• Title/Summary/Keyword: Gas Pressure Regulator

Search Result 52, Processing Time 0.033 seconds

Overpressure Prevention of Pipeline Attached to Outlet of LPG Vaporizer (온수전열식 기화기 후단 배관내 가스의 이상압력상승 방지방안에 관한 연구)

  • Park Kyo-Shik;Park Heui-Joon;Kim Ji-Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.62-68
    • /
    • 2001
  • Overpressure in pipeline attached to outlet of LPG vaporizer has been studied to provide countermeasures to prevent it. The cause of liquefaction in pipeline was reviewed using vapor pressure curve with temperature, pressure, and composition to suggest method of controlling such parameters. Performance of vaporizer has been tested to detect defective design of float ball, and then improved scheme was suggested. Trouble of regulator attached to vaporizer was also studied to give countermeasures.

  • PDF

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong;Kwon Boo-Kil
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.329-334
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performances of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after about six-year-use of the regulators.

Development of a Shut-off Device of LP Gas Regulator for Home Use (가정용 LP가스 조정기 차단안전장치의 개발)

  • Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.54-59
    • /
    • 2006
  • A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.

  • PDF

Study on the Plan to Reduce the EVENT of the Gas Regulator (정압기 EVENT 감소방안 연구)

  • Kang-ok Yun;Tae-jun Eom;Ki-beom Kim;Yong-woo Lee;Hyoung-Min Lee;Byeong-Geun Gong
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • The Gas Regulator EVENT is a signal sent by the Remote Terminal Unit(RTU) installed in each local gas regulator (hereinafter referred to as "regulator"), and is an abnormal alarm that can be intuitively checked in our client server. This is an important data that enables immediate dispatch order and initial action in the situation room when a regolator abnormality occurs, and can analyze the cause of the regulator abnormality. Looking at the trend of EVENT data for regulator over the past three years, there is a clear trend of increasing unchecked EVENT data. The increase in non-checking event (actual abnormality or noise event) may mean that firstly, mechanical or pressure abnormality occurs in the actual regulator, and secondly, there is no abnormality in the actual regulator, but communication error occurred in the RTU, reset. EVENT Data may be formed as if an abnormality occurred in the static voltage due to an error, sensor error, power failure (instantaneous power failure), etc. Among them, this study analyzed the recently generated unchecked EVENT data to identify critical noise events among RTU errors, which are noise events, and reviewed ways to increase the reliability of Regulator EVENTs by reducing them.

Numerical Analysis for Evaluation of Ejection Capacity Relationship of Safety Valves in Pressure Regulating Station (II) - Flow Analysis and Required Effective Discharge Area of Safety Valve - (정압기지내의 안전밸브 분출용량 관계식 검증을 위한 유동해석 (II) - 안전밸브 유동 해석 및 필요분출면적 -)

  • Gwon, Hyuk-Rok;Roh, Kyung-Chul;Kim, Young-Seop;Lee, Seong-Hyuk
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.105-109
    • /
    • 2008
  • A safety valve has a valve mechanism for the automatic release of gas from piping system when the pressure exceeds preset limit cause of a defect of a pressure regulator, condensation of water in a pipe. Therefore, for the safety of pressure regulating station, it is essential to study the flow regime and characteristics of safety valve. This article presents the numerical analysis on the flow analysis, the ejection capacity and required effective discharge area of the safety valve that is established in pressure regulating station. Then, the results are compared and analyzed with domestic and foreign regulations such as API(America Petroleum Institute), EN(European Standard), and NF(Norme Francise). Moreover, the installation number of safety valve is considered by using domestic and foreign regulations and maximum reguired effective discharge area of safety valve.

  • PDF

Experimental Studies on the Aging Characteristics by Service Periods of Regulator Diaphragms at Governor Room of City Gas (도시가스 정압기용 압력조정기 다이어프램의 사용기간에 따른 경년특성에 관한 실험적 연구)

  • Lee, Chi-Woo;Park, Dal-Jae
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.104-108
    • /
    • 2018
  • Experimental studies have been done to examine the aging characteristics by regulator diaphragms of gas pressure, governor room of city gas. Various testing samples with different service periods were manufactured. The results of SEM observation indicated that the surface and thickness of the samples tested were slightly sensitive to the service periods. It was found that as the service periods increased, the tensile strength of diaphragm samples decreased. For samples over 25 years of service, the strength decreased to approximately 60 % of that of new diaphragms. It was also found that as the service periods increased, the elongation increased.

Study for Fire Examples of LPG Leakage Including Fuel hose, Injector and Pressure Regulator Connector in Vehicle (자동차 연료호스, 인젝터 및 압력조절기 연결부에서 LP 가스 누출에 의한 화재사례 고찰)

  • Lee, Il Kwon;Kook, Chang Hoo;Suh, Moon Won;Jung, Dong Hwa
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.3
    • /
    • pp.8-13
    • /
    • 2013
  • The purpose of this paper is to study for fire example by fuel leakage in LPG Vehicle. At first example, the car was repaired the fuel line that was connected with pressure hose between fuel regulator and injector in engine. But the service man was not very tighten with regular torque. At a result, the gas leaked on hot parts of engine. It verified the production of fire by engine heat. At second example, when the repair man, after replacement the injector, inserted the injector in a assembling part of it, he didn't the transform condition of fixing part. Therefore, the tearing phenomenon of O ring producted the controlled leakage of fuel by the injector deflection. It found the fact that the fuel leaked with gap of O ring. At third example. the fuel-cut solenoid valve was lined with pressure regulator unit. But the service man didn't throughly certify the leaked work of connected parts after repaired it. As a result, it certified the fire by engine heating leaked liquefied petroleum gas. Therefore it have to minimize the fire production that the driver should do no problem to throughly manage the fuel system.

Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter (스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발)

  • Jung-Hoon Kim;Jung-Suk Oh;Jin-Han Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.57-64
    • /
    • 2023
  • As the meter reading method of gas meters develops, smart gas meters capable of remote meter reading (leak checking meters and multi-function safety meters) are being used. These meters have a function to judge leakage by utilizing the flow rate and pressure data collected as an additional function. Leakage judgment function using flow rate data has valid cases in the actual field, but the pressure data-based leakage judgment standard is based on not only the pressure value change due to leakage but also various factors (pressure regulator pressure, connection with adjacent meters, usage of adjacent houses, location of meters, etc.). There is a problem with pressure magnitude changes (levels). In this paper, as a technique that can judge leaks by using pressure data collected from smart gas meters, it was developed through preprocessing of pressure data, criteria for pressure value ranges related to leaks, leak judgment techniques, and application case verification.

Optimum Design Method for Pressure-reducing System using High-pressure Gas (고압가스감압시스템 최적화 설계기법)

  • Chung, Yong-Gahp;Cho, Nam-Kyung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.748-751
    • /
    • 2010
  • To launch rocket on launch pad, propellants and gases are charged into the rocket by remote control system. Using pneumatic pressure-reducing regulators, kinds of gases with various pressure levels are supplied into launch pad. As most of operations for launching the vehicle are remotely controled in the launch control room, pressure pulsations due to rapidly gas supply at the upstream of regulators can make the required operating pressure range missed and cause damage to the regulators. In this paper, the optimum design methods of pressure regulators of pressure-reducing system on launch pad using high-pressure gases were investigated to solve the aforementioned problems and for stable gas supply to launch pad.

  • PDF

A Study of Fluid Structure Interaction Analysis and Coating Characteristics of a Two-stage Pressure Reduction Hydrogen Regulator (2단 감압 수소레귤레이터의 연성해석 및 도금특성에 관한 연구)

  • Song, Jae-Wook;KIM, Seung-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.37-44
    • /
    • 2021
  • In this study, shape design and material selection were carried out for a two-stage pressure-reducing regulator to compensate for the shortcomings of a one-stage mechanical decompression regulator. The shape of the contact surface of the depressurization unit was considered, material was selected, and the shape was designed to compensate for the pulsation and slow response through the two-stage decompression and to solve the problem of high pressure deviation. In terms of airtightness, the deformation amount of TPU showed a small amount of displacement of up to 15.82%. Considering the fact that it is applicable to various hydrogen fuel supply systems by securing universality by applying electronic solenoids to the second pressure reduction, magnetic materials were selected. The hydrogen embrittlement and corrosion resistance were evaluated to verify the plating process. Surface corrosion did not occur in only the case of Cr plating. The elongation during the corrosion process was compared using a tensile test, and there was a difference within 2%.