• Title/Summary/Keyword: Generation2

Search Result 12,483, Processing Time 0.035 seconds

Suicidal Ideation in Korean Echo Generation and Associated Factors : Using 2012 Korea Health Panel Data (우리나라 에코세대의 자살생각과 관련요인: 2012년도 한국의료패널 자료를 이용하여)

  • Park, Min Jeong
    • Journal of Home Health Care Nursing
    • /
    • v.23 no.1
    • /
    • pp.34-44
    • /
    • 2016
  • Purpose: This study investigated the factors associated with suicidal ideation in the Korean Echo Generation using 2012 Korea Health Panel Data. Methods: The 2012 Korea Health Panel Data were collected from February 2012 to July 2012 and included 2,303 people who responded to a question asking whether they had experienced suicidal ideation. The data were analyzed by chi-square and multiple logistic regression test using SPSS 22.0. Results: The rate of suicidal ideation was 4.2% in the Echo Generation. Factors associated with suicidal ideation in the Echo Generation revealed that the following variables increased the rate of suicidal ideation: sex(odd ratio: 2.39, CI: 1.39-4.09), education(odd ratio: 1.95, CI: 1.08-3.52), depression(odd ratio: 12.06, CI: 6.92-21.03), frustrating experience(odd ratio: 2.52, CI: 1.22-5.20), anxiety about the future(odd ratio: 14.58, CI: 3.20-66.41), self-rated health status(odd ratio: 2.39, CI: 1.39-4.09 and odd ratio: 6.41, CI 2.87-14.33). Conclusion: This study provides a preliminary examination of the factors associated with suicidal ideation in the Echo Generation. A more careful examination may be warranted.

Periodically Poled BaTiO3: An Excellent Crystal for Terahertz Wave Generation by Cascaded Difference-frequency Generation

  • Li, Zhongyang;Yuan, Bin;Wang, Silei;Wang, Mengtao;Bing, Pibin
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.179-184
    • /
    • 2018
  • Terahertz (THz) wave generation by periodically poled $BaTiO_3$ (PPBT) with a quasi-phase-matching (QPM) scheme based on cascaded difference-frequency generation (DFG) is theoretically analyzed. The cascaded DFG processes comprise cascaded Stokes and anti-Stokes processes. The calculated results indicate that the cascaded Stokes processes are stronger than the cascaded anti-Stokes processes. Compared to a noncascaded Stokes process, THz intensities from $20^{th}$-order cascaded Stokes processes increase by a factor of 30. THz waves with a maximum intensity of $0.37MW/mm^2$ can be generated by $20^{th}$-order cascaded DFG processes when the optical intensity is $10MW/mm^2$, corresponding to a quantum conversion efficiency of 1033%. The high quantum conversion efficiency of 1033% exceeds the Manley-Rowe limit, which indicates that PPBT is an excellent crystal for THz wave generation via cascaded DFG.

Hydrogen Generation through the Reaction with Water of MgO, MgCl2 or Ni+Nb2O5 - Added Magnesium Hydrides

  • Hong, Seong-Hyeon;Kim, Hyun-Jin;Song, Myoung Youp
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • Hydrogen was generated by the reaction of metal hydride with water. The variation of hydrogen generation with the kind of powders (milled $MgH_2$, and $MgH_2$ milled with various contents of MgO, $MgCl_2$ or $Ni+Nb_2O_5$) was investigated. $MgH_2$ powder with a hydrogen content of 6.05 wt% from Aldrich Company was used. Hydrogen is generated by the reaction of Mg as well as $MgH_2$ with water, resulting in the formation of byproduct $Mg(OH)_2$. For about 5 min of reaction time, milled $95%MgH_2+5%MgO$ has the highest hydrogen generation rate among milled $MgH_2+x%MgO$ (x=0, 5, 10, 15 and 20) samples. Milled $90%MgH_2+10%MgCl_2$ has the highest hydrogen generation rate among all the samples.

A Development of GPS SIS Anomalies Generation Software

  • Han, Younghoon;Ko, Jaeyoung;Shin, Mi Young;Cho, Deuk Jae
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.2 no.1
    • /
    • pp.33-40
    • /
    • 2013
  • In this paper, GPS signal anomaly generation software is proposed which can be used for the analysis of GPS signal anomaly effect and the design, verification, and operation test of anomalous signal monitoring technique. For the implementation of anomalous signal generation technique, anomalous signals are generated using a commercial signal generation simulator, and their effects and characteristics are analyzed. An error model equation is proposed from the result of analysis, and the anomalous signal generation software is constructed based on this equation. The proposed anomalous signal generation software has high scalability so that users can easily utilize and apply, and is economical as the additional cost for purchasing equipment is not necessary. Also, it is capable of anomalous signal generation based on real-time signal by comparing with the commercial signal generation simulator.

Examination of excess electricity generation patterns in South Korea under the renewable initiative for 2030

  • Kim, Philseo;Cho, So-Bin;Yim, Man-Sung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2883-2897
    • /
    • 2022
  • According to the Renewable Energy 3020 Implementation Plan announced in 2017 by the South Korean government, the electricity share of renewable energy will be expanded to 20% of the total electricity generation by 2030. Given the intermittency of electricity generation from renewable energy, realization of such a plan presents challenges to managing South Korea's isolated national electric grid and implies potentially large excess electricity generation in certain situations. The purpose of this study is: 1) to develop a model to accurately simulate the effects of excess electricity generation from renewables which would arise during the transition, and 2) to propose strategies to manage excess electricity generation through effective utilization of domestic electricity generating capabilities. Our results show that in periods of greater PV and wind power, namely the spring and fall seasons, the frequency of excess electricity generation increases, while electricity demand decreases. This being the case, flexible operation of coal and nuclear power plants along with LNG and pumped-storage hydroelectricity can be used to counterbalance the excess electricity generation from renewables. In addition, nuclear energy plays an important role in reducing CO2 emissions and electricity costs unlike the fossil fuel-based generation sources outlined in the 8th Basic Plan.

Factors Influencing Post-Adoption Resistance to Self-Order Kiosks at Fast-Food Restaurants: A Focus on the New-Silver Generation

  • Hwaran Lee;Eunkyung Kang;Kyung Young Lee;Minwoo Lee;Sung-Byung Yang
    • Journal of Smart Tourism
    • /
    • v.3 no.2
    • /
    • pp.23-36
    • /
    • 2023
  • Due to the phenomenon of aging, a new consumer segment known as the "new-silver generation" is emerging. Unlike the previous silver generation, this generation possesses significant economic power and consuming willingness, attracting attention from consumer goods companies. However, both the new-silver generation and the elderly face challenges in adopting contactless or self-service technologies such as self-order kiosks, resulting in negative reactions. Therefore, this study aims to investigate the attitude and response of the newsilver generation towards kiosks, as well as the factors influencing their resistance to such technology. By applying theoretical perspectives from the innovation resistance model, technostress theory, and the value-based model, this study identifies influencing factors for innovation resistance among the new-silver generation when using contactless technologies implemented in fast-food restaurants. The findings indicate that a lower awareness of new technologies and services corresponds to decreased adoption resistance, while a higher perceived value leads to more positive behaviors and attitudes among the new-silver generation utilizing kiosks at fast-food restaurants.

Environmental Impact Evaluation for the Power Generation System Using the LCA Methodology (LCA 기법을 이용한 발전시스템의 환경성 평가)

  • Ko, Kwang-Hoon;Hwang, Yong-Woo;Park, Kwang-Ho;Jo, Hyun-Jung;Jae, Moo-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.704-711
    • /
    • 2005
  • In this study, life cycle assessment(LCA) for the nuclear power generation system and the thermal power generation system, which make a great distribution of the electric power supply in Korea, has been carried out to compare the environmental impact between two power generation systems. In system boundary of this study, the stage of construction, operation and demolition & disposal were included. For life cycle impact assessment(LCIA), three cases were considered; the single environmental impact for the $CO_2$ emissions, the 8 major global environmental impact, and the major global environmental impact categories including radioactive impact. As the results, it was found that the nuclear power generation system is environmentally superior to the thermal power generation system as 10,000 times in the evaluation for the $CO_2$ emissions, 90 times in the evaluation for the 8 major environmental impact categories, and 40 times in the evaluation for the environmental impact categories including radioactive impact.

Power Pattern Analysis According to Irradiation for Photovoltaic Systems (태양광 발전시스템의 일사량에 따른 전력 패턴 분석)

  • Park, Sang-Jun;Kim, Hyeong-Seok;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.46-48
    • /
    • 2009
  • This paper aims to investigate generation conditions necessary for the most efficient generation by measuring electricity power under various irradiation conditions, since the photovoltaic generation system has high costs and low efficiency. In addition, because the irradiation varies hourly, daily, monthly, and yearly, the research on the irradiation necessary for photovoltaic generation was carried out by analyzing the pattern o( Bower under various irradiation conditions. Also, after measuring the daily variations of irradiation and generation power, the monthly accumulated irradiation and monthly accumulate power which had the most generation power were investigated and the pattern of the annual generation power was analyzed. The results of this study are as follows. As for the relationship between the photovoltaic generation system and the irradiation, the generation power increased with the irradiation and when the irradiation was more than 600 $[W/m^2]$ the generation power amounted to more than 100 [Wh] as the resonable result.

  • PDF

A Study on Development of Wind Power 400W Generation System with Vertical axis Type (400W 수직형 풍력발전시스템의 개발에 관한 연구)

  • Yoon, Jeong-Phil;Choi, Jang-Kyun;Cha, In-Su
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.23-30
    • /
    • 2006
  • Need developments of substitute energy to solve problem of global warming by excess use of fossil energy, excess discharge of carbon dioxide. wind power generation system is all-important energy in next generation as clean energy. Environmental pollution of wind power generation system is not exhausted entirely. And, electric-power generation system cost is cheap than other energy. Wind Generation system that is supplied much present is most horizontality style blade structure. But, Horizontal style structure is serious noise and there is problem in stability of blade. We designed special blade solve to this problem. And, manufactured vertical axis wind power generation system because using blade. Also, developed assistance power generator to increase driving efficiency ago wind power generation. We expect this devices that is such cover shortcoming of wind power generation system.

  • PDF

Study on the Generation of Chemically Active Species using Air-plasma Discharging System (공기-플라즈마 방전 시스템에서 화학적 활성종의 생성에 대한 연구)

  • Kim, DongSeog;Park, YoungSeek
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.401-408
    • /
    • 2012
  • High-voltage dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. The initiation and propagation of the electrical discharges depends on several physical, chemical, and electrical parameters such as 1st and 2nd voltage of power, gas supply, conductivity and pH. These parameters also influence the physical and chemical characteristics of the discharges, including the production of reactive species such as OH, $H_2O_2$ and $O_3$. The experimental results showed that the optimum 1st voltage and air flow rate for RNO (N-Dimethyl-4-nitrosoaniline, indicator of the generation of OH radical) degradation were 160 V (2nd voltage of is 15 kV) and 4 L/min, respectively. As the increased of the 2nd voltage (4 kV to 15 kV), RNO degradation, $H_2O_2$ and $O_3$ generation were increased. The conductivity of the solution was not influencing the RNO degradation and $H_2O_2$ and $O_3$ generation. The effects pH was not high on RNO degradation. However, the lower pH and the conductivity, the higher $H_2O_2$ and $O_3$ generation were observed.