• Title/Summary/Keyword: Generators

Search Result 1,899, Processing Time 0.022 seconds

Determination of Critical Generator Group Using Accelerating Power and Synchronizing Power Coefficient in the Transient Energy Function Method

  • Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.161-166
    • /
    • 2011
  • This paper proposes an algorithm for determining critical generator lists using accelerating power and synchronizing power coefficient (SPC), and critical generator group (CGG) from CGG candidates, which is a combination of critical generators. The accurate determination of CGG provides a more accurate energy margin while providing system operator with information of possible unstable generator group. Classical transient energy function (TEF) method selects the critical generators with big corrected kinetic energy of each generator at the moment of fault removal. However, the generator with small acceleration after fault, that is, the generator with small corrected kinetic energy, is also likely to belong to CGG if the generator has small synchronizing power. The proposed algorithm has been verified to be effective compared with the classical TEF method. We utilized the power system of Korean Electric Power Corporation(KEPCO) as a test system.

Feasibility Study on the Integration Power System combining Tidal Power Generation and Ocean Current Power Generation (조력발전과 해류발전을 겸하는 통합발전시스템 타당성 연구)

  • Jang, Kyung-Soo;Lee, Jung-Eun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.611-614
    • /
    • 2009
  • The present paper relates to an integration power system combining tidal power generation and ocean current power generation, and more particularly, to an integration power system combining a tidal power plant and two ocean current power parks, which is capable of increasing the operating rate of power facilities and efficiently generating electrical energy by using incoming seawater into the lake through turbine generators of a tidal power plant or fast flow of seawater discharged to a sea side through sluice gates of a tidal power dam. It is shown that the integration power system is a new promising ocean power system and the ocean current turbine generators in the ocean current power parks of the integration power system are smaller in size and larger in power generation capacity compared with the tidal current turbine generators in the ocean.

  • PDF

A Study on the Analysis of Failures Related to Emergency Diesel Generators in Overseas Nuclear Power Plants (원전용 비상디젤발전기 국외 손상사례 분석에 관한 연구)

  • Chang, Jung-Hwan;Kim, Jin-Sung;Chung, Hae-Dong;Cho, Kwon-Hae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • The emergency diesel generator (EDG) in a nuclear power plant (NPP) shall start within 10 secondss and supply electrical power to engineered safety features within one minute and less if a loss of offsite power (LOOP), A design-basis event, or their combination occur. Each NPP has an EDG set consisting of two diesel generators for redundancy. In addition to the EDG set, an alternate Alternating Current Diesel Generator (AAC DG) is installed and shared by several units to cope with a station black out (SBO), i.e., loss of the offsite power concurrent with reactor trip and unavailability of the EDG set. The objective of this study is to analyze the failure data of emergency diesel generators reported in overseas nuclear power plants.

  • PDF

Shape Optimization for the EMF Harmonics Reduction of PM Type Synchronous Generators (영구자석 계자형 동기발전기의 고주파 저감을 위한 자기회로 최적설계)

  • Kim, Yeong-Gyun;Lee, Jae-Geon;Im, Yang-Su;Gang, Gyu-Hong;Hong, Jeong-Pyo;Jang, Gi-Chan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.10
    • /
    • pp.494-500
    • /
    • 2001
  • This paper presents the shape optimization to minimize the BEMF(Back Electro-Motive Force) harmonics of PM type synchronous generators. RSM(Response Surface Methodology) is well adapted to make analytical model for a complex problem considering a lot of interaction of design variables. In this paper, RSM is used to find the optimal solution. The 2D-Finite Element Method is used to obtain the observer data of the BEMF and SQP(Sequential Quadratic Problem method) is used to solve the constrained nonlinear optimization problem.

  • PDF

A Study of In-Depth Diagnosis Method for Automatic Synchronizing Circuits (자동동기검출회로 성능진단에 관한 연구)

  • Park, Ho-Cheul;Chun, Yung-Sik;Jang, Ki-Jun;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.582-584
    • /
    • 1999
  • Generator has synchronized with power Network after build-up output voltage. In order to prevent a current surge when synchronizing, the conditions such as identical no-load voltages identical no-load frequencies and identical phase positions must be met between generator voltage and network voltage. Hydro-Pump generators or Gas-turbine generators, Co-generation Generators that serve peak load of network are synchronized many times. So, Automatic Synchronizing Circuits are very important service. This report apply Diagnosis methods the Automatic Synchronizing Circuits(Device) by developing simulator.

  • PDF

Analysis of Insulation Characteristics for Stator Winding after Insulation Reinforcement (수력발전기 고정자권선의 절연보강 후 절연특성 분석)

  • Oh, Bong-Keun;Choi, Kyo-Nam;Choi, Hyung-Cheol;Lim, Kee-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.71-73
    • /
    • 2006
  • Our company(KOWACO) has periodically performed off-line diagnostic test for 14 hydro generators (rated 11 kV over) for 15 years. In this paper, we summarized results of dissipation factor tip-up test and partial discharge test about these generators. Among these, we chose two generators and performed insulation reinforcement (cleaning and varnish Painting). We compared change of insulation condition for the stator winding based upon off-line diagnostic test result before and after repair. Test result shows that insulation condition was improved after insulation reinforcement. This insulation reinforcement has a function to reduce cause of deterioration, so we can know that it extends lifetime of generator and it is a very important factor for stable operation of facilities.

  • PDF

Stochastic precipitation modeling based on Korean historical data

  • Kim, Yongku;Kim, Hyeonjeong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.23 no.6
    • /
    • pp.1309-1317
    • /
    • 2012
  • Stochastic weather generators are commonly used to simulate time series of daily weather, especially precipitation amount. Recently, a generalized linear model (GLM) has been proposed as a convenient approach to fitting these weather generators. In this paper, a stochastic weather generator is considered to model the time series of daily precipitation at Seoul in South Korea. As a covariate, global temperature is introduced to relate long-term temporal scale predictor to short-term temporal predictands. One of the limitations of stochastic weather generators is a marked tendency to underestimate the observed interannual variance of monthly, seasonal, or annual total precipitation. To reduce this phenomenon, we incorporate time series of seasonal total precipitation in the GLM weather generator as covariates. It is veri ed that the addition of these covariates does not distort the performance of the weather generator in other respects.

Identification of coherent generators for dynamic equivalents using artificial neural network (신경망을 이용한 코히런트발전기의 선정)

  • Rim, Seong-Jeong;Han, Seong-Ho;Yoon, Yong-Han;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.3-5
    • /
    • 1993
  • This paper presents a identification techniques of coherent generators for dynamic equivalents using artificial neural networks. In the developed neural network, inputs are the power system parameters which have a property of coherency. Outputs of the neural network are coherency and error indices which are derived from density measure concept. The learning of developed neural network is carried out by means of error back-propagation algorithm. Identification of coherent generators are implemented by proposed grouping algorithm using coherency and error indices. The proposed method is confirmed by simulations for 39-bus New England system.

  • PDF

Optimum Design of Six-Bar Function Generators with Prescribed Functions Defined for the Entire Motion Range (전체 운동가능구간에 걸쳐 함수가 정의된 6절 함수발생장치의 최적설계)

  • Lee, Sang-Choon;Shin, Jae-Gyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2527-2534
    • /
    • 2002
  • An efficient method is proposed for the design of six-bar function generators with complex design tasks. Especially, the desired functions are defined for the entire motion ranges of the input variables. The design problem is defined as a nonlinear optimization problem. A concept of a weighted structural error is introduced for the definition of the objective function. Also simple branch identifiers are incorporated to eliminate the branch problems commonly encountered in a typical linkage synthesis problem. Two example problems of designing a Watt-II type double dwell mechanism and a Stephenson-III type double beat-up mechanism are demonstrated with numerical results. Constraints such as on the Grashof conditions and on the transmission angles are included for practical solutions.

Numerical Simulation on Interactions of Longitudinal Vortices in a Turbulent Boundary Layer (종방향 와동과 난류경계층의 상호작용에 관한 수치해석)

  • Yang Jang-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.637-644
    • /
    • 2005
  • This paper describes the numerical simulation of the interaction between longitudinal vortices ("common flow up") and a 3-D turbulent boundary layer over a flat plate To analyze the common flow up Produced from vortex generators. the flow field behind the vortex generators Is modeled by the information that is available from studies on a half-delta winglet. Also. the Reynolds-averaged Navier-Stokes equation for three-dimensional turbulent flows. together with a two-layer turbulence model to resolve the near-wall flow, is solved by the method of AF-ADI. The computational results predict that the boundary layer is thinned in the regions where the secondary flow is directed toward the wall and thickened where it is directed away from the wall Also. the numerical results. such as Reynolds stresses. turbulent kinetic energy and skin friction characteristics generated from the vortex generators . are reasonably close to the experimental data.