• Title/Summary/Keyword: Generated PWM

Search Result 158, Processing Time 0.029 seconds

Leakage Current Reduction by a New Combination of PWM Method and Modified connection for 3-level Inverter Photovoltaic PCS (3상 3레벨 태양광 PCS에서 누설전류 저감 기법)

  • Seng, Chhaya;Jo, Jongmin;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.346-347
    • /
    • 2020
  • This paper presents the two combination methods for leakage current reduction in photovoltaic system PCS. The leakage current in the photovoltaic system generated from the parasitic capacitance existing between the photovoltaic system and ground relevance to common mode voltage caused by PWM switching. Firstly, Leakage current reduced by a PWM method using two carriers with 180-degree phase different. Secondly, the leakage current is more reduced by connecting LCL filter to the mid-point of DC link. This combining method is revealed in PSIM simulation with 1 uF parasitic capacitance.

  • PDF

A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor (PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제-)

  • 성병모;류도형;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.443-450
    • /
    • 2000
  • A PWM inverter for an induction motor often has a problem with a high frequency leakage current that flows through stray capacitors between stator windings and a motor frame to ground. This paper proposes a new type of Active Common Mode Voltage Canceler circuit for the reduction of common mode voltage and high frequency leakage current generated by the PWM VSI-fed induction motor drives. The compensating voltage applied by the common made voltage canceler has the same amplitude as, hut the opposite polarity to, the common mode voltage by PWM Inverter. Therefore, common mode voltage and high frequency leakage current can be canceled. The proposed circuit consists of four-level half-bridge inverter and common-mode transformer. Simulated and experimental results show that common mode voltage canceler makes significant contributions to reducing a high frequency leakage current.

  • PDF

Design of PWM-Based Photo Irradiation System for Acne Treatment (여드름 치료를 위한 PWM 기반 광 조사 시스템 설계)

  • Kim, Chang-Su;Lim, Hyun-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.3
    • /
    • pp.207-215
    • /
    • 2012
  • As one of photo dynamic therapies, the existing LED photo irradiation method with 635 nm continuous wave has most frequently been used for acne treatment, it suffered from a low energy efficiency and generation of a large amount of heat in tissues requiring improvement measures. In this thesis, a LED photo irradiation system for acne treatment has been designed using PWM(Pulse Width Modulation) mode to enhance the energy efficiency and prevent thermal destruction in tissues. System configuration consisting largely of timer module, PWM module, and photo transfer device has been designed with the use of 1 W LED at a wavelength of 660 nm for the photo transfer device to increase skin penetration depth for treatment of acne. Frequency and wave form generated by using PWM control was verified along with confirmation of output energy of 660 nm LED and surface temperatures of tissues, followed by evaluation of stable energy outputs and stability of tissues. The results indicated that whereas power loss was high and thermal destruction in tissues was exhibited when C.W mode was used to obtain the optical energy of 1 W LED at a wavelength of 660 nm for acne treatment, realization of PWM mode allowed lowering of power consumption for LED through pulse width modulation, and no occurrence of thermal destruction in tissues, suggesting that PWM mode is safer and more effective for treatment of acne than C.W mode.

Current-Programmed Control of Three Phase PWM AC-AC Buck Converter

  • Choi, Nam-Sup;Li, Yulong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.356-361
    • /
    • 2005
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. Compared to duty-ratio voltage control, current programmed control has several advantages such as reduction of system order and inherent current protection. By considering only the magnitude components, the same scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. Sensing the output voltage and the inductor current, an error signal will be generated by comparing the output voltage magnitude with a reference value. Then the error signal will be processed by a PI compensator to generate the current command. The converter switches will the change the state by a periodic clock pulse or at the instants when the inductor current magnitude reaches the current command. As an example case, the buck converter is treated. The converter analysis is carried out by applying the complex DQ circuit transformation to obtain basic physical insight into the converter operation and to establish some important characteristic equations for control purpose. The simulation with Simplorer shows the validity of the proposed scheme and the experimental results support the verification of the design.

  • PDF

A Study on Synchronized AC Power Source Voltage Regulator of Voltage Fed Inverter using a Photovoltatic effect (PV효과를 이용한 전압형 인버어터 전원동기 전압 조정기에 관한 연구)

  • Hwang, Lak-Hoon
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.120-129
    • /
    • 1998
  • In this paper represented uninterruptible power sypply(UPS) equipment maintaining constant output voltage, using a pulse width modulation(PWM) voltage fed inverter, as power source disconnection, voltage variation and output current variation with load variation. This system is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a Photovoltaic (PV) that it was so called constant voltage charge. In addition, better output waveform was generated because of PWM(pulse width Modulation) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

  • PDF

Optimal Switching Pattern of Voltage Source Inverter (전압원인버어터의 최적스위칭패턴)

  • 정필선;정동화;이윤종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.4
    • /
    • pp.386-398
    • /
    • 1987
  • This paper is proposed the Suboptimal PAWM(Pulse Amplitude Width Modulation) for minimize harmonic effects generated by switching operation of PWM Inverter. This strategy determine one switching pattern at a fixed point(fundamental) voltage u1=1.2) which THD(Total Harmonic Distortion) are minimized in the suboptimal PWM strategy, and controls only frequency in the inverter while voltage control is carried out by DC Chopper in the DC Link. This strategy is applied at VSD(Variable Speed Drive) of Three phase induction moter, and acoustic noise of motor, line to line voltage and current of inverter, current harmonic spectrum was estimated and also compared with other switching strategy. From the results, the validity of this strategy can be verified.

  • PDF

Design of LCL-filter for Grid-Connected Three-Phase Inverters Using a Discontinuous PWM Method (DPWM 방식을 적용한 3상 계통 연계 인버터의 LCL-필터 설계)

  • Lee, Jung-Rok;Seo, Seung Gyu;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.419-427
    • /
    • 2016
  • This paper proposes a design method of LCL-filter for a grid-connected three-phase inverter using a discontinuous PWM (DPWM) method. When using a DPWM method, many harmonic voltages are generated in the inverter output compared to a continuous PWM (CPWM) method. Therefore, an optimized grid-connected filter design is required for a DPWM method. The proposed design method provides generalized formula to design accurate LCL-filter without trial and error procedures. An inverter side inductance is designed by analyzing the current ripple injected to the grid. The Optimized parameters of LCL-filter can be designed by analyzing the total harmonic distortion (THD) and the ripple attenuation factor of the output current. The proposed LCL filter design method is demonstrated by simulation and experimental results.

A Dual-Output Integrated LLC Resonant Controller and LED Driver IC with PLL-Based Automatic Duty Control

  • Kim, HongJin;Kim, SoYoung;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.886-894
    • /
    • 2012
  • This paper presents a secondary-side, dual-mode feedback LLC resonant controller IC with dynamic PWM dimming for LED backlight units. In order to reduce the cost, master and slave outputs can be generated simultaneously with a single LLC resonant core based on dual-mode feedback topologies. Pulse Frequency Modulation (PFM) and Pulse Width Modulation (PWM) schemes are used for the master stage and slave stage, respectively. In order to guarantee the correct dual feedback operation, Phased-Locked Loop (PLL)-based automatic duty control circuit is proposed in this paper. The chip is fabricated using $0.35{\mu}m$ Bipolar-CMOS-DMOS (BCD) technology, and the die size is $2.5mm{\times}2.5mm$. The frequency of the gate driver (GDA/GDB) in the clock generator ranges from 50 to 425 kHz. The current consumption of the LLC resonant controller IC is 40 mA for a 100 kHz operation frequency using a 15 V supply. The duty ratio of the slave stage can be controlled from 40% to 60% independent of the frequency of the master stage.

Design and Implementation of an Active Power Filter Using Model Predictive Controller

  • Haeri, Mohammad;Zeinali, Mahdi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1975-1980
    • /
    • 2004
  • A parallel active power filter is designed and implemented to compensate for undesired current harmonics generated by a nonlinear load. The filter works based on PWM strategy and control signal is generated using a model predictive controller. To evaluate the achievements, a PI controller is also designed and implemented. Experimental results indicate about 50% increase in the efficiency over PI controller.

  • PDF

LED Board Optimization Design for User-Friendly System Configuration (사용자 친화적 시스템 구성을 위한 LED 보드 최적화 설계)

  • Ju-An Park;Chang-Woo Han;Hui-Sang Yoo;Boong-Joo Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.859-866
    • /
    • 2023
  • This paper focuses on configuring a user-friendly system of LED systems by applying improvement measures such as gamma correction, non-flicker, and driving noise removal using MCUs and LED drivers. As a result of the experiment, the 22kHz PWM mode of the LED driver generated noise outside the audible frequency range, making it practically imperceptible to users. The appropriate pull-up resistor values within the normal operating delay ratio of 5% were found to be 1kΩ to 10kΩ for the 3kHz PWM mode and 1kΩ to 2kΩ for the 22kHz PWM mode. In addition, gamma correction can be optimized for nonlinear human visual systems to express accurate contrast and as a result, it is expected to develop an LED system that can be expressed more naturally and accurately than conventional LED systems and improve users' visual experience.