• 제목/요약/키워드: Gating system

검색결과 160건 처리시간 0.022초

MRI용 심전도/혈류 게이팅 시스템 설계 (Design of ECG/PPG Gating System in MRI Environment)

  • 장봉렬;박호동;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

수모델 실험을 이용한 전통 탕구계의 유동 양상에 미치는 필터의 영향 연구 (A Study on the Effects of the Filter on Flow Pattern of the Traditional Gating System by the Water Modeling Experiment)

  • 황호영;남철희;최영심;홍준호
    • 한국주조공학회지
    • /
    • 제36권6호
    • /
    • pp.208-214
    • /
    • 2016
  • Casting defects, which are closely related to entrapped air bubbles and metallic oxides, occur very frequently in the casting process. Many researchers have shown that these defects can be reduced by adopting an appropriate gating system design. But, it is difficult for field engineers to identify a specific gating system that is more appropriate for their products. In this study, we tried to draw a comparison of gating system designs with and without ceramic foam filters. A ceramic foam filter was added to the horizontal runner just after the sprue to prevent air bubble generation and to reduce turbulence without change of the gating system design. To verify the effects of initial pouring velocity, the experiment was conducted with four different amounts of water volume in the reservoir. Results of the water modeling experiment applying the filter showed remarkably changed flow characteristics. Although the study confirmed that use of the filter may change the flow characteristics, it needs to be noted that only filter use alone cannot solve all the problems caused by a poorly designed gating system.

전차 파워팩에 적용되는 알루미늄 터보 팬의 주조방안 설계 및 주조 해석에 관한 연구 (A Study on the Design and Simulation of Sand Casting for Alumimum Turbo Fan in Tank Powerpack)

  • 진철규;이운길
    • 한국산업융합학회 논문집
    • /
    • 제25권5호
    • /
    • pp.889-898
    • /
    • 2022
  • In this study, sand casting process was applied to manufacture a large aluminum turbo-type fan used for tank powerpack. To apply the sand casting method, the turbo fan was reverse engineered, and after designing three gating systems, the optimal gating system design was selected by performing casting simulation. In the case of the bottom up-gating system, there is a significant temperature loss of the molten alloy during blade filling. When the molten alloy is completely filled into the sand mold, the blade upper tip and front shroud are below the liquidus temperature. In the case of the top down-gating system, molten alloy scattering occurs, but the temperature loss while the blade is filled is smaller than that of the bottom up type. And after the inflow of molten alloy into the mold is completed, the blade upper tip and front shroud are higher than the liquidus temperature. A sand mold was manufactured with the top down-gating system and the casting process was performed. The fan was made perfectly in appearance without any unfilled parts.

호흡동조 방사선치료에 사용되고 있는 RPM (Real-time Position Management) Respiratory Gating System의 호흡변화에 따른 정확성에 대한 고찰 (Consideration of the Accuracy by Variation of Respiration in Real-time Position Management Respiratory Gating System)

  • 나준영;강태영;백금문;권경태
    • 대한방사선치료학회지
    • /
    • 제25권1호
    • /
    • pp.49-55
    • /
    • 2013
  • 목 적: 본원에서 시행하고 있는 호흡동조 방사선치료(Respiratory Gated Radiation Therapy, RGRT)는 RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA)을 이용하여 실시하고 있다. 본 연구는 호흡변화에 따른 방사선치료의 정확성을 분석하고 평가하고자 한다. 대상 및 방법: 움직임을 임의로 조정할 수 있는 구동 팬텀(Motion Phantom)인 QUASAR Programmable Respiratory Motion Phantom (Moudus Medical Device Inc. CANADA)을 이용하였다. 폐암과 간암 환자 50명의 호흡을 분석하여 호흡의 변화를 관찰한 결과를 기준으로 주기 3초, 진폭 1.5 cm인 총 60초간의 기준호흡에서 매번 기저호흡(Baseline)을 기울기를 갖고 점진적으로 내려가는 경우와, 간헐적으로 기준 기저호흡 보다 더 내려가는 경우의 호흡 모양을 만들어 본원에서 사용되고 있는 Phase gating, 보통 30~70% gating 치료 방법과 동일하게 방사선을 조사하였다. 결 과: 점진적으로 매번 기저호흡이 0.01 cm, 0.03 cm, 0.05 cm씩 내려가는 호흡의 경우 모든 조건에서 방사선이 조사되었다. 간헐적으로 기저호흡이 0.2 cm, 0.4 cm, 0.6 cm, 0.8 cm 내려가는 경우도 모든 조건에서 방사선이 조사되어 RPM Respiratory Gating System에서 Phase gating 방식은 기저호흡 변화에 대하여 방사선이 모두 조사되었다. 결 론: 최적의 방사선치료를 위해 종양의 움직임을 고려하여 시행하는 호흡동조 방사선치료에서 RPM Respiratory Gating System의 Phase gating 방식은 본 연구에서와 같이 기저호흡의 변화가 호흡동조에 정확히 반영되지 않음을 알 수 있었다. 이에 호흡동조 방사선치료에는 무엇보다 환자의 호흡 관찰이 중요하다고 사료되며 호흡의 변화가 관찰되었다면 즉시 방사선치료를 멈추고 호흡을 관찰한 후 변화된 호흡상태에서 투시를 시행하여 치료부위를 다시 확인한 후에 치료를 재개하여야 한다고 사료된다.

  • PDF

흐름 적응 탕구계와 필터가 유동 안정성에 미치는 영향 연구 (A Study on the Effects of Flow Adaptive Gating System and Ceramic Filter on Flow Stability)

  • 황호영;윤송;남철희
    • 한국주조공학회지
    • /
    • 제37권3호
    • /
    • pp.71-77
    • /
    • 2017
  • Casting defects produced during the casting process seriously affect the mechanical properties of the resulting products, reduce the performance capabilities of the product, and also result in economic losses. Therefore, this paper mainly investigates the causes of defects and methods by which to reduce these defects stemming from molten metal flows in a runner system of the type widely used in the sand mold casting process. The flow characteristics of a molten alloy are difficult to observe during the actual casting process. For this reason, a water model was used to observe the flow in the casting process, and the flow in each case was recorded using high-speed cameras as part of the experimental process of this study. Several repetitive experiments were performed to improve the accuracy of the experimental results. The traditional casting system was modified according to the design rules proposed by Campbell, and the system was termed flow-adaptive gating system with a water model. Comparing the flow characteristics of traditional and adaptive gating systems with a water model shows that the bubbles in the water in the latter case are reduced more significantly than in the former case. A ceramic filter system was adapted to the flow-adaptive gating system to minimize the instability of the flow during filling, which occurs as the fluid velocity in the runner increases. In additional, the flow behavior with and without the filter system were compared. The water model system in this work was shown to be able to verify that the adaptation of the filter system brings improvements by stabilizing the flow and reducing the amount of bubbles in the runner system. Moreover, using the flow-adaptive runner system with the filter system leads to considerably stable flows in the runner system.

Self-Power Gating Technique For Low Power Asynchronous Circuit

  • Mai, Kim-Ngan Thi;Vo, Huan Minh
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.548-557
    • /
    • 2018
  • In this paper, Asynchronous Self-Power Gating technique (ASPG) is used to reduce consumption power in asynchronous digital watch application. The power gating control signal is automatically generated by internal system operation characteristics instead of using replica circuit delay or four-phase handshaking protocol. Isolation cell is designed to insert it between power gating domain and normal operation domain. By using self-power gating circuit, asynchronous digital watch application consumes very low power and maintains data during sleep mode. The comparison results show the proposed ASPG technique saves leakage power up to 40.47% and delay time is reduced to 71% compared to the conventional circuit.

A Study on the Design of Gating System for Semi-Solid Diecasting Process

  • Park, Chul-Woo;Kim, Young-Ho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제4권2호
    • /
    • pp.39-48
    • /
    • 2003
  • In the Semi-Solid Diecasters design, a Seni-Solid Diecasters experiment has usually been carried out before producing new casts. At the Semi-Solid Diecasting stages, the runner-gate part has been always repeatedly corrected, which leads to a tedious processing time and high processing cost. Much experience is essential in manual assessment and if the design is defective, much time and a great deal of efforts will be wasted in the modification of the die. In this study, a design system has been developed based on the design database In addition, a gate experiment for the gating system design has been tarried out to append the database. It is possible for engineers to make efficient gating system design of Semi-Solid Diecasting and it will result in the reduction of expenses and time to be required.

이동형 시스템에서 프로세서의 전력 소모 최소화를 위한 주파수 선택 알고리즘 (A Frequency Selection Algorithm for Power Consumption Minimization of Processor in Mobile System)

  • 김재진;강진구;허화라;윤충모
    • 디지털산업정보학회논문지
    • /
    • 제4권1호
    • /
    • pp.9-16
    • /
    • 2008
  • This paper presents a frequency selection algorithm for minimization power consumption of processor in Mobile System. The proposed algorithm has processor designed low power processor using clock gating method. Clock gating method has improved the power dissipation by control main clock through the bus which is embedded clock block applying the method of clock gating. Proposed method has compared power consumption considered the dynamic power for processor, selected frequency has considered energy gain and energy consumption for designed processor. Or reduced power consumption with decreased processor speed using slack time. This technique has improved the life time of the mobile systems by clock gating method, considered energy and using slack time. As an results, the proposed algorithm reduce average power saving up to 4% comparing to not apply processor in mobile system.

게이트 수에 따른 주물재의 특성 분석 (Effect of gate numbers on the characteristics cast)

  • 이성문;이혜경;이건엽;문성민;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.298-301
    • /
    • 2009
  • In this study, the casting process using forged insert was investigated to characterize the manufacturing process by which good mechanical properties can be obtained when compared with existing casting products. Process analysis for the casting design was performed by using FVM (Finite Volume Method) software. In filling process, three kinds of candidate gating systems are considered and analyzed respectively. The molten metal behavior in gating system is so important that it affects the solidification behavior of the cast.

  • PDF

Development of a Real-Time Internal and External Marker Based Gating System for Proton Therapy

  • Cho, Junsang;Cheon, Wonjoong;Ahn, Sanghee;Lee, Moonhee;Park, Hee Chul;Han, Youngyih
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.92-99
    • /
    • 2017
  • In respiratory-induced proton therapy, the accuracy of tracking system and beam controlling is more important than photon therapy. Therefore, a high accuracy motion tracking system that can track internal marker and external surrogate is needed. In this research, our team has installed internal and external marker tracking system at our institution's proton therapy system, and tested the scanning with gating according to the position of marker. The results demonstrate that the developed in-house external/internal marker based gating system can be clinically used for proton therapy system for moving tumor treatment.