• 제목/요약/키워드: Gas-gas heater

검색결과 304건 처리시간 0.024초

국내 현장중온재생공법의 프리히터 개발을 위한 기초연구 (Fundamental Study for Development of Pre-Heater for Warm In-Place Recycling in Korea)

  • 김대훈;김승훈;권수안;김용주;이재준
    • 한국도로학회논문집
    • /
    • 제17권2호
    • /
    • pp.31-37
    • /
    • 2015
  • PURPOSES : To design a pre-heater for warm in-place recycling equipment, three different heating systems were evaluated to determine their thermal efficiency. METHODS: In this study, a $30cm{\times}30cm{\times}15cm$ wheel-tracking specimen was used to measure the inner temperature as a function of the heating system. The inner temperature of the specimen was measured with a data logger at the surface, and at depths of 1cm, 2cm, 3cm, 4cm, and 5cm. To evaluate the thermal efficiency, the researchers used three different types of equipment, namely, IR, a heating wire, and a gas burner. RESULTS: The IR heating system exhibits a higher level of performance than the others to achieve the target temperature at a depth of 5cm in the specimen. The gas burner system was capable of heating the surface to a temperature of up to $600^{\circ}C$. The other types, however, cannot heat the surface up to 600. The thermal efficiencies were measured based on the laboratory conditions. CONCLUSIONS: To find the most effective system for application to the development of a pre-heater for warm in-place recycling, various systems (IR, heating wire, gas burner) were examined in the laboratory. As a result, it was found that the hot plate of a gas burner system provides the highest temperature at the surface of the asphalt but, of all the systems, the IR system provides the best internal temperature increase rate. Furthermore, a gas burner can age the asphalt binder of the surface layer as a result of the high temperature. However, the gas burner cannot attain the target temperature at 5cm. The IR system, on the other hand, is effective at increasing the internal temperature of asphalt.

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

흡수식 냉온수기용 저 NOx 가스버너 개발 (Development of Low NOx Gas Burner Absorption Chiller/Heater Unit)

  • 최정환;오신규
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.277-283
    • /
    • 1995
  • For the development of low NO$_{x}$ gas burners aimed for absorption chiller/heater unit, three proto type burners of different capacity (265000, 498000, and 664000 kcal/h) have been manufactured through a combustion method of step-by-step air injection. In order to characterize the overall features of the flame and the properties of the emission gas, the temperature of the flame and the concentration of NO$_{x}$ and CO were determined. The main factors in the design of burners (the area of primary air injection, the diameter of secondary air injection hole, fuel nozzle diameter) were observed to increase linearly with the scale-up of burner capacity. The flame temperature profiles of the burners were observed to be almost similar, irrespective of their capacity. However, as their capacity increased, the flame temperature slightly increased and the hot region of the flames moved to ward the flame tip along with the expansion to the direction of radius. From the proto type units, the amount of their NO$_{x}$ emission was determined to be around 25 - 30 vppm(3% )$_{2}$) and the CO emission was less than 19 vppm (3% $O_{2}$).TEX>).

Pt/Ti 발열체가 내장된 TMA 가스 측정용 ZnO 박막 가스 센서 (ZnO thin film Gas sensors for detection of TMA gas with Pt/Ti thin film heater)

  • 류지열;박성현;최혁환;권태하
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.127-135
    • /
    • 1996
  • To increase the sensitivity and the selectivity of the sensors to TMA gas, the composition ratio and the growth conditions of the ZnO films are studied. Annealing of the ZnO films in the various time ranges and temperatures in the oxygen is carried out to enhance the stbility of the electrical resistance. Pt/Ti heater deposited on backside of the substrates in used to control the operating temperature of th esensor. The ZnO thin film sensors doped to 4.0 wt% $Al_{2}$O$_{3}$ 1.0wt.% TiO$_{2}$ and 0.2wt.% V$_{2}$O$_{5}$ exhibited a high sensitivity and an excellent selectivity for TMA gas. The sensors made with the thin films annealed at 700$^{\circ}$C for 60 minutes in the oxygen atmosphere had a good stability and linearity. The heater deposited in the ratio of 1 to 1 (Pt:Ti) had a good heating properties. The sensors fabricated using above conditions showed a good response to the actual gases of a mackerel at a step of deterioration after death.

  • PDF

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

가스히터의 소음 진동 원인 분석 (A cause analysis of Noise & Vibration of Gas Heater)

  • 고재필;유현석
    • 한국가스학회지
    • /
    • 제13권1호
    • /
    • pp.9-13
    • /
    • 2009
  • 가스히터의 가동으로 인하여 발생하는 소음 및 진동의 주 원인은 연소음(combustion roar)과 연소진동음(combustion oscillation)이다. 연소음(combustion roar)의 특징은 음압이 넓은 주파수대에 걸쳐 있고, 크기도 비교적 일정 하다. 반면 연소진동음(combustion oscillation)은 연소실내 기체의 고유진동수에 대하여 버너계가 Positive Feedback을 일으켜 공진할 때 발생되는 소음 및 진동이다. 따라서 소음 및 진동을 해결 할 수 있는 방법은, 공진을 피하는 것이다. 첫 번째, 버너에서 연료와 공기량의 비율을 조절하여 진동수를 변화시키거나, 연소실내에서의 연료와 공기의 혼합속도를 변화시키는 방법이 있다. 두 번째, 연소실의 길이나 이코노마이저(Economizer)의 형상을 바꾸어 고유진동수를 변경시키는 방법이 있다. 본 논문에서는 이코노마이저(Economizer)를 변경하여 공명을 회피하였다.

  • PDF

가스온수가열기의 용량에 따른 에너지효율성 비교 연구 (A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler)

  • 김성중;우인성
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.

H2S Micro Gas Sensor Based on a SnO2-CuO Multi-layer Thin Film

  • Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권1호
    • /
    • pp.27-30
    • /
    • 2012
  • This paper proposes a micro gas sensor for measuring $H_2S$ gas. This is based on a $SnO_2$-CuO multi-layer thin film. The sensor has a silicon diaphragm, micro heater, and sensing layers. The micro heater is embedded in the sensing layer in order to increase the temperature to an operating temperature. The $SnO_2$-CuO multi layer film is prepared by the alternating deposition method and thermal oxidation which uses an electron beam evaporator and a thermal furnace. To determine the effect of the number of layers, five sets of films are prepared, each with different number of layers. The sensitivities are measured by applying $H_2S$ gas. It has a concentration of 1 ppm at an operating temperature of $270^{\circ}C$. At the same total thickness, the sensitivity of the sensor with multi sensing layers was improved, compared to the sensor with one sensing layer. The sensitivity of the sensor with five layers to 1 ppm of $H_2S$ gas is approximately 68%. This is approximately 12% more than that of a sensor with one-layer.

계획예방정비가 발전소 공기예열기의 성능에 미치는 영향 (Effect of Preventive Maintenance on Performance of Air Heater in a Power Plant)

  • 장진형;홍은기;황광원;윤린
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.465-469
    • /
    • 2010
  • 발전설비 내 공기예열기는 보일러 연소가스로부터 열을 회수하여 유효열의 손실을 감소시킴으로서 보일러의 열효율을 높이기 위해 설치된다. 본 연구에서는 계획예방정비가 공기예열기의 성능에 미치는 영향을 고찰하였다. 공기예열기의 성능지표들은 공기예열기의 계획예방정비 전후의 운전 상태와 성능변화 모두를 고려하여 계산되었고, 공기예열기의 중요한 성능지표로는 가스 측 온도효율, 공기누설률, 열회수율, 열관류율과 열용량비들이다. 계획예방정비 전후의 공기예열기 성능평가로부터 공기예열기의 모든 성능 지표가 계획예방정비 후 향상되었다.