• 제목/요약/키워드: Gas control valve

검색결과 248건 처리시간 0.024초

DME를 착화촉진제로 사용한 가솔린 예혼합 압축 착화 엔진의 연소 특성 (Combustion Characteristics of Gasoline HCCI Engine with DME as an Ignition Promoter)

  • 염기태;장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.178-185
    • /
    • 2006
  • This paper investigates the steady-state combustion characteristics of the Homogeneous charge compression ignition(HCCI) engine with variable valve timing(VVT) and dimethyl ether(DME) direct injection, to find out its benefits in exhaust gas emissions. HCCI combustion is an attractive way to lower carbon dioxide($CO_2$), nitrogen oxides(NOx) emission and to allow higher fuel conversion efficiency. However, HCCI engine has inherent problem of narrow operating range at high load due to high in-cylinder peak pressure and consequent noise. To overcome this problem, the control of combustion start and heat release rate is required. It is difficult to control the start of combustion because HCCI combustion phase is closely linked to chemical reaction during a compression stroke. The combination of VVT and DME direct injection was chosen as the most promising strategy to control the HCCI combustion phase in this study. Regular gasoline was injected at intake port as main fuel, while small amount of DME was also injected directly into the cylinder as an ignition promoter for the control of ignition timing. Different intake valve timings were tested for combustion phase control. Regular gasoline was tested for HCCI operation and emission characteristics with various engine conditions. With HCCI operation, ignition delay and rapid burning angle were successfully controlled by the amount of internal EGR that was determined with VVT. For best IMEP and low HC emission, DME should be injected during early compression stroke. IMEP was mainly affected by the DME injection timing, and quantities of fuel DME and gasoline. HC emission was mainly affected by both the amount of gasoline and the DME injection timing. NOx emission was lower than conventional SI engine at gasoline lean region. However, NOx emission was similar to that in the conventional SI engine at gasoline rich region. CO emission was affected by the amount of gasoline and DME.

비례유량제어밸브 위치제어기 자동조정 (Auto Tuning of Position Controller for Proportional Flow Control Solenoid Valve)

  • 정규홍
    • 대한기계학회논문집A
    • /
    • 제36권7호
    • /
    • pp.797-803
    • /
    • 2012
  • 비례솔레노이드밸브는 코일전류에 비례하는 전자기력을 이용하여 밸브 변위를 연속적으로 가변시키는 밸브이다. 대용량 비례유량제어밸브는 발전소나 화학 플랜트에서 물, 스팀, 가스 등과 같은 공정유체의 대용량 유량제어에 사용되며 공압이나 모터를 이용하는 밸브에 비하여 우수한 응답성능과 소형화의 장점을 가진다. 본 연구에서는 비례제어밸브를 대상으로 밸브의 동적 특성을 식별한 후 목표 성능이 만족되도록 위치제어기의 비례적분이득을 자동으로 조정하는 기능을 설계하였다. 동특성 식별은 릴레이 피드백을 통하여 한계 안정 상태에서의 임계이득과 임계주기로 파악하였으며, 비례적분이득 결정에는 Ziegler-Nichols 방법을 적용하였다. 구현된 기능은 시험을 통하여 성능을 검증하였으며 밸브 작동점과 릴레이 제어기 변수가 자동조정에 미치는 영향을 분석하였다.

스마트 폰 기반 홈 자동제어시스템 설계 및 구현 (A Home Automation system based on Smart phone)

  • 장용재;박경욱;이성근
    • 한국전자통신학회논문지
    • /
    • 제6권4호
    • /
    • pp.589-594
    • /
    • 2011
  • 스마트 폰 또는 홈 네트워크 기술은 지속적으로 부가가치를 창출할 수 있는 기술로, 삶의 질을 한층 더 높게 만들어 준다. 본 논문에서는 스마트 폰을 통해 스마트 홈을 제어 하는 시스템을 설계 및 구현하였다. 구현된 스마트 홈 시스템은 홈 노드 구조물, 원격 스마트 응용 시스템, 홈 서버 제어 시스템으로 구성된다. 홈 노드 구조물은 침입 감지, 가스 검출 및 밸브 제어, 도어 락, 자동커튼, 환풍기 제어 및 On/Off 제어 모듈로 구성되어 있으며 모듈들은 홈 서버에 의해서 제어 된다. 홈 서버는 사용자가 직접 제어할 수 있는 사용자 인터페이스와 스마트 폰을 이용하여 원격 제어할 수 있는 원격 인터페이스를 제공함으로써 언제 어디서나 편리하게 홈 자동제어시스템을 제어할 수 있다.

Development of partial liquefaction system for liquefied natural gas carrier application using exergy analysis

  • Choi, Jungho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제10권5호
    • /
    • pp.609-616
    • /
    • 2018
  • The cargo handling system, which is composed of a fuel gas supply unit and cargo tank pressure control unit, is the second largest power consumer in a Liquefied Natural Gas (LNG) carrier. Because of recent enhancements in ship efficiency, the surplus boil-off gas that remains after supplying fuel gas for ship propulsion must be reliquefied or burned to regulate the cargo tank pressure. A full or partial liquefaction process can be applied to return the surplus gas to the cargo tank. The purpose of this study is to review the current partial liquefaction process for LNG carriers and develop new processes for reducing power consumption using exergy analysis. The developed partial liquefaction process was also compared with the full liquefaction process applicable to a LNG carrier with a varying boil-off gas composition and varying liquefaction amounts. An exergy analysis showed that the Joule-Thomson valve is the key component needed for improvements to the system, and that the proposed system showed an 8% enhancement relative to the current prevailing system. A comparison of the study results with a partial/full liquefaction process showed that power consumption is strongly affected by the returned liquefied amount.

자동차용 기관의 냉각수 온도조절 최적화에 관한 연구(I) (A Study on the Optimum Cooling Water Temperature Control of an Automotive Engine(I))

  • 박경석;신진식;이경우
    • 오토저널
    • /
    • 제14권2호
    • /
    • pp.34-43
    • /
    • 1992
  • The purpose of this study is to consider the performance and exhaust characteristics in the practical engine according to the cooling water temperature change of engine and to set up the optimum cooling condition and to obtain the optimum operating condition of thermostat in the cooling system. In order to accomplish the purpose of this study, authors have used the following procedure. 1. This study is to investigate the influence of the cooling water temperature on the engine performance and the exhaust gas, authors regulated the cooling water temperature by using the special closing circuit and measured the concentration of exhaust gas by using the exhaust gas measuring system in the exhaust pipe. 2. This study carried out the experiment by regulating the opening degree of throttle valve and engine speed in the dynamometer and by changing the cooling water temperature, at the same time kept air-fuel ratio constant and made the spark ignition time MBT(Minimum spark advance for Best Torque) 3. This study measured the cooling water temperature by using the K-type thermocouple centring around the easy over-heated parts and by installing a special closing circuit. Therefore, in this study, authors intend to examine the influence of the cooling water temperature on the engine performance, exhaust gas and present the basic materials needed in the engine design including the optimum operating time control system for the cooling water temperature.

  • PDF

HAZOP을 통한 해양플랜트 흡착식 탈수공정 패키지의 위험성평가 및 안전도 향상 방안 (A Case Study on the Risk Assessment for Offshore Plant Solid Desiccant Dehydration Package by using HAZOP)

  • 노현정;박상현;조수길;강관구;김형우
    • 한국산업융합학회 논문집
    • /
    • 제23권4_2호
    • /
    • pp.569-581
    • /
    • 2020
  • Since the dehydration packages of offshore plant deal directly with oil & gas, there is a great risk of fire and explosion during operation. Therefore, this study performed risk assessment through HAZard & OPerability (HAZOP) for solid desiccant dehydration package that can remove water component of natural gas in offshore floating liquefied natural gas (LNG) production facilities below 0.1 ppmv. The risk matrix was determined by dividing the likelihood and the severity into five levels separately by asset, life, environment and reputation. The piping & instrumentation diagram (P&ID) of the dehydration package was divided into 9 nodes. Total 22 deviations were assessed in consideration of the adsorption and desorption conversion cycle. A risk assessment based on deviations revealed 14 major hazards. Three representative types of hazards were open/close failure of the control valve, control failure of the heater, and abnormal operation of the regeneration gas cooler. Finally, we proposed the installation of additional safety devices to improve safety against these major hazards, such as safety instrumented functions, alarms, etc.

KSLV-I RCS 추력기 개발 및 수행 평가에 대한 연구 (Research on Development and Performance Evaluation for Thruster of Reaction Control System for KSLV-I)

  • 전상운;정슬
    • 전자공학회논문지SC
    • /
    • 제47권3호
    • /
    • pp.19-27
    • /
    • 2010
  • KSLV-I은 100kg급 소형 인공위성을 지구 저궤도에 진입시키는 임무를 수행하여야 하며, 이를 위해 상단의 3축 자세제어를 위한 자세제어 시스템이 요구된다. 추력기 노즐을 통해 질소가스를 방출함으로써 발생하는 작용 반작용 모멘트를 제어모멘트로 사용하는 냉가스 추력기 자세제어 시스템을 KSLV-I 상단의 3축 자세제어 시스템으로 선정하였다. 본 논문에서는 KSLV-IRCS 추력기의 설계 및 기능시험, 성능시험, 환경시험에 대한 내용을 다룬다.

세라믹 압전체에 부착된 판 스프링의 유한요소해석과 질량 흐름 제어에 관한 연구 (A Study on Mass Flow Control and FEA of Plate Spring Attached in Piezoelectric Ceramic)

  • 이상경;김영수
    • 동력기계공학회지
    • /
    • 제7권4호
    • /
    • pp.61-66
    • /
    • 2003
  • In this paper, the relation between displacement of piezoelectric material and electric field was proposed. FEA was introduced to predict the displacement and reaction force of plate spring attached in the piezoelectric material. The relation between displacement of piezoelectric material forced by plate spring and applied electric field were further verified by experimental investigation. Also, the flow rate of gas in piezoelectric valve was examined by experiment. Finally, the relation between electric field and gas flow was derived. Based on these results, these relations can be used in the design of mass flow controller.

  • PDF

5MW급 발전용 가스터빈 엔진의 작동 특성 (Operating Characteristics of 5MW Class Gas Turbine Engine for Power Generation)

  • 박준철;홍성진;;류제욱
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.331-334
    • /
    • 2010
  • 두산중공업(주)에서 개발 중인 발전용 가스터빈 DGT-5 엔진의 작동 특성을 평가하였다. 다양한 연료 스케쥴과 여러 가지 조합의 bleed valve 개폐 제어에 대한 영향을 분석하기 위한 시험을 통해 시동 특성을 개선하였고, 시동부터 부하운전 전체 작동 영역에서 압축기에서의 불안정 현상 없이 엔진이 안정적으로 작동됨을 확인하였다. 순간적인 부하 변동과 load rejection에 대한 엔진의 동적 거동 분석을 통해 실제 계통 병입 조건에서 급격한 부하변동 시 엔진이 안정적으로 제어될 수 있음을 확인하였다.

  • PDF

플레어 시스템의 최적 운영방안에 대한 연구 (A Study on Optimal Operation for Flare systems)

  • 송방언;복형준;우인성
    • 한국가스학회지
    • /
    • 제23권6호
    • /
    • pp.1-7
    • /
    • 2019
  • 대부분의 정유 및 화학 시설에는 정전 등 갑작스러운 공정 정지 등의 문제로 인한 다량의 가스를 방출해야 하는 비상상황 발생에 대비하여 공정시설의 압력 상승을 완화하기 위해 설계된 플레어 시스템을 가지고 있다. 하지만 플레어 시스템의 불꽃 상승은 가시적 공해로 인한 공장 주변 주민들의 민원을 유발하며, 회사에서는 경제적 손실이 발생하므로 이에 대한 상시 관리가 필요한 상황이다. 본 연구에서는 플레어 시스템의 최적 운영방안을 도출하기 위하여 두 가지 항목에 대해 진단 및 분석을 진행하였다. 첫째, 불꽃 높이 상승 원인을 확인하기 위해 음향누출 측정기를 이용하여 안전밸브 및 압력 조정 밸브에서의 가스 누설을 탐지하였다. 둘째, 불꽃 불안전성 원인 파악을 위해 밀봉 드럼에 대해 CFD 모사 및 모형 제작실험을 통한 맥동 현상 발생을 진단하였으며 밀봉 드럼은 정상이며, 안전밸브의 4.3% 및 압력 조정 밸브의 10%에서 누설을 확인함으로써 비정상적인 불꽃 발생의 원인을 도출하였다. 본 연구결과에서 제시되는 사항은 플레어 시스템을 보유한 모든 회사에 적용이 가능하므로 이를 통한 민원 발생 및 제품손실의 방지가 기대된다.