• Title/Summary/Keyword: Gas Permeability

Search Result 532, Processing Time 0.023 seconds

Effects of the Nitrile Group Substitution on the Gas Separation Properties of Aromatic Polyamide Membranes

  • Park, Ho-Seung;Jo, Won-Ho;Oh, Tae-Jin;Kang, Yong-Soo;Park, Hyun-Chae
    • Fibers and Polymers
    • /
    • v.1 no.2
    • /
    • pp.111-115
    • /
    • 2000
  • The effects of nitrile group substitution onto aromatic polyamide backbone on the gas permeability and permselectivity of the polymers are examined. The gas permeability of aromatic polyamides increase with increasing the content of nitrile group substitution, whereas the permselectivity decreases with increasing the nitrile group contents. The effects of chain linrearity on the permeability and permselectivity are also examined. The non-linearity of the polymers increases the permeability. These behaviors are interpreted in terms of chain packing and crystallinity of the aromatic polyamides.

  • PDF

Experimental Study on the Measurement of the Low Permeability in Tight Gas Reservoir (치밀가스 저류층의 저투과도 측정에 관한 실험적 연구)

  • Jang, Ho-Chang;Shin, Chang-Hoon;Lee, Jeong-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.20-30
    • /
    • 2014
  • To develop a unconventional gas reservoir, an analysis of tight rock property are required. Especially, conventional measurements are difficult to be applied to unconventional resources such as tight gas reservoir because the permeability are extremely low compared to a conventional gas reservoir. In this study, an apparatus was developed for measuring low permeability and porosity based on a pressure pulse decay method under unsteady state conditions. The apparatus was applied for measuring the porosity and permeability of tight sand core samples from Gyeongsang basin in Korea. As a validation of the measurement, regression analysis was carried out using the dimensionless pseudo-pressure between the measured data and analytical solution. The results show the correlation coefficients above 0.96. Therefore, it is believed that the apparatus has a high accuracy.

Synthesis of Highly Selective Polyimide Material and Comparison of Gas Permeability by Molecular Dynamics Study (고선택성 폴리이미드 소재의 합성 및 분자동력학 연구를 통한 기체투과도의 비교)

  • Lee, Jung Moo;Kim, Deuk Ju;Jeong, Moon Ki;Lee, Myung Gun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.162-170
    • /
    • 2015
  • In this study, gas permeability of polyimide materials having a various amine group was measured and molecular dynamics was used to analyze the dynamic characteristics of the gas molecules in the polyimide by calculating the position and velocity of the gas molecules with change of the time. The gas permeability of polyimide membrane having substitution site which increase free volume in the polymer was increased. However, polyimide with rigid structure showed decreased gas permeability. As a result of analyzing the change in the gas permeation behavior using molecular dynamics simulations, we confirmed that the results show the same tendency with actual measurements of the gas permeability.

A Study on the Permeability and Chloride lon Penetration of Concrete (물-시멘트비에 따른 콘크리트의 투과성 및 염화물 이온의 침투성에 관한 연구)

  • 형원길;소형석;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.179-184
    • /
    • 1998
  • The permeability of concrete influences the durability of concrete remarkably. This paper describes a programme of permeability tests carried out to determine the differences between permeability coefficients derived using water, oxygen and chloride ions. Tests have been carried out on three concretes having water/cement ratios of 0.45, 0.55, 0.65 to measure their water, chloride-ion and gas permeability coefficients. The test results indicate that the permeability of concrete increase with the increase water cement ratios. The water and gas permeability coefficients is presented from $1.43$\times$10^{-10} to 19.01$\times$10^{-10}m/s$ and from $0.88$\times$10^{-10}$ to $1.59$\times$10^{-10}$m$^2$for concrete of different water cement ratios. The current intensity passing through the concrete is presented from 4504 to 4920 C.

  • PDF

Comparison of the Mercury Intrusion Porosimerty, Capillary Flow Porometry and Gas Permeability of Eleven Species of Korean Wood

  • Jang, Eun-Suk;Kang, Chun-Won;Jang, Sang-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.681-691
    • /
    • 2018
  • The typical methods of mercury intrusion porosimetry (MIP) and capillary flow porometry (CFP) were used to evaluate the pore size of cross-section of wood and the effect of the pore structure on the permeability of wood was analyzed in this study. The results of this study were as followings: The pore size of wood measured by CFP was larger than that measured by MIP except for Lime tree, Korean red pine and Paulownia. Among the three pore types of porous materials defined by IUPAC (through pores, blind pores, and closed pores), only through pores are related to permit fluid flow. MIP measures the pore size of both through pores and blind pores, while CFP measures the pore size of only constricted through pores. Therefore, pore size measured by MIP was not related to gas permeability, however pore size measured by CFP had a proportional relationship with gas permeability.

Facilitated Transport Separation of Carbon Dioxide Using Aminated Polyetherimide Membranes (아민화된 폴리이서이미드 막을 이용한 이산화탄소의 촉진수송분리)

  • Kwon, Se Hwan;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.25 no.3
    • /
    • pp.248-255
    • /
    • 2015
  • Aminated polyetherimide membrane synthesized in the laboratory according to amine ratio was used for measurement of gas permeability, diffusivity, and solubility about carbon dioxide, nitrogen, methane, oxygen, and sulfur dioxide with Time-lag method at room temperature. Generally, gas permeability is totally decreased because the more amination rate reacted to the main chain of amine groups, the more intermolecular space became narrow. However, gas permeability of sulfur dioxide was increased due to combination of sulfur dioxide and amine groups have acid and base properties respectively. Diffusivity and solubility of dry gas are totally decreased excluding sulfur dioxide as increasing amination rate. In case of sulfur dioxide, however, diffusivity as well as solubility was increased as increasing amination rate. Selectivity of carbon dioxide/nitrogen showed 60 when amination rate was 3. In case of humid gas, gas permeability of carbon dioxide was 70 barrer when relative humidity showed 100, and selectivity with nitrogen approximately showed 18.

Performance Test of Silicone Rubber Membrane by Gas Permeation Method (기체투과에 의한 Silicone Rubber Membrane의 기능성 시험)

  • Lee, Seung-Bum;Hong, In-Kwan
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 1998
  • The permeation of gas through polymer membrane at temperatures above its glass transition, generally occurs by a solution-diffusion mechanism. This mechanism is performed by the affinity difference between polymeric materials and gas molecules, and various technologies, such as copolymerization, impregnation and so on, have been researched to improve the affinity of polymeric material for the gases. In this study, permeability and selectivity for some gases were obtained from steady-state rates of gas permeation through silicone rubber membrane which is prepared by supercritical fluid extraction method. The permeability was measured by the volumetric method proposed by Barrer. Permeability was increased generally with temperature and permeation pressure. Silicone rubber membrane shows a higher permeability to $CO_2$ than to $O_2$, $N_2$. This results probably reflect the relatively high solubility of CO_2 in silicone rubber membrane, which is due to the affinity of $CO_2$ molecules. Since separation powers of $CO_2/N_2$, $CO_2/O_2$ were more than 200, and 100, respectively, it is able to separate $CO_2$ from the air, and the optimum temperature and pres-sure was 328.15 K, 60 cmHg respectively. In future, it is possible that the silicone rubber membrane can be used for separation or concentration of $CO_2$ through experiment for mixed gas separation.

  • PDF

Permeability of the Lateral Air Flow through Unstructured Pillar-like Nanostructures (비정형 기둥 형상을 가진 나노구조에서의 가스 투과성 실험 연구)

  • Hyewon Kim;Hyewon Lim;Jeong Woo Park;Sangmin Lee;Hyungmo Kim
    • Tribology and Lubricants
    • /
    • v.39 no.5
    • /
    • pp.197-202
    • /
    • 2023
  • Recently, research on experimental and analytical techniques utilizing microfluidic devices has been pursued. For example, lab-on-a-chip devices that integrate micro-devices onto a single chip for processing small sample quantities have gained significant attention. However, during sample preparation, unnecessary gases can be introduced into the internal channels, thus, impeding device flow and compromising specific function efficiency, including that of analysis and separation. Several methods have been proposed to mitigate this issue, however, many involve cumbersome procedures or suffer from complexities owing to intricate structures. Recently, some approaches have been introduced that utilize hydrophobic device structures to remove gases within channels. In such cases, the permeability of gases passing through the structure becomes a crucial performance factor. In this study, a method involving the deposition and sintering of diluted Ag-ink onto a silicon wafer surface is presented. This is followed by unstructured nano-pattern creation using a Metal Assisted Chemical Etching (MACE) process, which yields a nanostructured surface with unstructured pillar shapes. Subsequently, gas permeability in the spaces formed by these surface structures is investigated. This is achieved by experiments conducted to incorporate a pressure chamber and measure gas permeability. Trends are subsequently analyzed by comparing the results with existing theories. Finally, it can be confirmed that the significance of this study primarily lies in its capability to effectively evaluate gas permeability through unstructured pillar-like nanostructures, thus, providing quantitative values for the appropriate driving pressure and expected gas removal time in practical device operation.

Application of Molecular Simulation Techniques to Estimation of Gas Permeability in Zeolite Membranes

  • Takaba, Hiromitsu;Yamamoto, Atsushi;Nakao, Shin-Ichi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.33-38
    • /
    • 2004
  • Molecular modeling of gas permeation through zeolite membranes with/without intercrystalline region was carried out. Molecular dynamics (MD) and Monte Carlo (MC) simulations were performed to estimate the diffusion coefficient and adsorption parameters respectively, and our proposed combined method of molecular simulation techniques with a permeation theory (CMP) was used to estimate gas permeability. The calculated permeability of gases (Ar, He, Ne, $N_2$, $0_2$, $CH_4$) at 301 K for the single crystal membrane model was about one order of magnitude larger than the experiential values, although the dependence on the molecular weight of the permeating species agreed with experiments. On the other hand, the estimated permeability using the diffusivity and adsorption parameters of the intercrystalline region model was in good agreement with the experiments. The consistency between experiments and the estimated values means the importance of considering the intercrystalline region and the validity of CMP method to predict the performance of zeolite membranes.

  • PDF

Gas permeation property of organic-inorganic hybrid membrane made by ion-beam irradiation

  • Kawakami, Hiroyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.90-93
    • /
    • 2004
  • In this study, we have reported an organic-inorganic hybrid membrane, which exhibits an asymmetric structure consisted of a carbonized skin layer and a polyimide porous substructure, to synthesize a novel gas separation membrane combining high gas permeability and selectivity. Both the gas permeability and selectivity of the carbonized layer significantly enhanced when compared with those determined in the control polyimide.

  • PDF