• Title/Summary/Keyword: Gas safety check

Search Result 55, Processing Time 0.028 seconds

Development of Check Angle Safety Valve for Residential Gas Piping (주택용 가스배관 체크앵글 안전밸브 개발 연구)

  • Lim, Sang Ho
    • Industry Promotion Research
    • /
    • v.2 no.1
    • /
    • pp.9-13
    • /
    • 2017
  • This study deals with the check valve safety valve for residential gas piping. It can be manually shut off within 1 second in case of emergency, and it is possible to touch 3kg of pressure by hand force. To develop the technology so that it can be used repeatedly. Study results after first valve operation. And 0.61 seconds on average. Therefore, it was found that there was no problem in operation even when used as a safety valve. Third, it was found that all of the results of using the blocking ball diameter of 7mm were not abnormal. In this study, it is meaningful to develop the check valve safety valve of gas piping and verify the performance by testing with existing valve.

Performance Test and System Analysis on Check-Floater in a Coil-Typed LP Gas Vaporizer (전열온수식 LPG 기화기 액 유출 방지장치 성능평가 및 시스템 분석)

  • Choi, Sung-Joon;Kwon, Jeong-Rock;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.46-50
    • /
    • 2007
  • The metering systems in LPG vaporizers have been frequently exposed to severe conditions and resulted in many problems such as gauge malfunctioning and rupturing if the check-floaters fail to stop liquid outflow when the heat supply for the vaporization of LPG is interrupted. Therefore, to analysis the vaporizer system we carried out the vaporizer performance test and float bulb test by newly devised test equipments. Consequently, we determined the specific gravity of the float bulb and reasonable operating temperature ranges for the LPG and heating waters.

  • PDF

Hydraulic Compressor Safety Test for Hydrogen Stations (수소충전소용 유압식 압축기 안전성 시험에 관한 연구)

  • Seong, Hye-Jin;Hwang, Bom-Chan;Choi, Sung-Joon;Kim, Young-Kyu;Cho, Sung-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.11
    • /
    • pp.8-15
    • /
    • 2020
  • The government has announced its Hydrogen Economy Roadmap to strengthen global competitiveness on the hydrogen economy by focusing on hydrogen fuel cell electric vehicles and fuel cells. In this regard, the interest on the economics and safety of the infrastructure of hydrogen stations has also increased. In this study, a test bed similar to an actual hydrogen charging facility was built, and a prototype of a piston-type compressor was modeled. In this model, the piston was hydraulically compressed to progressively test leakage, leakage rate, and durability and to check for any malfunction. Moreover, the leakage rate, cylinder leak performance, and compressor operation durability were evaluated for safety; it was confirmed that there were no abnormalities. Nevertheless, an investigation of the long-term use and operating pressure of the compressor is necessary to verify the safety of developing a100-MPa domestic compressor in the future.

A Study on Characteristics of Hydrogen Leakage in Hydrogen Town Governor Room (수소타운 정압기실 내 수소 누출 특성 연구)

  • NAM, TAE-HO;KIM, DONG-HWAN;LEE, JUNG-WOON;LEE, SEUNG-KUK;LEE, YEON-JAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.685-692
    • /
    • 2016
  • Hydrogen will be a future eco-friendly energy source that can replace current fossil fuels However when hydrogen gas leaks and people inhale a lot of hydrogen gases, they can have fatal effects fell into comas. Therefore, we need to develop a safety technology and related guidelines for reducing risks of hydrogen leakage. In this regard, we carried out demonstration tests assuming a situation of hydrogen leakage. Before the experiments, we analyze the standards for governor facilities to check vent positions and sensor positions. Then, we select four types of ventilation structures and proceeds with the experiments of hydrogen leakage at 1 LPM and 1.5 LPM. Based on the experimental results, we propose the direction on optimization of vent positions and sensor positions in the hydrogen leakage situation.

A Study on Durability Test of Check Valve for CNG Vehicles (천연가스 차량용 체크밸브의 내구성능에 관한 연구)

  • Kim, Chang-Gi;Lee, Sun-Youp;Cho, Gyu-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.6
    • /
    • pp.15-20
    • /
    • 2009
  • The number of compressed natural gas (CNG) vehicles have increased gradually by virtue of korea government's urban air quality improvement policy since 1998. Although the use of CNG as transportation fuel gives environmental benefits, there is a possibility of huge accidents from unexpected fire. Therefore, needs for the guarantee of safety are indispensible for the reliable operation of CNG vehicles. A check valve is a safety device which prevents leakage of the pressurized fuel charged in a fuel tank. Durability of this component should be guaranteed in spite of repeated operation. This research has performed durability tests of a CNG check valve regarding the repeated usage, extreme chattering, and the effect of compressor oil.Although a check valve used for CNG vehicle satisfies validation requirements in the test results, it has been found that problem in the function of leakage prevention in a check valve could take place in the case of prolonged exposure to compressor oil.

  • PDF

Study on Improvement of Safety Check System for Elevation Emergency Management Service (소방방재서비스 향상을 위한 안전점검 개선방안에 관한 연구)

  • Kong, Ha-Sung;Lee, Jeong-Il;Kim, Kook-Rae
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.42-57
    • /
    • 2006
  • This study suggests improvement plans : safety check system security through combination in stages, unification of fire inspection, enterprising security of prevention work, enforcement of certificate of qualification for safety, activation of civil partner-ship of fire disaster prevention through contrast prevention work of administrative service with civil mind and an in-depth analysis : dispersed and duplicated management current safety check service, improper commission collection, immorality diffusion of involved, potential irregularities causes, deficit of professionalism security.

A Study on development of repeat check system for product (제품 검사 시스템 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.3
    • /
    • pp.156-161
    • /
    • 2013
  • Gas valve time control system used to set the time to use the gas system by one of the user's negligence explosion, fire, and to prevent accidents such as suffocation. Gas valve is one of the items is not a replacement without any special issue after installation in each customer. So sufficient test is required prior to the installation device. In this study, the test system was developed to use to set the number of times at the gas valve time control system.

Suggestion for Safety Improvement of Compressed Natural Gas Vehicle (압축천연가스 자동차의 안전성 향상을 위한 제언)

  • Kim, Young-Seob;Park, Kyo-Shik;Kim, Tae-Ok
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2012
  • Systematic safety research by Korea Government has been made to enhance the safety of CNG (compressed natural gas) vehicles since the burst of compressed cylinder of an urban bus in August 9, 2010. This article summarizes some major activities to ensure the safety of CNG vehicles, which covers review of regulation, safety management system including standard of inspection and certification, and training program of inspectors and car mechanics. Specifically, the followings were reviewed; type of CNG cylinder, location of CNG cylinder, material and type of fuel line and vent line, modification of pipeline connection, installation of gas detector, installation of emergency shutdown valve, installation of protecting cover for cylinder, obligations for CNG vehicle filling station. improving periodical inspection, routine test on gas vehicles, training program for engaged in gas vehicles, and designation of safety manager for CNG bus company. This paper suggests how to improve safety of CNG vehicles as a result of review of above mentioned check items.

A Research on the Improvement & Actual Situation of Duplicated Safety Inspections for Facilities (시설별 안전점검 중복성에 대한 실태조사 및 개선방안 연구)

  • Park, Jongkeun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 2017
  • Safety inspection activities of the facilities including the electricity, gas, building, and firefighting, etc. are individual checks by the separate law of each government department, comprehensive inspections for the specific managed facilities or during a weak season, and national safety overall diagnostics for the disaster prevention. Thus, types of the inspections are various and they have been carried out repeatedly as well as duplicately. That can make the people or institutes to take such inspections feel great burdens. Therefore, the investigation on the current situation of the individual inspection by the separate law for the electricity, gas, building, and firefighting, etc. as well as of various others by the government needs to be carried out and according to the results the repetitive and duplicated inspections should be reduced and converged to one comprehensive one. In this regard, we proposed solutions to improve the government safety inspection system, function, and role.

A Study on the Improvement of Daily Inspection for the Safety of University Laboratory - Based on Delphi surney - (대학 연구실 안전을 위한 일상점검 개선방안에 관한 연구 - 델파이 조사를 기반으로 -)

  • Choi, Youn-Woo;Lee, yong-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.1
    • /
    • pp.38-48
    • /
    • 2019
  • The purpose of this study is to present a more effective daily checklist than the formal routine check before the experiment to prevent accidents in the university laboratory. To do this, we reconstructed the current daily checklist and previous research data and conducted a second Delphi survey. As a result, there were four general safeties such as arranging the laboratory, three mechanical safeties such as abnormal condition of machine and tool tightening parts, three electric safeties such as prohibition of loading around the electric distribution panel, six chemical safeties such as handling and managing harmful factors, three items of fire safety such as fire extinguisher inspection, five cases of gas safety gas container inspection, one item of biological safety such as the state of hand sterilizer management and one other item, which were provided in the daily checklist as twenty six categories in total. According to the opinions of related experts, it is necessary to have an easy and simplified daily checklist for actual daily checkups.