• 제목/요약/키워드: General water

검색결과 3,179건 처리시간 0.03초

실내조경 수공간의 이용만족도 요인 평가 (A Study on User's Satisfaction of Water Space Design in Interior Landscape Architecture Space)

  • 진금해;최만봉;노재현
    • 한국조경학회지
    • /
    • 제31권1호
    • /
    • pp.23-33
    • /
    • 2003
  • The purpose of this study is to analyse six different factors of water space that influence interior landscape architecture of officers and commercial spaces. Six different factors of water space that influence interior landscape architecture are the height of the water space, the design form, the blending with the location environment, location, general satisfaction with the water space, and general satisfaction with whole space. The results of this study are as follows: 1. Water space of commercial space was bigger than office space. The satisfaction is the highest in 0∼0.6M(B2) of office space and 3.5M(C6) of commercial space. The cascade form in the office space and large water volume design in commercial areas, which supplies abundant sound and water volume, were the highest. 2. In the analysis of preferences, the design form and the general design of the office space influences satisfaction levels. The height of the water space, and a combination of other factors influence general satisfaction. Water space influences commercial areas in higher degrees. 3. The items were most desired or satisfactory for interior landscape architecture were a cascade, water fall, and small water fountain. 4. A place introduced with water space had higher satisfaction levels. Water space produces higher than general satisfaction and indicates water, space alone cannot make general interior space satisfactory, although it can make interior landscape architecture space satisfactory. 5. There is more general satisfaction in commercial space than in office space. 6. The design of water space influences overall satisfaction: a rest area of office space needs an impressive and aggressive approach, while the office space should harmonize with its surroundings, as a commercial space.

A new method for measuring ultra-low water vapor permeation for OLED displays

  • Dunkel, Ralf;Bujas, Roko;Klein, Andre;Horndt, Volker;Wrosch, Matt
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.589-593
    • /
    • 2005
  • It is well known that proper encapsulation is crucial for the lifetime of organic light emitting diode (OLED) displays. With the development of increasingly better barrier coatings and perimeter seals, it has now become very desirable to be able to precisely measure the rate of water vapor and oxygen permeation through barrier coatings and perimeter sealing. This paper demonstrates a new permeation measurement method that uses tritium-containing water (HTO) as a tracer material. The theoretical detection limit of this direct method is $2.4{\times}10^{-8}g/(m^2day)$.

  • PDF

UV/TiO2 수처리 공정에서의 살균에 관한 연구 (A Study on the matter of Disinfection in UV/TiO2 Water Treatment process)

  • 이규환;이상진;이용재;이동석
    • 산업기술연구
    • /
    • 제27권A호
    • /
    • pp.15-18
    • /
    • 2007
  • This study investigated disinfection effect by general water purifier and water purifier with UV light disinfection. The results are as follows : (i) The general bacteria existed plentifully in a storage tank before treatment (ii) Water treated in water purifier did not meet the water treatment regulation standard since the presence of bacteria, whereas with UV light application the regulation standard is totally satisfied. (iii) Photocatalytic disinfection process with UV light in the presence of $TiO_2$ more effectively killed general bacteria than UV light only.

  • PDF

일부 농촌지역의 오염원 현황과 먹는 물 수질에 관한 조사연구 (A Study on the Drinking Water Quality and Contamination Sources in a Rural Area)

  • 김탁수;이용미;김문선;김성연;신해철;최경호;정문호
    • 한국환경보건학회지
    • /
    • 제30권2호
    • /
    • pp.98-103
    • /
    • 2004
  • To evaluate the quality of drinking water and contamination sources in a rural community, this study was carried out on the summer of 2003 at Shin-Dong Myun, Chun-Cheon, Gang-Won province. Seventy three drinking water samples were collected from three different types of water supply systems. Sources of contamination were identified and the public perception of water quality area were evaluated. The findings of this study are as follows; Drinking water was mainly obtained from Local Water and Simple Piped Water Supply Systems, and pollution sources varied over the study area. Most of residents (>63%) were satisfied with the quality of drinking water and could not identify any contamination sources. Corresponding to this perception, measured water quality parameters generally met the Drinking Water Quality Standards (>64%). However, approximately 35.6% of samples exceeded the regulation for Nㅒ$_3$$^{-}$$_{-}$N, coliform, and general bacteria. The water quality was significantly different among the three water supply systems, and between the potentially contaminated areas and the rest of the areas (p<0.05). In the potentially contaminated areas, the levels of coliform and general bacteria contamination were significantly higher than the rest of the areas (p<0.05). The coliform and general bacteria values of Simple Piped Water were significantly higher than Own Piped Water's, and the NO$_3$$^{-}$$_{-}$N values of Own Piped Water were significantly higher than those of water's (p<0.05). Based on this study, NO$_3$$^{-}$$_{-}$N, coliform, and general bacteria were identified as a major problem of drinking water. To regularly manage drinking water supply systems, to identify contamination sources, and to add drainage systems are required in the study area.

가정용 정수기의 수질에 대한 위생학적 조사 소견 (A Sanitary Survey on the Clean Water by Domestic Purifier)

  • 채용곤
    • 환경위생공학
    • /
    • 제5권1호
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

Paint Removal of Airplane & Water Jet Application

  • Xue, Sheng-Xiong;Chen, Zheng-Wen;Ren, Qi-Le;Su, Ji-Xin;Han, Cai-Hong;Pang, lei
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권3호
    • /
    • pp.125-129
    • /
    • 2014
  • The paint removal and recoating are the very important process in airplane maintenance. The traditional technology is to use the chemical way corroding the paint with paint remover. For changing the defects, corrosion & pollution & manual working, of the traditional technology, the physical process which removes the paint of airplane with 250MPa/250kW ultra-high pressure rotary water jetting though the surface cleaner installed on the six axes robot is studied. The paint layer of airplane is very thin and close. The contradiction of water jetting paint removal is to remove the paint layer wholly and not damage the surface of airplane. In order to solve the contradiction, the best working condition must be reached through tests. The paint removal efficiency with ultra-high pressure and move speed of not damaged to the surface. The move speed of this test is about 2m/min, and the paint removal efficiency is about $30{\sim}40m^2/h$, and the paint removal active area is 85-90%. No-repeat and no-omit are the base requests of the robot program. The physical paint removal technology will be applied in airplane maintenance, and will face the safety detection of application permission.

Effect of hydrogen-rich water on the lactic acid level in metformin-treated diabetic rats under hypoxia

  • Zhao, Chuan;Guo, Yushu;Wang, Ruoxi;Cheng, Cheng;Chen, Xiangmei
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제25권6호
    • /
    • pp.517-523
    • /
    • 2021
  • The present study aims to investigate the impact of hydrogen-rich water on the lactic acid level in metformin-treated diabetic rats under hypoxia. Thirty Sprague-Dawley rats were randomly divided into five groups, including normal diet group, and diabetes model (DM) group, DM + metformin treatment (DMM) group, DMM + hypoxia treatment (DMMH) group and DMMH + hydrogen-rich water (DMMHR) group. We found that the levels of lactic acid, pyruvate and lactate dehydrogenase were significantly lower in the blood of DMMHR group than DMMH group. Superoxide dismutase and glutathione levels in liver and heart were significantly higher in DMMH group after hydrogen-rich water treatment, while malondialdehyde and oxidized glutathione levels were decreased in DMMHR group when compared with DMMH group, which indicates that hydrogen-rich water could reduce oxidative stress. qPCR analysis demonstrated that that pro-apoptotic genes Bax/Caspase-3 were upregulated in DM group and metformin treatment suppressed their upregulation (DMM group). However, hypoxic condition reversed the effect of metformin on apoptotic gene expression, and hydrogen-rich water showed little effect on these genes under hypoxia. HE staining showed that hydrogen-rich water prevented myocardial fiber damages under hypoxia. In summary, we conclude that hydrogen-rich water could prevent lactate accumulation and reduce oxidant stress in diabetic rat model to prevent hypoxia-induced damages. It could be served as a potential agent for diabetes patients with metformin treatment to prevent lactic acidosis and reduce myocardial damages under hypoxic conditions.

비음용 지하수 오염물질 기준설정체계 구축 연구: (2) 일반오염물질 (Establishment of Non-drinking Groundwater Quality Standards: General Contamination Substances)

  • 안윤주;남선화;정승우
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권6호
    • /
    • pp.24-29
    • /
    • 2014
  • To data, there was no systematic basis for establishing the content and allowed levels of general contamination substances in the Korean groundwater quality standards for non-drinking water. Recently, use of specific procedures for deriving valid groundwater quality standards have become mandatory. This study first investigated the methodology for deriving groundwater quality standards in the European Commission (EC), considering background groundwater quality and domestic and international standards related to water quality. Furthermore, this study investigated the existing specified procedure of standards related to water quality (e.g. surface water, drinking water, and wastewater). Our findings showed that EC and Member States presented the methods for deriving groundwater threshold values for general chemicals. Finally, we have proposed the following procedures of deriving Korean groundwater quality: (1) Selection of groundwater pollutant population, (2) selection and monitoring of priority substances, (3) monitoring, (4) selection of groundwater quality standard candidates, (5) selection of new substances and values for groundwater quality standards.

전기영동 겔과 녹차성분에 대한 환원전리수의 침투력과 용해력 (Permeability and Dissolvability of Cathodic Electrolyzed Water for Electrophoretic Gel and Green Tea Components)

  • 류근걸;이윤배;이종권;이미영
    • 한국산학기술학회논문지
    • /
    • 제6권1호
    • /
    • pp.87-93
    • /
    • 2005
  • 본 연구에서는 전기영동 겔에 대한 환원전리수의 침투력과 녹차성분에 대한 환원전리수의 용해력을 일반 물과 서로 비교하였다. 환원전리수로 제조한 CBB-R 염색시약으로 polyacrylamide 겔 상에서 단백질을 다양한 시간 동안 염색한 후, 증류수로 제조한 CBB-R 염색시약에 의한 염색강도와 서로 비교하였다. 그 결과 환원전리수로 제조한 CBB-R 염색시약은 증류수로 제조한 CBB-R 염색시약보다 먼저 단백질을 강하게 염색시켰다. 뿐만 아니라 $25^{\circ}C$에서 환원전리수는 일반 물에 비하여 녹차성분에 대해 극히 탁월한 용해력을 나타내었다. 이러한 결과는 환원전리수가 일반 물보다 침투력과 용해력이 매우 강력하다는 것을 보여준다.

  • PDF