• 제목/요약/키워드: Gas generate

검색결과 348건 처리시간 0.037초

천연가스 조성에 따른 수소 생산 시에 발생하는 이산화탄소 배출량 산출에 대한 연구 (A Study on the Estimation of Carbon Dioxide Generation During High Purity Hydrogen Production According to Natural Gas Composition)

  • 조정호;노재현;김동선
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.485-489
    • /
    • 2019
  • Hydrogen is known to be a clean fuel which does not generate a green house gas during the combustion. However, about 8 kg of carbon dioxide is generated during the course of producing 1 kg of hydrogen through reforming, water gas shift reaction and pressure swing adsorption in order to obtain a high purity hydrogen over 99.999% by volume. In this work, carbon dioxide generation is estimated according to four kinds of natural gas compositions supplied by Korea Gas Corporation and regarding natural gas as pure methane. For the simulation of the modeling, PRO/II with PROVISION V10.2 at AVEVA was utilized and Peng-Robinson equation of state with Twu's alpha function was selected.

가솔린 엔진개조 CNG 발전기 개발과 동급 디젤엔진의 배출가스 특성 연구 (Development of Gasoline Engine Renewal CNG Generator and a Study on Exhaust Gas Characteristics of Equivalent Diesel Engine)

  • 이정천;김기호;이정민;박언영
    • 동력기계공학회지
    • /
    • 제22권6호
    • /
    • pp.74-79
    • /
    • 2018
  • Compressed natural gas has a high octane number and low particulate emission characteristics as compared with petroleum-based fuels, so it can respond to exhaust gas regulations positively. A natural gas engine has been introduced to improve the quality of the atmosphere, a diversity of fuel, a stable supply, and it has widely been used in city buses and garbage trucks. Recently, the natural gas engine has received attention by overcoming the disadvantage of the theoretical air-fuel ratio method through the development of EGR cooler and engine parts with the development of LP-EGR technology. In this study, we try to develop the cogeneration system that can simultaneously generate electric power and heat by remodeling the gasoline engine to the mixer type CNG engine. As a result, it was able to reduce the NOx (approximately 77%) compared to the diesel engines with same displacement.

보일러 사용 패턴에 따른 누출점검용 가스계량기 누출 알람 신뢰도 개선 연구 (A Study on the Improvement of Leak Alarm Reliability of Gas Meter for Leak Inspection according to Boiler Usage Pattern)

  • 양진두;이승원;최은일;임성현
    • 한국가스학회지
    • /
    • 제27권3호
    • /
    • pp.72-76
    • /
    • 2023
  • 도시가스 사용시설 중 은폐배관에 점검구를 대신하여 누출점검용 가스계량기를 사용하는 사례가 증가하고 있다. 이 계량기가 설치되어 있는 일부 세대 중 실제 가스누출이 없는 환경에서 보일러의 특수한 사용 패턴에 따라 누출 알람 경보가 지속적으로 발생되었다. 실제 가스 누출을 감지하는 본연의 기능을 발휘하지 못하는 실정이다. 이러한 문제점에 착안하여 본 연구에서는 보일러의 특수한 가스 사용 패턴에 따라 누출점검용 가스 계량기가 누출 알람을 발생시키는 조건을 분석하고, 실제 가스 누출이 있는 경우에만 계량기에서 알람을 발생 할 수 있는 설정값을 모색해 보았다. 이를 통해 알람의 오작동으로 인한 시민의 가스 사용에 대한 불안감을 해소함과 동시에 누출되고 있는 가스를 포착할 수 있는 계량기 본연의 기능을 수행할 수 있도록 하고자 한다.

100 kW급 용융탄산염 연료전지 시스템 개발 II(스택 및 시스템 설계) (System Development of a 100 kW Molten Carbonate Fuel Cell II (Design of Stack and System))

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1322-1324
    • /
    • 2002
  • For developing a 100 kW MCFC power generation system, Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately 170 cells are required to generate 100 kW at a current density of 125 mA/$cm^2$ with 6000 $cm^2$ cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at 125 mA/$cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. Also system efficiency was calculated at various type of system and operation conditions.

  • PDF

천연가스를 이용한 자열개질기의 운영조건에 대한 수치해석 연구 (Numerical Study on operating conditions of Autothermal Reformer using natural gas)

  • 김진욱;김상우;박달영;전상희;이도형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.91.1-91.1
    • /
    • 2010
  • The Reforming system is an effective method to generate hydrogen which uses for fuel cell system. The purpose of this study is to present characteristics of an autothermal reformer at various operating conditions and to investigate ideal conditions for reforming efficiency. Dominant chemical reactions are Full Combustion, Steam Reforming reaction, Water-Gas Shift reaction and Direct Steam Reforming reaction. Operating parameters of the autothermal reformer are inlet temperature, Oxygen to Carbon Ratio, Steam to Carbon Ratio and Gas Hourly Space Velocity. Autothermal reformer is filled with catalysis of a packbed-bed type. Using numerical approach, we have investigated on various reaction conditions.

  • PDF

Performance Evaluation of Gas Cleaning Industrial Filters using a Bi-Modal Test Aerosol for Dust Loading Studies

  • Lee, Jae-Keun;Kim, Seong-Chan;Benjamin Y.H. Liu
    • 에너지공학
    • /
    • 제5권2호
    • /
    • pp.131-137
    • /
    • 1996
  • Typical size distribution of emission particulates is bi-modal in shape with particles in the fine mode (< 2.0 $\mu\textrm{m}$) and the coarse mode. An experimental study of pressure drop across the industrial gas cleaning filters has been conducted using particle mixture of fine alumina and coarse Arizona dusts with a rotating aerosol disperser to generate the bi-modal test aerosol. Pressure drop increased linearly with increasing mass loading. The pressure drop was found to be strongly dependent upon the mass ratio of fine to coarse particles. The smaller the mass ratio of fine to coarse particles and the higher face velocity are, the faster pressure drop rises. The fine particles and the greater inertia of the particle moving fast would cause a denser cake formation on the filter surface, resulting in a greater specific resistance to the gas flow.

  • PDF

LPG 인젝터형 플라즈마 개질기 적용연구 (Application Research on LPG Injector type Plasma Reformer)

  • 김창업;이대훈
    • 한국가스학회지
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 2014
  • 본 연구에서는 LPG자동차용 LPG 액상분사 인젝터의 분사구 앞에 장착할 수 있는 플라즈마 개질기의 개발을 진행하였다. 이 개질기는 플라즈마 방전이 발생하는 영역에 공기와 LPG 연료를 분사시켜 고분자 탄소연료를 열해리시키고 추가로 수소를 발생시키기 위한 목적으로 개발되었다. 인젝터와 플라즈마 발생부와의 거리와 기하학적인 방전길을 최적화하여 개질 반응이 일어나는 인젝터 개질기를 완성하였으며, 개질 결과 공급 전력 70~100W 일 때 HC은 전체 개질가스의 약 0.7% 이며, 수소는 1.2~1.5% 발생하였다.

전과정을 고려한 에너지 자원별 전력생산의 온실가스 배출량과 비용의 상관관계 분석 (Life cycle analysis on correlation relationship between GHG emission and cost of electricity generation system for energy resources)

  • 김희태;안태규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.136.2-136.2
    • /
    • 2011
  • In this work, we analyzed correlations between life-cycle greenhouse gas (GHG) emissions and life-cycle cost of energy resources. Energy resources studied in this paper include coal, natural gas, nuclear power, hydropower, geothermal energy, wind power, solar thermal energy, and solar photovoltaic energy, and all of them are used to generate electricity. We calculated the mean values, ranges of maximum minus minimum values, and ranges of 90% confidence interval of life-cycle GHG emissions and life-cycle cost of each energy resource. Based on the values, we plotted them in two dimensional graphs to analyze a relationship and characteristics between GHG emissions and cost. Besides, to analyze the technical maturity, the GHG emissions and the range of minimum and maximum values were compared to each other. For the electric generation, energy resources are largely inverse proportional to the GHG emission and the corresponding cost.

  • PDF

100 kW급 용융탄산염 연료전지 시스템 개발 I (시스템 및 스택 설계) (System Development of a 100 kW Molten Carbonate Fuel Cell I (Design concept of Stack and System))

  • 임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1300-1302
    • /
    • 2001
  • For developing a 100 kW MCFC power generation system. Several design parameters for a fuel cell stack and system analysis results by Cycle Tempo, a processing computer soft ware, were described. Approximately 170 cells are required to generate 100 kW at a current density of $125mA/cm^2$ with $6000cm^2$ cells. An overall heat balance was calculated to predict exit temperature. The 100 kW power is expected only under pressurized operation condition at 3 atm. Recycle of cathode gas by more than 50% is recommended to run the stack at $125mA/cm^2$ and 3 atm. Manifolds should be designed based on gas flow rates for the suggested operating condition. The fuel cell power generation system was designed conceptually with several choices of utilization of anode exhaust gas. Also system efficiency was calculated at various type of system and operation conditions.

  • PDF

연도가스 열회수용 순환유동층 열교환기의 오염저감특성 (Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery)

  • 이금배;전용두
    • 설비공학논문집
    • /
    • 제16권8호
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.