. In this study, we performed SENSE reconstruction using computer simulations to confirm the most suitable method for the feasibility of filtering effect and according to changing order of polynomial fit that were applied on variation of spatial resolution of sensitivity map. The image was obtained at 0.32T(Magfinder II, Genpia, Korea) MRI system using spin-echo pulse sequence(TR/TE = 500/20 ms, FOV = 300 mm, matrix = $128{\times}128$, thickness = 8 mm). For the simulation, obtained image was multiplied with four linear-array coil sensitivities which were formed of 2D-gaussian distribution and the image was complex white gaussian noise was added. Image processing was separated to apply two methods which were polynomial fitting and filtering according to spatial resolution of sensitivity map and each coil image was subsampled corresponding to reduction factor(r-factor) of 2 and 4. The results were compared to mean value of geomety factor(g-factor) and artifact power(AP) according to r-factor 2 and 4. Our results were represented while changing of spatial resolution of sensitivity map and r-factor, polynomial fit methods were represented the better results compared with general filtering methods. Although our result had limitation of computer simulation study instead of applying to experiment and coil geometric array such as linear, our method may be useful for determination of optimal sensitivity map in a linear coil array.

무등산국립공원의 생태적 질 평가 및 복원 가이드라인 수립 (Evaluation of Ecological quality and establishment of ecological restoration guideline in landscape level of Mt. Moodeung National Park)

  • 임치홍;박용수;안지홍;정성희;남경배;이창석
    • 생태와환경
    • /
    • 제49권4호
    • /
    • pp.296-307
    • /
    • 2016
  • 생태적 복원은 온전한 자연의 체계와 기능을 모방하여 인간이 훼손시킨 자연을 치유함으로써 다양한 생물들에게 서식공간을 제공하고 인류의 미래 환경을 확보하기 위한 생태기술이다. 이러한 생태적 복원은 복원대상에 대한 다각적 측면의 진단평가 결과에 근거하여 수립된 복원 가이드라인에 따라 수행되어야 한다. 본 연구에서는 무등산국립공원의 훼손된 산림의 생태적 질을 평가하고, 이를 회복시키기 위한 경관수준의 복원 가이드라인을 수립하였다. 이를 위해, 우선 자연적 요소(지형, 기후, 식생 분포)와 인위적 요소(토지이용, 선형 경관요소의 분포)를 고려하여 무등산국립공원에 성립해 있는 산림의 생태적 질을 진단하였다. 이와 더불어, 선형 경관요소에 의해 구획된 각 권역의 기하학적 속성 및 토지이용 강도에 근거하여 온전성 정도를 평가한 후 이를 점수화하였다. 분석 결과, 무등산국립공원의 거시적 지형은 모암의 풍화 특성에 의해 결정되는 양상이었으며, 식생대는 해발고도의 수직적 구배에 따라 난온대상록활엽수림대, 난온대낙엽활엽수림대 및 냉온대낙엽활엽수림대로 구분되었다. 토지이용유형에서 무등산국립공원은 활엽수림, 침엽수림 및 혼합림이 전체의 약 90%를 차지하였다. 경관파편화를 유발하는 경관요소로서 탐방로는 총 97개소로 파악되었다. 경관의 질 점수는 평균 $69.86{\pm}11.41$로 나타났다. 진단평가 결과, 무등산국립공원 내 산림의 생태적 질은 인간활동의 영향을 크게 받았고, 그 영향 정도는 지형에 따라 다르게 나타났다. 한편, 무등산국립공원은 산 중심으로 설정된 국립공원 경계와 모암의 풍화 특성에 의해 공원구역 내 수공간이 부족한 것으로 파악되어 이러한 문제를 해결하기 위해 주변 지역과의 생태네트웍 구축이 필요한 것으로 판단되었다. 본 연구에서는 이러한 진단평가 결과에 바탕을 두고 무등산국립공원의 생태적 질을 향상시키기 위한 복원 가이드라인을 제시하였다.

Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구 (A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash)

  • 양광길;정우영
    • 핵의학기술
    • /
    • 제13권3호
    • /
    • pp.56-60
    • /
    • 2009
  • 전신 뼈 영상 검사에서 영상의 질을 유지하면서 검사 시간 단축을 위해 oncoflash와 같은 프로그램을 사용하고 있는데, 이를 임상에 적용할 때 영상의 질과 검사 시간 단축의 두 가지 측면을 동시에 고려해야 하며, 적합한 스캔 속도의 결정에 대한 기준 설정이 필요하여 본 연구를 시행하였다. 서울아산병원 핵의학과에서 전신 뼈 영상 검사를 시행한 환자를 대상으로 하여 분당 30 cm의 스캔 속도로 검사한 영상의 총 계수를 각각 800 K 이하, 800 K, 900 K, 1000 K, 1500 K, 2000 K 이상으로 구분하여 영상의 질을 정성적 분석하고, 전신 총 계수가 1000 K 미만인 비율을 분석하였다. 분당 30 cm의 스캔 속도로 검사한 전신 뼈 영상의 전신 총 계수의 기하학적 평균이 1000 K 미만인 비율을 분석한 결과, 전체 329명 중 58명(17.6%)이다. 전신 총 계수 별로 구분한 영상을 정성적으로 분석 결과, 전신 총 계수 1000 K 이하의 경우에 육안적으로 영상의 입자가 거칠고, 노이즈가 증가한 영상으로 평가되었다. 전신 총 계수의 양과 Oncoflash 적용 여부에 따른 해상력의 비교평가를 위해 전신 뼈 영상 검사의 계수율을 고려하여 2~5 mCi의 선량을 투여한 $^{99m}Tc$ Flood와 4-Quadrant bar phantom을 이용하여 영상을 획득 한 후, Oncoflash 적용 전과 후의 FWHM을 분석하였다. PPM 계수가 3.6 K 이하에서는 Oncoflash 적용 후의 FWHM이 전과 비교해서 높게 나왔으나, 3.6~4.0 K 이상에서는 Oncoflash 적용 전보다 적용 후에 낮거나 동등하게 측정되었다. 전신 뼈 영상 검사의 시작 시점인 두부와 흉부의 일부가 포함된 상태에서 감마카메라의 PPM (Patient Positioning Monitor) 계수를 측정하고, 분당 30 cm의 스캔 속도를 적용하여 획득한 전신 총 계수 사이의 상관 관계를 분석 결과는 PPM 계수가 각각 2.5~3.0 K일 때 전신 총 계수의 평균과 표준 편차는 $965{\pm}173\;K$ (17.8%), 3.1~3.5 K에서 $1,084{\pm}154\;K$ (22.4%), 3.6~4.0 K에서 $1,242{\pm}186\;K$ (18.4%), 4.1~4.5 K에서 $1,359{\pm}170\;K$ (17.1%), 4.6~5.0 K에서 $1,405{\pm}184$ K (10.5%), 5.1~6.0에서 $1,640{\pm}376\;K$ (10.5%), 6.1~7.0 K에서 $1,771{\pm}324\;K$ (1.3%), 7.1 K 이상에서 $1,972{\pm}385\;K$ (2.0%)으로, 매우 강한 양의 상관관계(상관계수 r=0.775, p<0.01)가 있었다. 전신 뼈 영상 검사 시작 시점의 PPM 계수가 3.6 K 이상일 경우에 분당 30 cm으로 스캔한 후 전신 총 계수가 1000 K 이상인 경우에 Oncoflash를 적용하면 검사 시간을 줄이면서도 기존의 분당 15 cm으로 획득한 영상 수준의 화질을 얻을 수 있었다. 그러나 분당 30 cm으로 스캔한 후 전신 총 계수 기준으로 1000 K 미만인 경우에는 Oncoflash를 적용하여도 영상의 질이 저하되므로, 기존의 분당 15 cm의 속도로 다시 시행하는 것을 고려해야 할 것이다.

  • PDF