• Title/Summary/Keyword: Gas detector

Search Result 577, Processing Time 0.038 seconds

Monitoring of Benzoic, Sorbic and Propionic Acid in Cereal Grains, Nuts and Seeds (곡류 및 견과 종실류 중 안식향산, 소브산, 프로피온산의 함유량 조사)

  • Yun, Sang Soon;Lee, Sang Jin;Lim, Do Yeon;Lim, Ho Soo;Lee, Gunyoung;Kim, MeeKyung
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • This study was aimed at investigating the levels of the natural preservatives of benzoic, sorbic and propionic acids in cereal grains, nuts and seeds. Benzoic and sorbic acid were analyzed by high-performance liquid chromatography with a diode-array detector (HPLC-DAD) and further confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), whereas propionic acid was analyzed using a gas chromatography-flame ionization detector (GC-FID) and further confirmed by gas chromatography-mass spectrometry (GC-MS). Benzoic, sorbic and propionic acids were found in 44, 22, and 550 samples out of 702 samples, respectively. From the total of 702 samples. The concentrations of benzoic, sorbic and propionic acid were ranged from not detected (ND) to 23.74 mg/L, from ND to 7.90 mg/L, and from ND to 37.39 mg/L in cereal grains, nuts and seeds, respectively. The concentration ranges determined in this study could be used as standard criteria in the process of inspecting cereal grains, nuts and seeds for preservatives as well as to address consumer complaints or trade disputes.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Analysis of Trans Fatty Acid Content in Processed Foods and Meat Products (가공식품과 육가공품의 트랜스 지방산 함량 조사)

  • Park, Jung-Min;Ji, Won-Gu;Kim, Eun-Jung;Park, Da-Jung;Shin, Jin-Ho;Shim, Soon-Mi;Suh, Hyung-Joo;Chang, Un-Jae;Kang, Duk-Ho;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.27 no.4
    • /
    • pp.531-537
    • /
    • 2007
  • Small amounts of trans fatty acids exist naturally in beef and dairy foods. Also, they can be produced in the process of partial hydrogenation to manufacture shortning or margarine. They can provide a better palatability and shelf life. According to the recently studies, trans fatty acids can raise health risk such as heart diseases and coronary artery diseases. They can also increase low-density lipoprotein (LDL) cholesterol and decrease high-density lipoprotein (HDL) cholesterol in the blood plasma, therefore increasing the risk of atherosclerosis and diabetes. The aim of this study was to determine total lipids and trans fatty acids (TFAs) content in processed foods and meat products. The analysis of trans fatty acids was performed in 28 samples of donuts, 18 samples of bakeries, 4 samples of frozen doughs, 2 samples of popcorns, and 4 samples of meat products (ham, sausage, nuget, and bacon). Total lipids in processed foods and meat products were extracted by chloroform-Methanol method and acid digestion, respectively. They were analyzed by gas chromatography using a SP-2560 column and flame ionization detector. The amounts of TFAs per 100 g of foods were 0-3.3% (0.74% on average) in donuts, 0.2-5.8% (1.18% on average) in bakeries, 0.2-6.3% (1.93% on average) in frozen doughs, and 0-5.8% in popcorns. Meat products such as ham, sausage, and nuget analyzed 0.1% of TFAs, respectively and trans fatty acids in bacon were not detected. As a result, the distribution of TFAs in processed foods was widely ranged from O% to 6.3% according to manufacturers and types of products, whereas the content of TFAs in meat products ranged from 0% to 0.1%.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Biological Monitoring of Paint Handling Workers exposed to PAHs using Urinary 1-Hydroxypyrene (다핵방향족탄화수소류에 노출된 페인트 취급 근로자에서 요 중 1- Hydroxypyrene을 이용한 생물학적 모니터링)

  • Lee, Jong-Seong;Kim, Eun-A;Lee, Yong-Hag;Moon, Deog-Hwan;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.124-134
    • /
    • 2005
  • To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.

The development of conductive 10B thin film for neutron monitoring (중성자 모니터링을 위한 전도성 10B 박막 개발)

  • Lim, Chang Hwy;Kim, Jongyul;Lee, Suhyun;Jung, Yongju;Choi, Young-Hyun;Baek, Cheol-Ha;Moon, Myung-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.199-205
    • /
    • 2014
  • In the field of neutron detections, $^3He$ gas, the so-called "the gold standard," is the most widely used material for neutron detections because of its high efficiency in neutron capturing. However, from variable causes since early 2009, $^3He$ is being depleted, which has maintained an upward pressure on its cost. For this reason, the demands for $^3He$ replacements are rising sharply. Research into neutron converting materials, which has not been used well due to a neutron detection efficiency lower than the efficiency of $^3He$, although it can be chosen for use in a neutron detector, has been highlighted again. $^{10}B$, which is one of the $^3He$ replacements, such as $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$, is being researched by various detector development groups owing to a number of advantages such as easy gamma-ray discrimination, non-toxicity, low cost, etc. One of the possible techniques for the detection is an indirect neutron detection method measuring secondary radiation generated by interactions between neutrons and $^{10}B$. Because of the mean free path of alpha particle from interactions that are very short in a solid material, the thickness of $^{10}B$ should be thin. Therefore, to increase the neutron detection efficiency, it is important to make a $^{10}B$ thin film. In this study, we fabricated a $^{10}B$ thin film that is about 60 um in thickness for neutron detection using well-known technology for the manufacturing of a thin electrode for use in lithium ion batteries. In addition, by performing simple physical tests on the conductivity, dispersion, adhesion, and flexibility, we confirmed that the physical characteristics of the fabricated $^{10}B$ thin film are good. Using the fabricated $^{10}B$ thin film, we made a proportional counter for neutron monitoring and measured the neutron pulse height spectrum at a neutron facility at KAERI. Furthermore, we calculated using the Monte Carlo simulation the change of neutron detection efficiency according to the number of thin film layers. In conclusion, we suggest a fabrication method of a $^{10}B$ thin film using the technology used in making a thin electrode of lithium ion batteries and made the $^{10}B$ thin film for neutron detection using suggested method.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Monitoring of Polycyclic Aromatic Hydrocarbons in Sediments and Organisms from Korean Coast

  • Moon Hyo-Bang;Choi Hee-Gu;Kim Sang-Soo;Jeong Seung-Ryul;Lee Pil-Yong;Ok Gon
    • Fisheries and Aquatic Sciences
    • /
    • v.4 no.4
    • /
    • pp.219-228
    • /
    • 2001
  • Surface sediments (0- 5 cm), mussels (Mytilus coruscus and M. edulis) and oysters (Crassostrea gigas) were sampled at 20 stations in Korean coast during a period of February to July 2000. Samples were analyzed for polycyclic aromatic hydrocarbons (PAHs) content using gas chromatography coupled to mass spectrometer detector (GC/MSD). The sediment $\sum PAH$ concentration varied from 7 to 1,214 ng/g dry weight and the level of carcinogenic PAHs of six species ranged from 1 to 563 ng/g dry weight in surface sediments. In organisms, the levels of $\sum PAH$ were in the range of 63-876 ng/g dry weight and the concentrations of carcinogenic PAHs of six species were in the range of 4-582 ng/g dry weight. The highest PAH concentrations in sediments and organisms were in samples from Station 5 in Pohang coast and Station 8 in Jinhae coast, respectively. $\sum PAH$ concentrations in sediments and organisms collected from Korean coast were slightly low or comparable to those in other countries. The contribution of ring aromatic groups to sum of 16 PAHs in sediments and organisms showed a similar pattern for most stations. In sediments, the predominant contributions were four and five ring aromatics like fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene and benzo[a]pyrene. In the organisms, four ring aromatics like fluoranthene, pyrene, benzo[a]anthracene and chrysene were predominant PAH species. Several molecular indices such as phenanthrene/anthracene, fluoranthene/pyrene and LMW/HMW ratio were used to identify the origin of PAH contamination in sediments. The results indicate that PAHs of Korean coast were mainly of pyro1ytic contaminants with slight petrogenic input. A high correlation within individual PAH compound in marine sediments was observed, while correlation in organisms showed a highly significant relationship for heavier molecular weight PAHs.

  • PDF

Analysis of Butyltin Compounds(mono-, di-, and tributyltin) in Human Blood (혈액 중의 주석화합물(MBT, DBT, TBT)의 분석과 농도에 관한 연구)

  • Kim, Nam Sook;Park, Dong Uk;Oh, Jae Ryoung;Shim, Woon Joon
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.115-122
    • /
    • 2001
  • Butyltin compounds, including mono-(MBT), di-(DBT) and tributyltin(TBT) were analyzed in 44 human blood samples randomly collected from a hospital in "K" a city. Gas chromatograph equipped with flame photometric detector(FPD) was used to quantify the amounts of butylin compounds. Method detection limits(MDL) of this analytical method were 3.69ng Sn/g for MBT, 0.91ng Sn/g for DBT and 1.09ng Sn/g wet wt for TBT respectively. Standard reference material(SRM) containing of $1.3{\mu}g/g$ TBT as chloride was analyzed to check if this analytical results would be reliable. Recovery of about 90% was obtained through this analysis, indicating that the analytical method from butyltin compounds blood was reliable. The concentrations of butyltin compounds ranged MDL(<3.69) to 7.93ng Sn/g for MBT and 1.15 to 5.41ng Sn/g wet wt for DBT. Tributyltin was below detection limit in all samples. Detection limits of our results are lower than those reported by Kannan et al. who reported butyltin compounds in 33 human blood samples in the United States. Detection of MBT and DBT on blood sample implies that butyltin compounds could be absorbed through consumption of seafoods or exposure to food stuffs made of plastics and household items. Further study is needed to examine if butyltin compounds in blood can be reliably analyzed and used as intake index.

  • PDF

Determination of Gross-${\beta}$ and ${\gamma}$-Ray Activity Concentrations of Human Tooth (치아의 전베타 농도 및 감마선 방사능 평가)

  • Jeong, Hyunja;Kang, Hyun-Kyung;Kim, Sunghwan
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.261-265
    • /
    • 2014
  • The ${\gamma}$-ray concentration and gross-${\beta}$ activity by age group were measured in the teeth of males and females of the domestic residents. They were divided into 7 age groups from 10s to the age of 70s. The gross-${\beta}$ activity concentration was measured by using the Tennelec XLB measuring instrument filled with P10 gas (argon 90%, methane 10%). The ${\gamma}$-ray was measured through the ${\gamma}$-ray spectroscopic analytical method by using the high purity germanium (HPGe) radiation detector. The range of gross-${\beta}$ activity concentration was measured 0.089 to 0.32 Bq/kg in females and 0.13 to 0.26 Bq/kg in males. From the ${\gamma}$-ray spectroscopic analysis of the teeth, the natural radioactive isotopes of $^{40}K$, $^{208}Tl$, $^{228}Ac$ and $^{234}Th$ were detected and their measured ${\gamma}$-ray activity concentrations were found to be 20.7, 21.9, 3.88 and 5.24 Bq/kg, respectively.