• 제목/요약/키워드: Gas Valves

검색결과 180건 처리시간 0.035초

LNG 선박용 spring load 안전방출밸브의 유량 성능시험 (Flow capacity test of spring load safety relief valves used in LNG)

  • 박경암;이생희;김경권;고장훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2006
  • Many LNG ships will be constructed in Korea and the demand of safety valves is increasing. The most important performance of the developed safety relief valves for LNG ship is flow capacity. Flow capacity tests for 8 sizes of developed safety valves were conducted in the high pressure gas flow standard system in KRISS. The initial spring force adjustment was important for setting pressure of the safety valve. The procedure of data reduction and evaluation of the safety valve performance are suggested. This procedure was approved by French Bureau Veritas and Lloyd's Register.

  • PDF

특수가스용기용 밸브의 안전성에 관한 실험적 연구 (Experimental Study on the Safety of a Valve for a Special Gas Cylinder)

  • 김청균
    • 한국가스학회지
    • /
    • 제17권3호
    • /
    • pp.14-19
    • /
    • 2013
  • 본 연구에서는 특수가스용기용 밸브의 안전성에 관한 실험적 연구를 수행하였다. 시험용 밸브는 특수가스용기에 부착되었던 것을 무작위로 수거한 것으로 가스누출 및 작동 안전성에 대한 시험을 실시하였다. 실험결과에 의하면, 밸브의 몸체, 나사 체결부, 안전판, 방출구, 스템부, 핸들에서 가스누출 안전성에 영향을 미칠 정도의 크랙, 마모, 부식, 변형이 발생하지 않았다. 다만, 핸들의 페인트 일부가 벗겨지고, PT나사와 몸체에서 녹이 국부적으로 형성되어 있지만, 가스누출 안전성에 영향을 미칠 정도는 아니었다. 또한, 탈거한 밸브에서 가스누출은 발생되지 않았다. 다만, 밸브스템의 영구변형과 오링의 마찰표면 일부에서 손상이 관찰되었다. 따라서, 탈거된 밸브의 가스누출 안전성을 보장하기 위해서 밸브시트와 오링 교체하는 것이 바람직함을 알 수 있다. 또한, 핸들의 조임력을 주기적으로 점검하는 것이 필요함을 알 수 있었다.

화재 안전용 볼밸브의 열·구조 연성해석 (Thermal-structural Coupled Field Analysis for Fire Safety Type Ball Valve)

  • 김시범;이준호;이권희;전락원;도태완
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.28-32
    • /
    • 2011
  • The safety of transporting equipment in a cryogenic condition is one of important problems under the circumstances that the application weight of natural gas is gradually increasing. As a larger disaster may be generated by leakage of oil or gas from valves in case of fire occurrence of a ship, the present research applied a numerical analysis method on thermal stress distribution and deformation, etc. to the design of ball valves satisfying fire safety test's specification(API607) to prevent this. In addition, the present research progressed fire safety tests and compared the test result with numerical analysis results. The Max stress by parts was confirmed through thermal analysis of major parts to evaluate safety. The fire safety test was progressed according to the regulation of API607.

액화수소 수송용 진공자켓 밸브의 진공도에 따른 열적특성에 대한 연구 (A Study on the Thermal Characteristics of the Vacuum Jacket Valve for Transporting Liquefied Hydrogen According to the Degree of Vacuum)

  • 오승준;전경숙;윤정환;최정주
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.585-591
    • /
    • 2021
  • Liquefied hydrogen have advantage which reduces the volume by about 800 times or more compared to hydrogen gas, so it is possible to increase the storage density. However, liquefied hydrogen produced by cryogenic cooling of 20 K or less at normal pressure has a problem of maximizing the insulation effect that blocks heat introduced from the outside. Representative insulation technologies include vacuum insulation and multi-layer insulation materials and in general, heat blocking is attempted by combining insulation technologies. Therefore, in this study, the pressure of the internal vacuum layer was changed to 10-1, 10-2, 10-3 and 10-4 Torr to confirm the thermal insulation performance of the vacuum jacket valve for transporting liquefied hydrogen. As a result, it was confirmed that the insulation performance improved as the degree of vacuum increased.

LP가스용 차단기능형 수평식 용기밸브에 대한 설계연구 (Design Study of Automatic Cut-off Horizontal Valve for a LPG Cylinder)

  • 김청균
    • 한국가스학회지
    • /
    • 제19권6호
    • /
    • pp.80-84
    • /
    • 2015
  • 본 연구에서는 기존의 차단기능형 수직식 용기밸브와 새로이 개발된 수평식 용기밸브의 몸체전고와 중량에 대한 설계 데이터를 고찰하였다. 차단기능형 수평식 용기밸브의 전고는 기존의 차단기능형 수직식 용기밸브에 비해 41~42%나 획기적으로 줄어들었다. 또한, 수평식 밸브의 몸체 무게는 기존의 차단기능형 수직식 밸브에 비해 29~40%나 줄어든 결과를 얻었다. 이러한 결과는 단지 기존의 수직식 밸브에서 밸브의 여러 가지 구성요소를 수평식으로 배열을 바꾼 구조변경 설계를 통해 확보한 것이다.

가정용 가스보일러 과압방지밸브의 개발 연구 (Development of Relief Valves for the Domestic Gas-fired Hot Water Boilers)

  • 김영규;권정락;김지윤;서준석
    • 한국가스학회지
    • /
    • 제4권1호
    • /
    • pp.63-68
    • /
    • 2000
  • 가정용 가스보일러의 안전장치인 새로운 과압방지밸브를 개발하였다. 본 과압방지밸브는 방출용량을 고려하여 입출구의 구경과 시트구경을 확대하였고, 스프링과 난방수가 닿지 않는 밀봉구조로 설계하여 기존 과압방지밸브의 문제점인 입구유로의 고착, 막힘이나 스프링의 부식현상을 최소화하였다. 개발된 과압방지밸브는 시험결과 분출개시압력, 분출정지압력, 밀폐성, 내구성의 성능특성이 우수하였고, 보일러 설치후의 작동성도 우수한 것으로 평가되었다. 본 연구결과를 통한 과압방지밸브의 표준화와 적용은 부품호환뿐만 아니라 유지보수가 용이하다는 장점을 제공할 수 있을 것이다.

  • PDF

구조해석을 이용한 수소 연료전지 자동차 압력용기 밸브의 안전성 평가 (Safety Evaluation Based on Structural Analysis of Cylinder Valves for Fuel Cell Vehicles)

  • 이효렬;안중환;신진오;김화영
    • 한국생산제조학회지
    • /
    • 제25권3호
    • /
    • pp.189-197
    • /
    • 2016
  • Green vehicles include electric vehicles, natural gas vehicles, and fuel cell vehicles (FCVs). In FCVs, pressure vessels have cylinder valves to control hydrogen flow. These valves should be of high quality in terms of safety because hydrogen is stored at ultra-high pressure in pressure vessels. Hence, safety evaluation of these valves is necessary to secure the safety of the FCV. A structural analysis of the cylinder valve was conducted in this study by using a commercial finite element analysis code. The results showed that the safety factor of valve component ranged 1.06-186.44. After categorizing, the stress components at critical points of the cylinder valve parts were evaluated using the corresponding allowable design criteria in the ASME code. The pressurization cycle test was performed as per the regulation to evaluate the safety of the valve.

온도차 변동에 따른 전자밸브 작동모델 실험적 연구 (Experiment Study on Operation Model of Automatic Cylinder Valve by the Temperature Differences)

  • 장갑만;엄석화;김인찬;김청균
    • 한국가스학회지
    • /
    • 제16권6호
    • /
    • pp.73-79
    • /
    • 2012
  • 현재 국내의 모든 CNG자동차에는 용기용 밸브로 수동밸브가 부착되어 있으며 가스누출 사고 시 운전자가 차량을 정지하고 수동밸브를 잠궈야 하는 불편한 점이 있어 누출 사고 시에는 운전자 등이 가스누출사고를 대응하는데 어려운 부분이 있다. 유럽의 선진국에서는 가스누출 시 운전자가 시동을 끄면 자동으로 닫히는 구조를 가진 전자밸브의 장착을 의무화 하고 있어 우리나라에서도 기능성이 증가된 전자식 용기밸브를 적용하는 것이 CNG 버스의 안전성을 향상 시킬 수 있는 좋은 기회일 것이다. 본 논문에서는 개개의 전자밸브의 작동상태를 운전자가 파악하기 어려운 구조적인 문제를 보완하기 위해서 충전 중 압력의 상승에 따라서 온도가 상승하는 현상에 착안하여 문제에 접근하였다. 충전 중 온도상승이 압력차에 따라서 약 $30^{\circ}C$ 이상이 발생하는 것을 이용하여, 데이터 확인 시 온도상승이 발생하지 않는 용기는 밸브가 작동하지 않아 충전이 이루어지지 않는 것으로 판단할 수 있는 실험적 결론을 얻었다.

정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석(I) - 정압기 유동 해석 및 질량 유량 검증 - (Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station(I) - Flow Analysis and Mass Flow Rate Verification of Pressure Regulator -)

  • 권혁록;노경철;김영섭;이성혁
    • 한국가스학회지
    • /
    • 제12권2호
    • /
    • pp.99-104
    • /
    • 2008
  • 가스 정압기지 내의 가스 정압기는 배관 내의 높은 가스의 압력을 일정한 압력으로 낮추는 역할을 한다. 가스 정압기는 흐르는 가스의 유동을 제어할 뿐 아니라, 하류의 압력을 제어하는 데도 사용한다. 가스 정압기지의 안전성을 위해서 정압기와 정압기에 연결되어 있는 안전밸브의 유동 특성을 파악하는 것은 필수적이다. 따라서 본 연구에서는 정압기의 질량 유량 및 유동 특성을 다양한 입구 및 출구 압력 조건, 그리고 개도율에 대하여 수치해석 방법을 이용하여 알아보았다. 이러한 질량 유량에 대한 수치해석 결과는 정압기 제조사로부터 제안되는 실험 수식을 통하여 검증하였다. 결론적으로, 수치해석 결과와 실험 수식을 통해 얻어진 결과가 잘 일치함을 알 수 있다.

  • PDF

EXPERIMENTS ON THE PERFORMANCE SENSITIVITY OF THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN ADVANCED INTEGRAL TYPE REACTOR

  • Park, Hyun-Sik;Choi, Ki-Yong;Choi, Seok;Yi, Sung-Jae;Park, Choon-Kyung;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2009
  • A set of experiments has been conducted on the performance sensitivity of the passive residual heat removal system (PRHRS) for an advanced integral type reactor, SMART, by using a high temperature and high pressure thermal-hydraulic test facility, the VISTA facility. In this paper the effects of the opening delay of the PRHRS bypass valves and the closing delay of the secondary system isolation valves, and the initial water level and the initial pressure of the compensating tank (CT) are investigated. During the reference test a stable flow occurs in a natural circulation loop that is composed of a steam generator secondary side, a secondary system, and a PRHRS; this is ascertained by a repetition test. When the PRHRS bypass valves are operated 10 seconds later than the secondary system isolation valves, the primary system is not properly cooled. When the secondary system isolation valves are operated 10 or 30 seconds later than the PRHRS bypass valves, the primary system is effectively cooled but the inventory of the PRHRS CT is drained earlier. As the initial water level of the CT is lowered to 16% of the full water level, the water is quickly drained and then nitrogen gas is introduced into the PRHRS, resulting in the deterioration of the PRHRS performance. When the initial pressure of the PRHRS is at 0.1MPa, the natural circulation is not performed properly. When the initial pressures of the PRHRS are 2.5 or 3.5 MPa, they show better performance than did the reference test.