• Title/Summary/Keyword: Gas concentration

Search Result 4,119, Processing Time 0.034 seconds

Flame Extinguishing Concentrations and Flue Gas Compositions of n-Heptane by Mixed Inert Gas Agents (불활성 가스계 혼합소화약제의 n-Heptane 불꽃소화농도 및 배가스 조성)

  • 김재덕;김영래;홍승태;이성철
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.77-83
    • /
    • 2002
  • We measured flame extinguishing concentration and flue gas composition in the n-heptane fuel cup-burner system using inert gas agents such as nitrogen, argon, carbon dioxide and their mixtures. The flame extinguishing concentration of binary gaseous mixture was well predicted by model which contains the flame extinguishing concentration and composition of pure components. The higher average specific gravity of the mixed inert gas agents, the more excellent flame extinguishing performance. And the structure of enclosed space also affects the fire extinguishing. The composition of carbon dioxide in the flue gas was decreased with increasing extinguishing agent used. Nitrogen monoxide production is not related with increasing nitrogen, but increased at rapid mass flow rate of air in the cup-burner.

Formation of particulate-phase and gas-phase polycyclic aromatic hydrocarbons in cigarette smoke

  • Shimazu, Haruki;Yata, Tsuyoshi;Ozaki, Naoto
    • Advances in environmental research
    • /
    • v.6 no.3
    • /
    • pp.189-202
    • /
    • 2017
  • This study examines the concentrations of particulate-phase polycyclic aromatic hydrocarbons (PAHs) and gas-phase PAHs in sidestream cigarette smoke. Sixteen PAHs were determined for four brands of cigarettes. The volume of the experimental room is approximately $66m^3$. The air samples in the room were collected before and after smoking. The median total of particulate-phase and gas-phase PAH concentrations before smoking $3.13ng/m^3$and $48.0ng/m^3$, respectively. The median concentrations of them after smoking were $10.0ng/m^3$ and $79.6ng/m^3$. The median increases in the total of 16 PAH concentrations per cigarette during smoking were 271 ng for the particulate-phase PAHs and 1960 ng for the gas-phase PAHs. According to the relationship between particulate-phase and gas-phase PAHs after smoking, the two- to four-ring gas-phase PAHs and the higher molecular weight particulate-phase PAHs were probably formed from similar precursors. The relationship between the total suspended particulate (TSP) concentration and the increase in the total particulate-phase concentration of the 16 PAHs per cigarette during smoking were significantly positive. The increase in the total gas-phase concentration of the 16 PAHs tended to increase as the TSP concentration increased. This may indicates that decreasing the amount of TSP produced inhibit the production of PAHs during smoking.

Effect of Anode Gas Channel Height on Gas Diffusion and Cell Performance in a Molten Carbonate Fuel Cell (용융탄산염 연료전지 연료극 기체 유로 높이에 따른 가스 확산 및 단전지 성능 변화 연구)

  • Lee, Jung-Hyun;Kim, Do-Hyung;Kim, Beum-Ju;Kang, Seung-Won;Lim, Hee-Chun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.479-484
    • /
    • 2009
  • The effect of anode gas channel height on gas diffusion and cell performance in a 100 $cm^2$ class molten carbonate single cell is investigated. Single cell separators with three different channel height are used. The effect of the gas channel height on the distribution of the reactive gas concentration is evaluated by the two-dimensional concentration diffusion equation. The overpotential caused by concentration drop with different channel height is estimated by the voltage decay related to diffusion of reactants, well known as concentration polarization, using limiting current density. The estimation could have the possibility to identify the reactant mass transfer polarization in the complicate factors of the overall electrodes.

Estimation of influening factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater (고농도 암모니아성 질소 폐수의 효과적인 혐기성 처리를 위한 영향 인자 평가)

  • Park, Seyong;Park, Junghoon;Na, Hoysung;Kim, Moonil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.5
    • /
    • pp.649-658
    • /
    • 2012
  • In this study, the influencing factors for efficient anaerobic digestion of high strength ammonia-nitrogen wastewater removal were investigated by testing biochemical methane potential test. In the influencing factors, the trace metals which could increase activity of anaerobic microorganisms, microbial concentration and types were evaluated. In the results, trace metals supplementation showed gas production amount higher than those without addition of trace metals. Among the tested trace metals, B, Ni, and Se were preferable to gas production. In the result of gas production according to the microbial concentration, the amount of gas production was proportional to the microbial concentration. In addition, the shortest lag time and the fastest gas production rate were achieved when the highest microbial concentration was tested. granule-type microorganism produced more gas than suspended-type microorganism. In conclusion, the efficient anaerobic digestion for high strength ammonia-nitrogen wastewater removal could be achieved by applying necessary trace metals injection and high concentration granule type microorganism.

A Study on Ammonia Formation with Nitrogen Impurity at a Natural Gas Steam Reforming Catalytic Process (소량의 질소를 포함한 천연가스 수증기 개질 반응에서 GHSV 변화에 따른 암모니아 생성 반응에 관한 연구)

  • KIM, CHUL-MIN;PARK, SANG-HYOUN;LEE, JUHAN;LEE, SANGYONG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.6
    • /
    • pp.601-607
    • /
    • 2019
  • Ammonia would be formed in natural gas containing small amount of nitrogen reforming process in the process natural gas, which might damage the Pt catalyst and Prox catalyst. In the article, the effect of nitrogen contents on the formation of ammonia in the reforming process has been studied. In the experiments, Ru based and Ni based catalysts were used and the concentration of ammonia in the reformate gas at various gas hourly space velocity was measured. Experimental result shows that relatively higher ammonia concentration was measured with Ru based catalyst than with Ni based catalyst. It also shows that the concentration of ammonia increased rapidly after most of the methane converted into hydrogen. Based on the experimental results to reduce ammonia concentration it might be better to finish methane conversion at the exit position of the reforming reactor to minimize the contact time of catalyst and nitrogen with high concentration of hydrogen.

Enhancement of HF Gas Removal Efficiency of a Scrubber in Semiconductor Manufacturing Process by using ANCOVA Technique (ANCOVA를 이용한 반도체공정 스크러버 HF 가스 제거 개선)

  • Kim, S.J.;Lee, M.;Xu, J.;Lim, S.;Lee, H.;Koo, J.
    • Journal of ILASS-Korea
    • /
    • v.18 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • To comply with the regulation of the reinforcing Clean Air Conservation Act, it is necessary for the semiconductor manufacturers to develop effective low-concentration acid gas abatement system to treat the flue gas. The low-concentration acid gas was found to be harder to deal with than the high-concentration one. In this study, the effect of various potential treatments such as air-assist nozzle spraying, magnetizing the scrubbing water, and adding surfactants to spraying and scrubbing water were investigate through the application of the statistical ANCOVA method, which was proved to be very useful tool when the inlet concentration of acid gas could not be controlled precisely and it affected the removal efficiency of the abatement system.

Funnel Design Guidance (Funnel 설계 권고안)

  • Jeong, Wang-Jo;Cho, Won-Ho;Kang, Dae-Youl;Kim, Seung-Hyuk
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.59-64
    • /
    • 2006
  • Most important factor to consider funnel performance is exhaust gas temperature and exhaust gas concentration Electric equipments on the wheelhouse top affected exhaust gas temperature. So, it is important that electric equipments keep away from high temperature. Though exhaust gas concentration is not a regulation and restraint, the exhaust 9as can cause serious problems for the on-board air quality and result in irreversible damage to the ship and people. So, we pocus on the exhaust gas concentration also. When judge whether a measured concentration is acceptable or not, criteria based on the LTEL (Long Term Exposure Limit). In this paper, we carried out the smoke simulation study. For this analysis, we used FLUENT which is commercial CFD (Computational Fluid Dynamics) code.

  • PDF

A Study on the Combustion Characteristics of Diesel Engine by the Change of the Intake Air Composition (흡기조성 변화에 따른 디젤 기관의 연소 특성 변화)

  • 김세원;임재문
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.91-96
    • /
    • 1994
  • Intake gases other than air, which is composed of oxygen, nitrogen, carbon dioxide, and argon, are used to study their effects on the performance of the diesel engine experimentally. The engine is operated at constant speed and fixed fuel injection timing, and cylinder pressure and heat release rate are measured at various intake gas compositions. The results show that increase of oxygen concentration improves the performance of the engine generally. The adverse effect is observed when the oxygen concentration is increased over the critical oxygen concentration of this test, mainly because of the over-shortened ignition delay. Increase of carbon dioxide concentration degardes the performance of the engine, mainly due to the lower specific heat ratio of carbon dioxide. Adding argon gas to the intake gas improves the overall performance. Finally, it is found that two most influencing factors affecting the performance of the diesel engine in this study are ignition delay and speific heat ratio of the intake gas.

  • PDF

A Study on the LPG Explosion Characteristics of Non-uniform Concentration (불균일 농도 LPG의 폭발 특성에 관한 연구)

  • 오규형
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.111-116
    • /
    • 2003
  • LPG explosion characteristics in non-uniform concentration was investigated with a 270 liter explosion vessel of which the scale is 100 cm${\times}$60 cm${\times}$45 cm. Vented explosion and closed explosion system were used. Experimental parameter were position of ignition source, nozzle diameter and flow rate of gas. Non uniform concentration was controlled by the nozzle diameter and flow rate. Explosion pressure were measured with strain type pressure sensor and the flame behavior was pictured with the video camera. Based on this experimental result, it was found that the flow rate of gas and the duration of gas injection are important factor for mixing the gas in the vessel. And as the increase the non-uniformity of gas concentration, explosion pressure and pressure rise rate Is decrease but the flame resident time in the vessel is increase. Therefore gas explosion to fire transition possibility will increase in non-uniform concentration gas explosion.

The study of combustion gas characteristic by incinerator operation condition. (소각로 운영조건에 따른 연소배가스 특성 연구)

  • Lee, Keon-Joo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2010
  • This study was done to analyze the condition of combustion exhaust gas that is produced according to incinerator operating condition in A area Kyonggido. The boiler exhaust gas temperature, the oxygen concentration of boiler, the outgassing temperature of Semi Drying Sorber(SDS), the temperature of catalytic reactor, the concentration of NOx, SOx, CO, Hcl and Dust were investigated by change the temperature of incinerator. The concentration of SOx, CO, HCL and DUST were below 5 ppm as increase the temperature of incinerator however the concentration of NOx was increased from 40 ppm to 70 ppm as increase the temperature of incinerator. The boiler exhaust gas temperature and the temperature of catalytic reactor were not changed however the oxygen concentration of boiler was decreased gradually as increase the temperature of incinerator.