• Title/Summary/Keyword: Gauge block

Search Result 63, Processing Time 0.035 seconds

Reliability study of 6-axis model surgery simulator for orthognathic surgery (6축 모형수술 시뮬레이터의 정확도에 관한 연구)

  • Jeon, Jae-Ho;Lee, Hyung-Chul;Ji, Hyun-Jin;Jeon, Yeong-Jin;Kim, Yong-Il;Son, Woo-Sung;Park, Soo-Byung;Kim, Sung-Sik;Whang, Dae-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.1
    • /
    • pp.23-27
    • /
    • 2010
  • The purpose of this study was to evaluate the reliability of 6-axis model surgery simulator (6AMSS) for orthognathic surgery. A rectangular parallelepiped plastic block was assembled to model-mounting plate of 6AMSS. Left-right (X), anterior-posterior (Y), up-down (Z) translation and pitching (${\phi}X$), rolling (${\phi}Y$) and yawing (${\phi}Z$) rotation was planned and performed using 6AMSS. The actual translation and rotation were measured with dial gauge and precisional protractor, respectively. Comparison between the planned and actual movements of plastic block for each variable were made using paired t- test. Statistical analysis for X, Y, Z, ${\phi}X$, ${\phi}Y$ and ${\phi}Z$ movement have shown no significant differences between planned and actual movement (P > 0.05). This indicate that model surgery performed with the aid of the 6AMSS is accurate in 3D translation and rotation. The 6AMSS is practically useful for accurate fabrication of surgical splint for orthognathic surgery.

Spinal Anesthesia for Lower Extremities : Comparison of Plain 0.5% Bupivacaine and Hyperbaric 0.5% Tetracaine (하지수술을 위한 0.5% 순수 Bupivacaine 척추마취)

  • Song, Sun-Ok;Koo, Bon-Up
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.121-130
    • /
    • 1990
  • Plain 0.5% bupivacaine and hyperbaric 0.5% tetracaine were compared for spinal anesthesia in 40 patients undergoing operation of lower extremities. Lumbar puncture was performed with a 22 gauge spinal needle with the patient in the lateral recumbent position. The third lumbar interspace was chosen for the puncture, when a free flow of clear CSF was obtained, the local anesthetic solution (2.5ml of 0.5% bupivacaine or 2.0ml of hyperbaric 0.5% tetracaine) was injected at a rate of 0.1ml/sec without barbotage. After injection of anesthetics, clinical features were observed and compared between the two groups. The results were as follows : 1. The two groups were well matched for age, sex, height and weight. 2. In both groups, sensory block to $T_{12}$ dermatome was obtained within 4 minutes, mean maximal level of analgesia was $T_{6-7}$, and the mean time for maximal level was around 20 minutes. 3. The onset times of motor block were similar in both groups and complete motor block was obtained in all cases within 20 minutes. 4. The duration of analgesia above the $T_{12}$ dermatome was 3 hours, postoperative analgesia was 7 hours. These values were significantly prolonged than those of the tetracaine group(p<0.05). 5. The changes in systolic pressure in the bupivacaine group were significantly less than those of the tetracaine group(p<0.05). 6. The complications after spinal anesthesia were headache, numbness, urinary retention and backpain, and were no significant difference in both groups. From the obtained results, we concluded that plain 0.5% bupivacaine was a relatively satisfactory agent for spinal anesthesia for operation of lower extremities. The time of onset, height of block and the complications of postoperative period were similar in both groups. The advantages of plain 0.5% bupivacaine were less hypotension and long duration of analgesia.

  • PDF

A Newly Designed Contact Profiler for Microstructure (새로운 구조의 접촉식 미세구조 프로필러)

  • Choi, Dong-Jun;Choi, Jai-Seong;Choi, In-Mook;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.39-45
    • /
    • 2002
  • A simple and low cost stylus profiler made of ferrite cores is developed. The devised profiler consists of a contact probe, a measuring transducer, a signal processing unit, and a motorized stage. The contact probe attached to 4-bar spring maintains sufficient stiffness to protect disturbances. An overlap-area type inductive position sensing system is selected as a measuring transducer, which has high sensitivity, repeatability and linearity. The transducer is composed of coil bundles and ferrite cores which have good electromagnetic characteristics in spite of low cost. The repeatability of the profiler with the proposed inductive sensing system is better than 50nm. Experimental results are shown that the proposed profiler can measure the line or 3D profile of an object with sub-micron features.

A Total Spinal Anesthesia Developed during an Induction of an Epidural Block -A case report- (경막외차단 유도중 발생한 전척추마취 -증례보고-)

  • Park, Jung-Goo;Cheun, Jae-Kyu
    • The Korean Journal of Pain
    • /
    • v.8 no.1
    • /
    • pp.156-158
    • /
    • 1995
  • Total spinal anesthesia is a well documented serious life threatening complication which results from an attempted spinal or epidural analgesia. We had an accidental total spinal anesthesia associated with a cranial nerve paralysis and an eventual unconsciousness during epidural analgesia. A 45-year-old female with an uterine myoma was scheduled for a total abdominal hysterectomy under the epidural analgesia. A lumbar tapping for the epidural analgesia was performed in a sitting position at a level between $L_{3-4}$, using a 18 gauge Tuohy needle. Using the "Loss of Resistance" technique to identify the epidural space, the first attempt failed; however, the second attempt with the same level and the technique was successful. The epidural space was identified erroneously. However, fluid was dripping very slowly through the needle, which we thought was the fluid from the normal saline which was injected from the outside to identify the space. Then 20 ml of 2% lidocaine was administered into the epidural space. Shortly after the spinal injection of lidocaine, many signs of total spinal anesthesia could be clearly observed, accompanied by the following progressing signs of intracrainal nerve paralysis: phrenic nerve, vagus nerve, glossopharyngeal nerve and trigeminal nerve in that order. Then female was intubated and her respiration was controlled without delay. The scheduled operation was carried out uneventfully for 2 hours and 20 minutes. The patient recovered gradually in th4e reverse order four hours from that time.

  • PDF

Subarachnoid Morphine for Perianal Postoperative Pain Control (미양(微量) Morphine 지주막하(蜘蛛膜下) 주입(注入)에 의(依)한 항문각위술후(肛門脚圍術後) 제통효과(除痛效果)에 대(對)한 임상연구(臨床硏究))

  • Rhim, Hwa-Taeg;Lee, Yeong-Sik;Oh, Hung-Kun
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.98-102
    • /
    • 1988
  • In order to control the pain after hemorrhoidectomy and anal fistulectomy, 6 mg of 0.5% hyperbaric tetracaine without(control, group I) or wilt 0.3 mg(group II) or 0.5 mg (group III) of 0.1% morphine was injected with a 22 gauge spinal needle into the subarachnoid space through L 3-4 interspace of patients in lateral position. About 30 minutes in Fowler' sposition after injection, operation was performed in lithotomy position. All the patients who ha4 morphine showed remarkable relief of postoperative pain for an average of 27 hours. However, the dosage(0.3 or 0.5 mg) of morphine administered did not affect the duration of pain relief. Blood pressure, pulse rate and pupil size were unchanged in all patients. Dysuria after block developed for on average of 5,6, 13.2 and 14.6 hours in group I, II and III respectively. Most of these cases required urethral catheterization. Minor complications such as nausea, vomiting, itching, fever, burning sensation and paresthesia were observed 16.7, 20 and 20% of cases in group I, II and III respectively; however, no treatment was required.

  • PDF

Precision Length Metrology using the Optical Comb of Femtosecond Pulse Lasers (펨토초 레이저의 주파수 모드를 이용한 정밀 길이 측정)

  • Jin Jong-Han;Kim Young-Jin;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.216-219
    • /
    • 2005
  • In precision length measurements using optical interferometry based on homodyne or heterodyne principles, it is crucial to have frequency-stabilized monochromatic light sources. To the end, we investigate the possibility of utilizing the optical comb constituted by ultrashort femtosecond pulse lasers generated from a gain medium of titanium-doped aluminium oxide $(Ti:Al_2O_3)$. The optical comb is stabilized by locking to the caesium atomic clock, which allows all the modes of the comb to maintain an extremely high level of frequency stabilization to precision of one part in $10^{16}$. Then, high precision length measurements are realized by extracting a single or group of particularly wanted optical frequency components or by adopting a third-party light source locked to the comb. Required measurement system setup will be presented in detail along with experimental results.

  • PDF

Comparison of the Results of Ultrasound-guided Caudal Epidural Block - Herniated Intervertebral Disc vs Spinal Stenosis - (초음파를 이용한 미추 경막외 차단술의 결과 비교 - 추간판 탈출증과 척추관 협착증 -)

  • Kim, Young-Tae;Cho, Kyu-Jung;Ahn, Chi-Hoon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.105-112
    • /
    • 2014
  • Purpose: Ultrasound-guided epidural caudal block for low back pain and radiating pain is often performed in the treatment of outpatients. However, this procedure has a failure rate of up to 25% even when it performed by an experienced physician. The authors investigate the effectiveness of Ultrasound-guided epidural caudal block in patients related to disc herniation or spinal stenosis. Materials and Methods: Ultrasound-guided caudal epidural block was performed in 55 outpatients with LBP and radiating pain. Patient was placed in the prone position and sonographic image of sacral hiatus was obtained using linear probe. A 22-gauge needle was advanced into the sacrococcygeal membrane under ultrasound guidance and then medication was injected into the caudal epidural space. There were 31 cases of disc herniation, and 24 cases of spinal stenosis. Patients were evaluated by Visual Analog Scale (VAS) pain score at pre-treatment, post-treatment, 2 weeks and 4 weeks by telephone interviews. Results: 53 of the 55 cases (96.4%) of needle insertion into the sacral canal under ultrasound guidance were successful. Gender was not significantly different between disc herniation group and spinal stenosis group. But there was a significant age difference between disc herniation group ($42.3{\pm}10.8$), and spinal stenosis group ($62.8{\pm}15.1$) [p<0.001]. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in disc group were 6.84, 3.1, 1.8 & 1.77. The VAS score at pre-treatment, post-treatment, 2 weeks, 4 weeks in spinal stenosis group were 6.88, 3.58, 4.33 & 4.88. The VAS score in both groups was significantly improved after the procedure (p<0.001). Over time, the two groups were statistically significant differences in VAS score after adjusting for age (p<0.001). Conclusion: Ultrasound-guided caudal epidural block seems to provide a high success rate and a significantly better response in disc group than spinal stenosis group.

  • PDF

Heat Transfer Enhancement of Water Spray Cooling by the Surface Roughness Effect (표면거칠기 효과에 따른 스프레이 냉각의 열전달 향상 연구)

  • Lee, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.203-212
    • /
    • 2010
  • Water spray cooling has been widely used in a variety of industrial applications. The present study concentrated on quantitative measurements of the heat flux and heat transfer coefficient by water spray as it impinges on the rough surface of a hot steel plate at $900^{\circ}C$. A novel experimental technique was developed for a hightemperature heat flux gauge with a test block, cartridge heaters, and thermocouples that was used to measure the surface heat flux information on the hot steel plate for local heat flux measurements. The roles of the surface roughness on heat transfer are presented in this paper for well-characterized four rough surfaces with average rms roughness heights of $40-80{\mu}M$. The results show that the local heat transfer for rough surfaces is higher than that for a smooth surface. Heat transfer can be significantly increased by the presence of surface roughness elements, which can disrupt the thin thermal boundary layer. In addition, the heat transfer enhancement mechanism on a rough surface can be investigated by a different boiling regime.

Effect of vibratory stimulation on pain during local anesthesia injections: a clinical trial

  • Ghorbanzadeh, Sajedeh;Alimadadi, Hoda;Zargar, Nazanin;Dianat, Omid
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.40.1-40.10
    • /
    • 2019
  • Objectives: This study aimed to assess the effect of DentalVibe on the level of pain experienced during anesthetic injections using 2 different techniques. Materials and Methods: This randomized crossover clinical trial evaluated 60 patients who required 2-session endodontic treatment. Labial infiltration (LI) anesthesia was administered in the anterior maxilla of 30 patients, while inferior alveolar nerve block (IANB) was performed in the remaining 30 patients. 1.8 mL of 2% lidocaine was injected at a rate of 1 mL/min using a 27-gauge needle. DentalVibe was randomly assigned to either the first or second injection session. A visual analog scale was used to determine participants' pain level during needle insertion and the anesthetic injection. The paired t-test was applied to assess the efficacy of DentalVibe for pain reduction. Results: In LI anesthesia, the pain level was 12.0 ± 15.5 and 38.1 ± 21.0 during needle insertion and 19.1 ± 16.1 and 48.9 ± 24.6 during the anesthetic injection using DentalVibe and the conventional method, respectively. In IANB, the pain level was 14.1 ± 15.9 and 35.1 ± 20.8 during needle insertion and 17.3 ± 14.2 and 39.5 ± 20.8 during the anesthetic injection using DentalVibe and the conventional method, respectively. DentalVibe significantly decreased the level of pain experienced during needle insertion and the anesthetic injection in anterior LI and mandibular IANB anesthesia. Conclusions: The results suggest that DentalVibe can be used to reduce the level of pain experienced by adult patients during needle insertion and anesthetic injection.

Operation of Abomasal Displacement and Foreign Body Removal in the Rumen through the Right Flank Celiotomy (우측 겸부를 통한 제4위전위증 교정 수술과 제1위 절개 수술의 병행)

  • Cho, Jin-Haeng;Kim, Myung-Cheol;Jeong, Seong-Mok;Lee, Jae-Yeon;Shin, Beom-Jun
    • Journal of Veterinary Clinics
    • /
    • v.30 no.1
    • /
    • pp.80-85
    • /
    • 2013
  • Twenty one cows in Goyang and Paju cities were referred due to displacement of the abomasum and foreign body in the rumen. Omentopexy and rumenotomy through a right flank celiotomy were performed for treatment of abomasal displacement and the foreign body removal in the rumen. The right paralumbar fossa is clipped and prepared surgically. Local anesthesia is instituted by performing inverted L block. The abdomen was entered through 25 to 30 cm vertical incision in the right paralumbar fossa starting 4 to 5 cm ventral to the transverse processes of the lumbar vertebrae. A 14-gauge needle with rubber tubing attached is inserted to relieve the gaseous pressure and to facilitate further exploration and manipulation. The rumen was gently pulled out of the abdominal cavity and incision was made at the omentum. Rumenotomy was done and retrieved the foreign body. After the rumen was rinsed with sterile saline, the rumen wall was closed by a Lembert suture technique. The omentum was closed by a simple continuous suture. Right flank omentopexy was performed for the surgical correction of abomasal displacement. Recovery results among 21 cows included 9 excellent, 5 good, 2 fair and 5 bad. It was considered that operation of abomasal displacement and foreign body removal in the rumen through right flank celiotomy was a good surgical technique to reduce expenses, surgical pain, and surgery time.