• 제목/요약/키워드: Gas Resistance

검색결과 1,361건 처리시간 0.028초

Gas Sensing Properties of $MgO-Cr_2O_3-TiO_2$ Oxide ($MgO-Cr_2O_3-TiO_2$ 산화물의 가스감지 특성)

  • 양천회;홍필선;유일증;임병오
    • Journal of the Korean Society of Safety
    • /
    • 제1권1호
    • /
    • pp.21-26
    • /
    • 1986
  • Gas sensing materials for detecting inflammable gas such as alcohol, propane, acetic acid, carbon monoxide, hydrogen were developed by utiliting $MgO-Cr_2O_3-TiO_2$ system. Between 30$0^{\circ}C$ and 50$0^{\circ}C$, reversible chemisorption becomes dominant and the electrical canduction of P-type semiconductive with the gas chemisorption. The ceramic sensor exhibits a high sensitivity to particular reducing gas such as alcohol, whereas propane and butane have little effect on the resistivity. The time response of adsorption is estimated to be about 20 sec. On the other hand, the desorption process, which corresponds to oxidation due to oxygen adsorption, take more than 60 sec. Thus the ceramic sensor can be used as a alcohol sensor in an ambient aunosphere. As the oxygen concentration is increased from 0.1 to 10 precent($10^3-10^6ppm$), the resistance decreases rapidly but stabilizes at higher concentration.

  • PDF

Fabrication and Mechanical Properties of A356/SiCp Manufactured by Gas-Particle Co-injection Method (가스-입자 동시주입법에 의한 A356/SiCp 복합재료의 제조 및 기계적 특성)

  • Lee, Jung-Mu;Kang, Suk-Bong;Eum, Chil-Yong;Lim, Cha-Yong
    • Journal of Korea Foundry Society
    • /
    • 제21권1호
    • /
    • pp.33-40
    • /
    • 2001
  • Among the many techniques available to synthesis metal matrix composites, liquid phase processing, especially, conventional casting process such as stir-casting process is particularly attractive for their simplicity, economy and flexibility, In the present study, A356/20%SiCp composites were fabricated by gas-particle co-injection method. The gas-particle co-injection method is a modified stir-casting method and the corporation of particle could be improved by acceleration of particles due to rotation of impeller and gas purging. The microstructures and mechanical properties such as tensile properties and resistance to wear of fabricated materials were examined. Further, the particle injection mechanism in gas-particle co-injection method was discussed.

  • PDF

Operation and Improvement Cases of FGD Non-leakage Type Gas-Gas Heater(GGH) for Coal Fired Power Plants (석탄화력 탈황설비 Non-leakage Type Gas-Gas Heater(GGH) 운영 및 개선사례)

  • Seong, Kijong;Lee, Changsik
    • Journal of the Korean Society of Combustion
    • /
    • 제22권4호
    • /
    • pp.35-42
    • /
    • 2017
  • This case covers the issues related to the operation problem, cause analysis and improvement cases of the FGD that employed the non-leakage type GGH in coal-fired power plant for the first time in Korea. In the Cooler, there was a main problem that the tube is damaged by the ash cutting due to the high velocity of flue gas in the duct and by the weak wear resistance of material. In the Reheater, there was a main problem that the tube was corroded due to chlorine and sulfur in the circumstance of the low temperature. In order to solve those problems, we have improved the Reheater tube and tube fins by coating enamel to reduce corrosion rate.

High Strength Low Alloy Steel for Sour Service

  • Jung, Hwan Gyo;Kim, Sang Hyun;Yang, Boo Young;Kang, Ki Bong
    • Corrosion Science and Technology
    • /
    • 제7권5호
    • /
    • pp.288-295
    • /
    • 2008
  • The increase use of natural gas as an energy source has been continuous demand for ever-increasing strength in gas transmission pipeline materials in order to achieve safe and economic transportation of natural gas. In particular, linepipe material for sour gas service primarily needs to have crack resistant property. However, applications of sour linepipes are expanding toward deep water or cold region, which require higher toughness and/or heavier wall thickness as well as higher strength. To improve the crack resistance of linepipe steel in sour environment, low alloy steel are produced by controlled rolling subsequently followed by the accelerated cooling process. This paper summarizes the design concepts for controlling crack resistant property low alloy linepipe steels for sour gas service.

Corrosion Rate of Buried Pipeline by Alternating Current

  • Song, H.S.;Kim, Y.G.;Lee, S.M.;Kho, Y.T.;Park, Y.S.
    • Corrosion Science and Technology
    • /
    • 제4권1호
    • /
    • pp.1-7
    • /
    • 2005
  • An alternating current (AC) corrosion on buried pipeline has been studied using coupon and ER probe. Coupons and ER probes were applied to the sites from high value of AC voltage to low value based on the survey of AC voltages on buried gas transmission pipeline over the country. Parameters such as AC current density of coupon, AC voltage, cathodic protection potential, soil resistivity and frequency were monitored continually. Corrosion induced by AC was observed even under cathodically protected condition that met cathodic protection criterion (; below -850 mV vs. CSE). Corrosion rate was affected mainly not by AC voltage but by both of frequency and AC current density. An experimental corrosion rate relation could be obtained according to effective AC current density, in which AC corrosion rate increased linearly with effective AC current density, and its slope was 0.619 in coupon method and 0.885 in ER probes.

EFFECTS OF GAS PRESSURES ON GRANULAR STRUCTURE'S FOR MATION OF ALUMINUM FILMS PREPARED BY PVD PROCESS

  • Lee, Myeong-hoon
    • Journal of the Korean institute of surface engineering
    • /
    • 제29권5호
    • /
    • pp.585-592
    • /
    • 1996
  • In order to investigate the influence of gas pressure in PVD deposition conditions, aluminum films were prepared by vacuum evaporation and ion plating. The crystal orientation and morphology of the films affected by argon gas pressures were characterized by using X-ray diffraction (XRD) and scanning electron micrography (SEM) respectively. With the increasing of argon gas pressure, the preferred orientation of aluminum films exhibited (200) and the diffraction peaks of the films became less sharp and broadened. Film's morphology changed from columnar structure to granular structure with the increase of gas pressure. And the properties of these films on corrosion behaviors were estimated by measuring anodic polarization curves in deaerated 3% NaCl solution. The aluminum films which exhibited granular structure with (200) preferred orientation showed good corrosion resistance.

  • PDF

Fabrication of Gas-permeable Die Materials Having Orthogonally Arrayed Pore Channels

  • Chan, Tien-Yin;Lin, Shun-Tian;Chang, Hua-Jun;Chen, Chia-Liang
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.97-98
    • /
    • 2006
  • Gas-permeable metal die materials are developed using tool steel powder, packed in a mold having the insertion of orthogonally arrayed polymer wires. Linear gas-permeable channels in orthogonal array are thus developed by the burning out of the polymer wires, which yield a microstructure with wear resistance value and air permeability much larger than those of the conventional gas-permeable die material.

  • PDF

NOx Sensing Characteristics of the $WO_{3}$-Based Thin-Film Gas Sensors (박막형 $WO_{3}$계 가스센서의 NOx 감도 특성)

  • Yoo, Kwang-Soo
    • Journal of Sensor Science and Technology
    • /
    • 제5권5호
    • /
    • pp.39-46
    • /
    • 1996
  • The Pd or Pt-doped $WO_{3}$ thin-film NOx sensor was fabricated. The $WO_{3}$-based thin films as a gas-sensing layer were deposited at ambient temperature in a high-vacuum resistance heated evaporator and annealed at $500^{\circ}C$. The gas sensitivity ($R_{gas}/R_{air}$) to 5 ppm $NO_{2}$ measured at the operating temperature of $300^{\circ}C$ was 50 (highest sensitivity) for the 0.5 wt.% $Pt-WO_{3}$ sensor.

  • PDF

The Sensor Response for CO Gas of $LaMO_3$ and $LaFe_{1-x}CO_xO_3$ in Perovskite Type Oxides (Perovskite형 산화물 $LaMO_3$$LaFe_{1-x}CO_xO_3$의 일산화탄소가스에 대한 센서 응답 특성)

  • 임병오;손태원;권동혁
    • Journal of the Korean Society of Safety
    • /
    • 제3권1호
    • /
    • pp.7-13
    • /
    • 1988
  • The oxides in perovskite type, $LaMO_3$ (M=Ni, Cr, Fe, Co), compared with gas sensors which have been used, were synthesised and then examined sensor response comparatively in order to make a thick film gas sensor having a good gas selectivity, durability and simple manufacturing. The oxides in perovskite type, $LaFe_{1-x}O_3$ (x=0.2, 0.4, 0.6, 0.8), which a part of Fe was replaced with Co, were examined with regard to their electric resistance with variable temperature and sensor response for carbon monoxide gas.

  • PDF

Sub-ppm level MEMS gas sensor (서브 피피엠 레벨 미세기전 가스 센서)

  • Ko, Sang-Choon;Jun, Chi-Hoon;Song, Hyun-Woo;Park, Seon-Hee
    • Journal of Sensor Science and Technology
    • /
    • 제17권3호
    • /
    • pp.183-187
    • /
    • 2008
  • A sub-ppm level MEMS gas sensor that can be used for the detection of formaldehyde (HCHO) is presented. It is realized by using a zinc oxide (ZnO) thin-film material with a Ni-seed layer as a sensing material and by bulk micromachining technology. To enhance sensitivity of the MEMS gas sensor with Ni-seed layer was embedded with ZnO sensing material and sensing electrodes. As experimental results, the changed sensor resistance ratio for HCHO gas was 9.65 % for 10 ppb, 18.06 % for 100 ppb, and 35.7 % for 1 ppm, respectively. In addition, the minimum detection level of the fabricated MEMS gas sensor was 10 ppb for the HCHO gas. And the measured output voltage was about 0.94 V for 10 ppb HCHO gas concentration. The noise level of the fabricated MEMS gas sensor was about 50 mV. The response and recovery times were 3 and 5 min, respectively. The consumption power of the Pt micro-heater under sensor testing was 184 mW and its operating temperature was $400^{\circ}C$.