Development of an Environmental Monitoring and Warning System for Cold Storage Rouse Using Internet (인터넷을 이용한 저온저장고 환경감시 및 경보 시스템 개발)

  • Jeong, Hoon;Yun, Hong-Sun;Lee, Won-Og;Cho, Kwang-Hwan;Cho, Young-Kil;Park, Won-Kyu;Shin, Jae-Hun
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.28-31
    • /
    • 2003
  • For safe storage of agricultural products in the cold storage house, accurate monitoring of temperature, humidity and gas conditions is necessary. This study was conducted to develop an environmental monitoring and warning system for the cold storage house to improve safety of storage. The system developed in this study is able to monitor temperature, humidity and $CO_2$concentration in the storage house and to send alarm signal to the farmer by telephone and beeper when abnormal conditions have been occurred in the storage house. And the developed system use internet network so we can supervise storage conditions in the home. From the results of the performance test, it was found that the temperature and relative humidity can be controlled within the range of 0.5$^{\circ}C$ and $\pm$2 percent. And farmer's response was fair.

Development of Analytical Method for Propylene Glycol in Foods (식품 중 프로필렌글리콜의 분석법 개발)

  • Kim, Hee-Yun;Hong, Ki-Hyoung;Choi, Jang-Duck;Park, Sung-Kwan;Jung, Si-Sub;Choi, Woo-Jeong;Lee, Shin-Ho;Moon, Dong-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.889-892
    • /
    • 2005
  • Standardized method based on extraction, filtration, and gas chromatography (GC) was developed far propylene glycol analysis to set hygienic norm of safety measure for foods under governmental control. Various columns were tested fur propylene glycol analysis by GC with flame ionization detector. Known amount of propylene glycol was spiked into wheat flour dough and analyzed by developed method. Results showed 101.60% recovery rate for propylene glycol with HP-5 column. Reproducibility test of standards recorded 0.30 for standard variation and 0,42% for relative variation. Using analytical method established, contents of propylene glycol in more than hundred different foods were monitored. Propylene glycol was detected in most foods, indicating propylene glycol is not only commonly added during food preparation, but also is contained naturally in food.

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

A Study on the Development of Long-term Self Powered Underground Pipeline Remote Monitoring System (자가 발전형 장기 지하매설배관 원격감시 장치 개발에 관한 연구)

  • Kim, Youngsear;Chae, Hyun-Byung;Seo, Jae-Soon;Chae, Soo-Kwon
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.576-585
    • /
    • 2018
  • Systematic management during the whole life cycle from construction to operation and maintenance is very important for the seven underground pipelines (waterworks, sewerage, electricity, telecommunications, gas, heating, oil including waterworks and sewerage). Especially, it is the construction process that affects the whole life cycle of underground buried pipeline. In order to construct a new city or to maintain different underground pipes, it is always necessary to dig the ground and carry out construction and related work. There is a possibility that secondary and tertiary breaks frequently occur in the pipeline construction process after the piping constructed first in this process. To solve this problem, a system is needed which can monitor damage in real time. However, the supply of electric power for continuous operation of the system is limited according to the environment of underground buried pipelines, so it is necessary to develop a stable electric power supply system using natural energy rather than existing electric power. In this study, we developed a system that can operate the pipeline monitoring system for long time (24 hours and 15 days) using natural energy using wind and solar light.

The Study about Role and Importance of Site Activity Stage in Safety Activity for the International Conference among Several Countries (다자간 국제회의 안전활동에 있어서 현장활동단계의 역할 및 중요성에 관한 연구 : 부산 APEC 행사를 중심으로)

  • Lee, Sun-Ki
    • Korean Security Journal
    • /
    • no.19
    • /
    • pp.105-138
    • /
    • 2009
  • This study's purpose is to present the improvement of effectiveness of security activity for international conference among Several Countries which can be held hereafter. On the basis of security activity problems originating in APEC that had been held in Busan in 2005. I made up questions three times to on the members of the police, military, fire figher and national intelligence service who had experienced in Busan APEC and recognition of possible problem and possibility of improvement on each item of questions was analyzed by Delphi Method. Also interviews with 4 security experts selected from each security agency were conducted to present improvement in each part of problem. The results obtained from the face to face interview with four experts of security-enforcement agency about the role and importance of site activity stage for international conference among several countries are as followings ; First, the system that experienced security-enforcement agents can be selected for the next national security event is needed, by data-basing the security-enforcement agents who were experienced in security event as man power management. Second, the middle-term plan for the introduction of high-tech equipment and joint inspection with relevant security agents are needed for the efficient explosive technical detection. Third, high-tech security equipment could be introduced through the international high-tech security equipment exhibition. Fourth, an anti-terrorism plan should be measured by sharing information through the cooperation with domestic and international intelligence agency. Fifth, public relations should be measured systematically by organization rather than agents' individual public relations. Sixth, political consideration to secure integrative coordination with other agency is needed for security activity, through normal cooperation with fire fighting related agency such as an electric, gas, elevator company. Seventh, a definite press guideline is needed for a convenient news coverage and safety during security event.

  • PDF

Performance Evaluation of Advance Warning System for Transporting Hazardous Materials (위험물 운송을 위한 조기경보시스뎀 성능평가)

  • Oh Sei-Chang;Cho Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.15-29
    • /
    • 2005
  • Truck Shipment Safety Information, which is a part of the development of NERIS is divided into Optimal Route Guidance System and Emergency Response System. This research is for establishing an advance warning system, which aims for preventing damages(fire, explosion, gas-escape etc.) and detecting incidents that are able to happen during transporting hazardous materials in advance through monitoring the position of moving vehicles and the state of hazardous materials in real-time. This research is peformed to confirm the practical possibility of application of the advance warning system that monitors whether the hazardous materials transport vehicles move the allowed routes, finds the time and the location of incidents of the vehicles promptly and develops the emergency system that is able to respond to the incidents as well by using the technologies of CPS, CDMA and CIS with testing the ability of performance. As the results of the test, communication accuracies are 99$\%$ in freeway, 96$\%$ in arterial, 97$\%$ in hilly sections, 99$\%$ in normal sections, 96$\%$ in local sections, 99$\%$ in urban sections and 98$\%$ in tunnels. According to those results, the system has been recorded a high success rate of communication that enough to apply to the real site. However, the weak point appeared through the testing is that the system has a limitation of communication that is caused in the rural areas and certain areas where are fewer antennas that make communication possible between on-board unit and management server. Consequently, for the practical use of this system, it is essential to develop the exclusive en-board unit for the vehicles and find the method that supplements the receiving limitation of the GPS coordinates inside tunnels. Additionally, this system can be used to regulate illegal acts automatically such as illegal negligence of hazardous materials. And the system can be applied to the study about an application scheme as a guideline for transporting hazardous materials because there is no certain management system and act of toxic substances in Korea.

  • PDF

Development of Economic Analysis Indicators and Case Scenario Analysis for Decision-making support for Off-Site Construction Utilization of Apartment Houses (OSC 활용 의사결정 지원을 위한 경제성 분석 지표 개발 및 사례 시나리오 분석 - 공동주택 PC공법을 중심으로 -)

  • Yun, Won-Gun;Bae, Byung-Yun;Shin, Eun-Young;Kang, Tai-Kyung
    • Korean Journal of Construction Engineering and Management
    • /
    • v.24 no.6
    • /
    • pp.24-35
    • /
    • 2023
  • Recently, the Ministry of Land, Infrastructure and Transport presented the '6th Construction Technology Promotion Basic Plan' and 'Smart Construction Revitalization Plan (2022.7.20)'. Off-Site Construction (OSC), which involves construction and production of PC (Precast Concrete) and Modular, etc., has advantages in shortening the construction period, reducing costs, improving quality, reducing construction waste, and reducing safety accidents. However, the construction cost is high compared to the traditional RC construction method, which has hindered its utilization and spread. In this study, OSC utilization was improved. An economic analysis indicator and methodology that can support decision-making in the planning and design stages for multi-unit housing were proposed. The factors used in the economic analysis of OSC (based on the PC method) of apartment houses were reviewed. As for the indicators used in the cost and benefit section, 'Construction Period', 'Disaster Occurrence', 'Waste Generation', and 'Greenhouse gas Emission', which reflect the technical advantages of OSC, were derived. In addition, a scenario analysis was conducted based on actual apartment housing case data for the presented economic analysis indicators and benefit calculation standards. The level of benefit that offsets the difference between the existing RC construction method and the construction cost was reviewed. In future studies, it will be necessary to conduct additional case studies to apply the measurement criteria for detailed indicators and supplement the benefit indicators.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • v.33 no.4
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Fatty acid analysis and regulatory effects of citron (Citrus junos Sieb. ex TANAKA) seed oil on nitric oxide production, lipid accumulation, and leptin secretion (유자씨유의 지방산분석 및 Nitric Oxide 생성, 지방축적능, 렙틴분비 조절효과)

  • Kim, Tae Woo;Kim, Kyoung Kon;Kang, Yun Hwan;Kim, Dae Jung;Choe, Myeon
    • Journal of Nutrition and Health
    • /
    • v.47 no.4
    • /
    • pp.221-228
    • /
    • 2014
  • Purpose: Citron seed oil (CSO) has been reported to have high antioxidant activity. However, the composition and other biologically activities of CSO have not been reported. In this study, we confirmed the fatty acid composition of CSO, which may be beneficial to vascular disease and obesity. Methods: We investigated the oil composition of CSO using gas chromatography coupled with mass spectrometry (GC-MS) analysis, and cytotoxicity was confirmed by Cell Counting Kit-8 (CCK-8) assay. Nitric oxide (NO) production in human umbilical vein endothelial cells (HUVECs) was measured using Griess reagent, and lipid accumulation and leptin secretion in 3T3-L1 cells were measured by Oil-Red O staining and commercial ELISA kit, respectively. Results: GC-MS analysis indicated that CSO contains several components, including linoleic acid, oleic acid, palmitic acid, stearic acid, linolenic acid, palmitoleic acid, and arachidic acid. In physiological activity analysis, CSO did not induce cytotoxic effects in HUVECs and 3T3-L1 cells. Further, CSO significantly induced nitric oxide and leptin secretion as well as inhibited lipid accumulation. Conclusion: CSO increased NO release, inhibited lipid accumulation, and induced leptin secretion, suggesting it may be useful for the management of vessels and weight gain. Although further studies are required to investigate the safety and mechanism of action of CSO, our results show that the composition and physiological activity of CSO are sufficient for its use as functional edible oil.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.