DOI QR코드

DOI QR Code

Effect of Preventive Maintenance on Performance of Air Heater in a Power Plant

계획예방정비가 발전소 공기예열기의 성능에 미치는 영향

  • 장진형 (한국전력 전력연구원) ;
  • 홍은기 (한국전력 전력연구원) ;
  • 황광원 (한국전력 전력연구원) ;
  • 윤린 (한밭대학교 기계공학과)
  • Received : 2009.06.29
  • Accepted : 2010.02.18
  • Published : 2010.05.01

Abstract

Air heater used in power plant helps increase the thermal efficiency of the boiler by recovering the heat from the boiler flue gas and thus preventing the loss of useful heat. This study investigates the effect of preventive maintenance on the performance of the air heater in a power plant. Performance indexes for the air heater are calculated to observe the changes in the performance and operation status of the air heater before and after preventive maintenance. The major performance indexes considered are temperature efficiency of the flue gas side, air leakage rate, heat recovery rate, heat transmission rate, and heat capacity ratio. The performance of the air heater is evaluated before and after preventive maintenance; our results show that all the abovementioned performance indexes are improved after the maintenance.

발전설비 내 공기예열기는 보일러 연소가스로부터 열을 회수하여 유효열의 손실을 감소시킴으로서 보일러의 열효율을 높이기 위해 설치된다. 본 연구에서는 계획예방정비가 공기예열기의 성능에 미치는 영향을 고찰하였다. 공기예열기의 성능지표들은 공기예열기의 계획예방정비 전후의 운전 상태와 성능변화 모두를 고려하여 계산되었고, 공기예열기의 중요한 성능지표로는 가스 측 온도효율, 공기누설률, 열회수율, 열관류율과 열용량비들이다. 계획예방정비 전후의 공기예열기 성능평가로부터 공기예열기의 모든 성능 지표가 계획예방정비 후 향상되었다.

Keywords

References

  1. KEPRI R&D center, 1983, Air-heater, Korea Electric Power Research Institute.
  2. ASME PTC Performance Test Code 4.3 "Air Heater," 1993, ASME, New York.
  3. KEPRI Power Generation Laboratory, 1996, Guidebook for Analyzing Thermal Powerplant, Korea Electric Power Research Institute.
  4. ASME PTC Performance Test Code 4 "Boiler," 1998, ASME, New York.
  5. KEPRI Power Generation Laboratory, 2007, Guidebook for Analyzing Thermal And Combined Cycle Power Plant, Korea Electric Power Research Institute.