Performance Test and System Analysis on Check-Floater in a Coil-Typed LP Gas Vaporizer

전열온수식 LPG 기화기 액 유출 방지장치 성능평가 및 시스템 분석

  • Choi, Sung-Joon (Institute of Gas Safery R&D, Korea Gas Safety Corporation) ;
  • Kwon, Jeong-Rock (Institute of Gas Safery R&D, Korea Gas Safety Corporation) ;
  • Kim, Hyo (Dept. of Chemical Engineering, University of Seoul)
  • 최성준 (한국가스안전공사 가스안전연구원) ;
  • 권정락 (한국가스안전공사 가스안전연구원) ;
  • 김효 (서울시립대학교 화학공학과)
  • Published : 2007.03.31

Abstract

The metering systems in LPG vaporizers have been frequently exposed to severe conditions and resulted in many problems such as gauge malfunctioning and rupturing if the check-floaters fail to stop liquid outflow when the heat supply for the vaporization of LPG is interrupted. Therefore, to analysis the vaporizer system we carried out the vaporizer performance test and float bulb test by newly devised test equipments. Consequently, we determined the specific gravity of the float bulb and reasonable operating temperature ranges for the LPG and heating waters.

LPG저장설비나 용기에서 유입되는 LPG가 기화기로부터 충분한 열을 공급받지 못해 액체 상태로 기화기 출구를 통해 나가게 될 경우를 대비하여 설치한 액 유출 방지장치가 정상적으로 기화기 출구부를 차단하지 못하면 기화기 후단부에 설치한 계량기등이 LPG의 순간적인 부피팽창으로 인하여 고장나거나 파열하게 된다. 따라서 이와 같은 기화기 관련 사고를 분석하기 위하여 새롭게 개발한 투명기화통을 이용하여 기화기의 성능평가 및 액유출 방지장치를 분석하였다. 이로부터 액 유출 방지장치 플로트 밸브의 적절한 비중값과 자연대류만으로 열전달을 수행하는 LPG 기화기에 적합한 온도조절 범위를 결정하였다.

Keywords