• Title/Summary/Keyword: Gas sensitivity

Search Result 966, Processing Time 0.028 seconds

A study on the $NO_2$ gas detection characteristics of the CuTBP(Copper-tetra-tert-butylphthalocyanine) chemiresistor device (CuTBP(Copper-tetra-tert-butylphthalocyanine) 화학 저항 장치의 $NO_2$ 가스 탐지 특성에 관한 연구)

  • 구자룡;이창희;김태완;김정수
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.233-238
    • /
    • 1997
  • We have investigated gas-detection characteristics of CuTBP (Copper-tetra-tert-butylphthalocyanine) chemiresistor devices exposed to air/200ppm N $O_{2}$ gases. The CuTBP films were made by Langmuir-Blodgett (LB) techniques. Sensitivity, response time, recovery time, and reproducibility of the devices were measured by current voltage characteristics. Interdigital electrode was used to improve the sensitivity. It was observed that a conductance G increases monotonically as the number of interdigital electrode finger pairs increases. As the number of interdigital electrode finger pairs increases, the sensitivity S( $G_{gas}$/ $G_{air}$) increases more than 50 times and stable. But the response time was delayed. The average recovery time of the CuTBP chemiresistor devices turned out to be about 100 second. We have also investigated applicability of the CuTBP chemiresistor device for a gas sensor.sor.

  • PDF

Effects of Substrate on the Characteristics of SnO2 Thin Film Gas Sensors (기판 종류에 따른 박막형 SnO2 가스 센서의 응답특성)

  • Kim, Seon-Hoon;Park, Shin-Chul;Kim, Jin-Hyuk;Moon, Jong-Ha;Lee, Byung-Teak
    • Korean Journal of Materials Research
    • /
    • v.13 no.2
    • /
    • pp.111-114
    • /
    • 2003
  • Effects of substrate materials on the microstructure and the sensitivity of $SnO_2$thin film gas sensors have been studied. Various substrates were studied, such as oxidized silicon, sapphire, polished alumina, and unpolished alumina. It was observed that strong correlation exists between the electrical resistance and the CO gas sensitivity of the manufactured sensors and the surface roughness of $SnO_2$thin films, which in turn was related to the surface roughness of the original substrates. X$SnO_2$thin film gas sensor on unpolished alumina with the highest surface roughness showed the highest initial resistance and CO gas sensitivity. The transmission electron microscopy observation indicated that shape and size of the columnar microstructure of the thin films were not critically affected by the type of substrates.

Effect of Intermediate Metal on the Methanol Gas Sensitivity of ITO Thin Films (층간금속층에 따른 ITO 박막의 메탄올 검출민감도 개선 효과)

  • Lee, H.M.;Heo, S.B.;Kong, Y.M.;Kim, Dae-Il
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.195-199
    • /
    • 2011
  • ITO thin films and gold (Au), copper (Cu) and nickel (Ni) intermediate ITO multilayer (ITO/Au/ITO, ITO/Cu/ITO, ITO/Ni/ITO) films were deposited on glass substrates with a reactive radio frequency and direct current magnetron sputtering system and then the effect of intermediate metal layer and annealing temperature on the methanol gas sensitivity of ITO films were investigated. Although both ITO and ITO/metal/ITO (IMI) film sensors have the same total thickness of 100 nm, IMI sensors have a sandwich structure of ITO 50 nm/metal 10 nm/ITO 40 nm. The change in the gas sensitivity of the film sensors caused by methanol gas ranging from 100 to 1000 ppm was measured at room temperature. The IAI film sensors showed the higher sensitivity than the other sensors. Finally, it is concluded that the ITO 50/Au 10/ITO 40 nm film sensors hasthe potential to be used as improved methanol gas sensor.

Sensing characteristics of polyaniline sensor coated with porous PVDF layers to methanol gas under various humidity conditions (다공성 PVDF막이 코팅된 Polyaniline 센서의 다양한 습도분위기의 메탄올 가스에 대한 감응특성)

  • Lim, Cheol-Beom;Sohn, Sung-Ok;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.205-210
    • /
    • 2006
  • Hydrophobic polymer [ex. Poly(vinylidenfluoride)] layer was coated on polyaniline (PANi) sensor to reduce the contamination humidity. The differences in sensitivity to methanol gas detection in various humidity condition between pure-PANi sensor and sensor coated with poly(vinylidenfluoride) polymer (PVDF) (coated-PANi sensor) were investigated. Considering the relation between the density of pore, which was coated on the layer of the PANi sensor, and sensitivity was investigated. To fabricate the porous PVDF layer on PANi sensor, poly(vinylalcohol) (PVA), which is water-soluble polymer, was used. Coated-PANi sensor was less affected by humidity compared with pure-PANi sensor. And higher density of pore on PVDF layer led to higher sensitivity.

NO Gas Sensor with Enhanced Sensitivity Using Activated Carbon Prepared from Pyrolysis Fuel Oil and Polyethylene Terephthalate (열분해 연료유 및 PET 기반 활성탄을 이용한 NO 가스 센서의 감도 향상 연구)

  • Kwak, Cheol Hwan;Seo, Sang Wan;Kim, Min Il;Im, Ji Sun;Kang, Seok Chang
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.42-48
    • /
    • 2021
  • In this study, a sensor for detection of nitric oxide (NO) gas was developed using petroleum pitch-based activated carbon which was synthesized from pyrolysis fuel oil (PFO). Polyethylene terephthalate (PET) was added to increase molecular weight by stimulating a polymerization of components in PFO during the pitch synthesis process. The increase in the molecular weight of pitch contributed to the improvement of textural properties of activated carbon, such as the specific surface area and micropore volume. It also enhanced the sensitivity of NO gas sensor based on the activated carbon. In addition, the effect of PET addition during the pitch synthesis on the surface oxygen content and conductivity of activated carbon was investigated. Finally, the correlation of the sensitivity with physical properties of activated carbon was analyzed.

Uncertainty Assessment Using Monte Carlo Simulation in Gas Flow Measurement (기체 유량 측정에서 몬테 카를로 모사를 이용한 측정불확도 평가)

  • Lee, Dae-Sung;Yang, In-Young;Kim, Chun-Taek;Yang, Soo-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1758-1765
    • /
    • 2003
  • Monte Carlo simulation(MC) method was used as an uncertainty assessment tool for gas flow measurement in this paper. Uncertainty sources for gas flow measurement were analyzed, and probability distribution characteristics of each source were discussed. Detailed MC methodology was described including the effect of the number of simulation. The uncertainty result was compared with that of the conventional sensitivity coefficient method, and it was revealed that the results were different from each other for this particular gas flow measurement case of which the modelling equation was nonlinear. The MC was comparatively simple, convenient and accurate as an uncertainty assessment method, especially in cases of complex, nonlinear measurement modelling equations. It was noted that the uncertainty assessment method should be selected carefully according to the mathematical characteristics of the measurement.

Development of PZT Piezoelectric Biosensor for the Detection of Formaldehyde (Formaldehyde 측정을 위한 PZT 압전 바이오센서 개발)

  • 김병옥;곽성곤;임동준
    • KSBB Journal
    • /
    • v.13 no.5
    • /
    • pp.477-482
    • /
    • 1998
  • A biosensor with PZT piezoelectric ceramic crystal was developed for the detection of formaldehyde gas. Poled PZT piezoelectric ceramic disk was made from ZrO2, TiO2 and Nb2O5, together with the addition of PbO and polyvinyl alcohol, through various processes of mixing, calcination drying, crushing, forming, sintering, polishing, ion coating and poling. Oscillator circuit of sensor was made of operational amplifier(AD811AN). Formaldehyde dehydrogenase was immobilized onto a piezoelectic ceramic crystal, together with the cofactors, reduced glutathione and nicotinamide adenine dinucleotide. The effect of flow rate on the sensitivity was determined by varing the flow rate of carrier gas from 24.7mL/min to 111.7mL/min through detector cell. The results indicated that as the flow rate was increased, the recovery rate was increased. And a significant increase in the sensitivity was observed in enhanced flow rate of carrier gas. Frequency difference(ΔF) of immobilized PZT piezoelectic disk increased proportionally to the concentration gas and reproduced to repeated exposures of formaldehyde gas(28ppm, Δ68Hz).

  • PDF

CO Gas Sensing Characterstics and Electrical Properties of $SnO_2-TiO_2$ Composite Ceramics ($SnO_2-TiO_2$ 세라믹 복합체의 일산화탄소 감응특성 및 전기적 성질)

  • 갬태원;최우성;정승우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.453-457
    • /
    • 1998
  • In order to improve CO gas sensitivity, $TiO_2$added $SnO_2$ composite ceramics were prepared. Using XRD and SEM, the phases and micro structures of these ceramics were investigated. The resistances as a function of gas atmosphere were measured by High Voltage Measure/Source Unit. The maximum 100 ppm CO gas sensitivities of $SnO_2-TiO_2$composites were 2.5 times larger than that of pure $SnO_2$ composite and showed the obvious temperature dependence of sensitivities in 500, 100 ppm CO gas atmospheres.

  • PDF

Fabrication of low power NO micro gas senor by using CMOS compatible process (CMOS공정 기반의 저전력 NO 마이크로가스센서의 제작)

  • Shin, Han-Jae;Song, Kap-Duk;Lee, Hong-Jin;Hong, Young-Ho;Lee, Duk-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • Low power bridge type micro gas sensors were fabricated by micro machining technology with TMAH (Tetra Methyl Ammonium Hydroxide) solution. The sensing devices with different heater materials such as metal and poly-silicon were obtained using CMOS (Complementary Metal Oxide Semiconductor) compatible process. The tellurium films as a sensing layer were deposited on the micro machined substrate using shadow silicon mask. The low power micro gas sensors showed high sensitivity to NO with high speed. The pure tellurium film used micro gas sensor showed good sensitivity than transition metal (Pt, Ti) used tellurium film.

Effects of Sulfate Ion the Gas Sensing Characteristic of the $\alpha$-Fe$_2$O$_3$ ($\alpha$-Fe$_2$O$_3$의 가스감지특성에 미치는 황산이온의 영향)

  • 양천희
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.71-74
    • /
    • 1989
  • The $\alpha$-Fe$_2$O$_3$ gas sensor, prepared by the precipitation of Fe(OH)$_3$ from a solution of iron(III) sulfate and tin (IV) chloride, was composed of fine particles and was superior in sensitivity to other $\alpha$-Fe$_2$O$_3$. The gas sensitivity was found to depend on the amounts of remaining sulfate ion the microstructure and a small amount of iron(II) species generated through the reduction of $\alpha$-Fe$_2$O$_3$. The sensing mechanism of $\alpha$-Fe$_2$O$_3$gas sensor was confirmed to be due to the reduction of $\alpha$-Fe$_2$O$_3$ to the low resistive Fe$_3$-xO$_4$ by combustible gas and to depend on the crystral structure.

  • PDF