• 제목/요약/키워드: Generators

검색결과 1,899건 처리시간 0.031초

회전자 고정자권선의 절연보수후 절연특성변화 연구 (Change of the Insulation Characteristic for the Rotating machine stator winding after insulation reinforcement)

  • 오봉근;최교남;최형철;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.51-52
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

풍력 발전시스템을 위한 유도 발전기의 동특성해석 (Dynamic Analysis of Doubly Fed Induction Generators for Wind Power System)

  • 장석명;최장영;문정술;유대준;이정준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1753-1755
    • /
    • 2005
  • This paper deals with the dynamic analysis of doubly-fed induction generators for wind power system. The 3-phase voltage equations for stator and rotor of doubly-fed induction generator (DFIG) are derived and then, the equivalent circuit and mechanical output power of induction generators are obtained by converting the 3-phase voltage into do voltage equation. Finally, the dynamic characteristics such as torque, speed and voltage for rotor of DFIG are presented, for the case when wind is considered.

  • PDF

Characteristics of the Integrated Steam Generators for a Liquid Metal Reactor

  • Sim Yoon Sub;Kim Eui Kwang
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.127-141
    • /
    • 2004
  • Various types of integrated steam generators, which integrate IHTS and a steam generator into a single unit of equipment for an LMR, were analyzed using an analytic solution with some simplification. The analysis showed that the undesirable reversed heat transfer, of which occurrence was previously observed only in an integrated single-region bundle type, can also occur in an integrated double-region bundle type. The mechanism of the reversed heat transfer occurrence in the double-region type is explained and it is shown the mechanism in the double-region type is completely different from that in the single-region type. Based on this finding, a method for preventing the aforementioned heat transfer is suggested. The performance of the four types of the integrated steam generators is assessed. For this assessment, a SG is actually designed for each type and the optimization in the geometric parameters and flow rate are optimized.

건축물 내외부에 설치된 비상용 발전기 소음영향 평가 및 대책방안 사례연구 (A Case Study on Noise Impact Assessments and Countermeasures for Emergency Generators of the Data Center Building)

  • 윤대진;최재성;김창열;김한준
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.932-939
    • /
    • 2012
  • Recently, data centers are being established because IT and telecommunication industries are growing. The data centers have to install emergency generators to prevent unexpected shutdown of the electrical power supply. When the data centers are located in the densely populated urban area, the operating noise of the emergency generators can be a cause of people's complaints. In this case, it is necessary to establish effective countermeasure by noise & vibration specialists. To achieve this, noise reduction measure using noise measurement data and 3D noise analysis method have been employed in this study.

Sensitivity analysis of thermal-hydraulic parameters to study the corrosion intensity in nuclear power plant steam generators

  • Tashakor, S.;Afsari, A.;Hashemi-Tilehnoee, M.
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.394-401
    • /
    • 2019
  • The failure of steam generators (SGs) due to corrosion is one of the most important problems in power plants. Impurities usually accumulate in the hot sides of SG and form deposits on the SG surfaces. In this paper, the sensitivity analysis of the accumulation of water impurities in the heat exchangers of nuclear power plants is presented. The convection-diffusion equation of the liquid phase on the heated surfaces is derived and then solved by the finite volume method. Also, the effects of the thermal-hydraulic parameters in the form of dimensionless numbers, such as $Pe_q$, $Pe_u$, $k_q$(relative solubility of impurity between the steam and water) on the impurities concentration are studied.

자기-기계-전기 변환소자를 이용한 에너지 하베스팅 기술 (Recent Progress in Magneto-Mechano-Electric Generators)

  • 황건태;류정호;윤운하
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.271-282
    • /
    • 2021
  • The internet of things (IoT) technology is a key component for the advent of 4th industrial revolution, which is the network of home appliances, infrastructures, and vehicles to remotely investigate these systems. For the operation of compact IoT devices, batteries are widely used as electric power, and the limited lifetime of batteries inevitably leads to periodic replacement. Magneto-mechano-electric (MME) generators may be alternatives to batteries inside the IoT devices by converting stray magnetic field into electric energy, since we are always surrounded by ambient alternating current (AC) magnetic fields induced from electric power transmission lines everywhere. This article reviews the recent domestic research progress in high-performance MME generators and their application field for IoT and electronic devices.

On Generators in the Category of Actions of Pomonoids on Posets and its Slices

  • Farideh, Farsad;Ali, Madanshekaf
    • Kyungpook Mathematical Journal
    • /
    • 제62권4호
    • /
    • pp.657-671
    • /
    • 2022
  • Where S is a pomonoid, let Pos-S be the category of S-posets and S-poset maps. We start off by characterizing the pomonoids S for which all projectives in this category are either generators or free. We then study the notions of regular injectivity and weakly regularly d-injectivity in this category. This leads to homological classification results for pomonoids. Among other things, we get find relationships between regular injectivity in the slice category Pos-S/BS, for any S-poset BS, and generators and cyclic projectives in Pos-S.

Starter/Alternator Systems for HEV and Their Control: A Review

  • Boldea, Ion.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권4호
    • /
    • pp.157-169
    • /
    • 2004
  • Motor & generator operation at widely variable speeds is needed in various applications but hybrid and electric vehicle (HEV) stand out today, as quite a few companies are launching this year their mass production of HEVs. The quest for better starter-generators is far from ended, though. The present review paper unfolds a comparative critical evaluation of various starter-generators and their control for HEV. Induction, interior PM synchronous, transverse-flux PM synchronous, switched reluctance, together with claw-pole and biaxial excitation PM synchronous (BEGA) configurations with their control are all considered in system evaluations.

주파수 안정도 유지를 위한 부하차단 시뮬레이션-가스분리플랜트 사례 (LOAD SHEDDING SIMULATION FOR MAINTAINING FREQUENCY STABILITY-GAS SEPARATION PLANT CASE)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.72_73
    • /
    • 2009
  • The industrial power system has the radial plant distribution system and domestic generators to supply the essential loads. When the system is isolated from the utility tie line, the system frequency drops resulting in the trip of generators. The load shedding scheme shall be properly designed to secure the essential load. In this paper two kinds of load shedding schemes, those are, the Fast Act Load Shedding(FALS) and Under Frequency Load Shedding(UFLS) are simulated and compared taking an example of petrochemical gas separation plant.

  • PDF

A NEW VERSION OF FIRST RETURN TIME TEST OF PSEUDORANDOMNESS

  • Kim, Dong-Han
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제12권2호
    • /
    • pp.109-118
    • /
    • 2008
  • We present a new version of the first return time test for pseudorandomness. Let $R_n$ be the first return time of initial n-block with overlapping. An algorithm to calculate the probability distribution of the first return time $R_n$ for each starting block is presented and used to test pseudorandom number generators. The standard Z-test for log $R_n$ is applied to test the pseudorandom number generators.

  • PDF