• 제목/요약/키워드: Gas Insulated Switchgear(GIS)

검색결과 188건 처리시간 0.029초

초고압 절연 스페이서의 자동가압 겔화 성형 공정을 위한 경화 보압의 최적화 (Optimization of Curing Pressure for Automatic Pressure Gelation Molding Process of Ultra High Voltage Insulating Spacers )

  • 이찬용;조한구;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.56-62
    • /
    • 2024
  • By introducing curing kinetics and chemo-rheology for the epoxy resin formulation for ultra-high voltage gas insulated switchgear (GIS) Insulating Spacers, a study was conducted to simulate the curing behavior, flow and warpage analysis for optimization of the molding process in automatic pressure gelation. The curing rate equation and chemo-rheology equation were set as fixed values for various factors and other physical property values, and the APG molding process conditions were entered into the Moldflow software to perform optimization numerical simulations of the three-phase insulating spacer. Changes in curing shrinkage according to pack pressure were observed under the optimized process conditions. As a result, it was confirmed that the residence time in the solid state was shortened due to the lowest curing reaction when the curing holding pressure was 3 bar, and the occurrence of deformation due to internal residual stress was minimized.

Dielectric Properties of Epoxy/Micro-sized Alumina Composite and of Epoxy/Micro-sized/Nano-sized Alumina Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권6호
    • /
    • pp.338-341
    • /
    • 2015
  • Epoxy/micro-sized alumina composite was prepared, and the effects of alumina content on the dielectric properties were investigated in order to develop an insulation material for gas-insulated switchgears (GIS). Nano-sized alumina (average particle size: 30 nm) was also incorporated into the epoxy/micro-sized alumina composite. Dielectric tests were carried out in ASTM D 150, and capacitance (Cp) and dielectric loss (tanδ) were measured. The dielectric constant increased with increasing alumina content in the epoxy/micro-alumina system and the epoxy/micro-alumina/nano-alumina system. As 1,3-diglycidyl glyceryl ether (DGE) content increased, the dielectric constant decreased and dielectric loss increased. This ocurred as a result of the weak electric field enhancement due to homogeneous dispersion of micro- and nano-sized alumina particles in an epoxy composite.

P.C.에 의한 GIS형 AC Substation의 접지계 설계 (Grounding System Design of GIS type AC Substation using Personal Computer)

  • 임한석;김왕
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제4권1호
    • /
    • pp.46-53
    • /
    • 1990
  • GIS(Gas-Insulated Switchgear)형 옥내변전소에 있어서 접지계의 구성은 접지도체를 포설할 수 있는 면적이 협소하기 때문에 특별한 설계방법이 요구된다. 본 논문에서는 접지망의 전위해석과 축소형 변전소의 접지계 설계기법을 제시하였고, 아울러 컴퓨터 시뮬레이션을 위한 프로그램을 작성하고 그 시뮬레이션 결과를 측정치와 비교하여 프로그램의 타당성을 입증하였다.

  • PDF

25.8kV 친환경절연 개폐장치 실계통 적용 방식 및 고장사례 연구 (A Study on fault cases of 25.8kV Environment-friendly Insulated Switchgear and its its application to real power system)

  • 최상철;조필훈;이봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.189-190
    • /
    • 2011
  • 현재 변전소에서 일반적으로 사용되는 송변전기기 개폐장치인 GIS(GAS Insulated Switchgear)는 절연확보를 위해 외함 내부에 SF6 GAS가 충진되는 구조이다. SF6 GAS는 지구온난화 규제 물질에 해당하는 가스로 아크 및 부분방전 등에 의해 유독물질로 분해되는 특징이 있어 개폐장치의 내부 절연물로 친환경 매질로의 전환이 절실한 실정이다. 최근 KEPCO는 25.8kV GIS를 대체할 친환경절연 개폐장치를 도입하고 시범 운영중에 있으며, 그 결과에 따라 확대 적용할 방침이다.

  • PDF

초고압 GIS 모선의 통전설계를 위한 교류자계해석 (Ac Magnetic Field Analysis of Current Carrying Conductor Design for EHV GIS)

  • 김현훈;이정섭;한성진;정진교;이병윤;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권5호
    • /
    • pp.233-240
    • /
    • 1999
  • The current carrying conductor and the tank which consist of GIS must be properly designed to withstand the electrical, thermal and mechanical stresses that arise during normal service and during short-circuit conditions. In order to design the current carrying conductor for EHV GIS, it is important to consider temperature-rise when rated current flows. In this paper, we analyze magnetic field distribution and power-loss, according to the change of materials when AC current flows into single-phase and three-phase bus bar, respectively. These results will be used as the basic design data when determining dimensions and materials for the current carrying conductor of EHV GIS.

  • PDF

열유동을 고려한 GIS 모선의 온도상승 예측 (Temperature Rise Prediction of GIS Bus Bar Considering Thermal Flow)

  • 김중경;오년호;이지연;한성진
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.742-747
    • /
    • 2009
  • Many works on the temperature distribution of power apparatus have usually done by coupled magneto-thermal analysis. Such a method can not consider the internal gas or oil flow in the power apparatus such as gas insulated switchgear, GIS bus bar, and power transformer. Moreover it can not show the internal temperature distribution of the power apparatus exactly. This paper proposes a coupled magneto-thermal-flow analysis considering Navier-Stokes equations. The convection heat transfer coefficient is calculated analytically by applying Nusselt number for natural convection and is applied to the boundary condition of proposed method. Temperature distribution of the GIS bus bar model considering thermal flow is obtained by the proposed method and shows good agreement with the experimental data.

GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템 (Data Acquisition System Applying TMO for GIS Preventive Diagnostic System)

  • 김태완;김윤관;장천현
    • 정보처리학회논문지A
    • /
    • 제16A권6호
    • /
    • pp.481-488
    • /
    • 2009
  • 가스절연개폐장치(Gas Insulated Switchgear:GIS)는 SF6가스를 절연 매체로 하는 대용량 전력 차단기기이다. GIS는 단순한 구조로 고장이 적고 신뢰성이 높은 편이지만 내부를 볼 수 없어 고장 확인이 어렵고 고장이 발생하면 파급 효과가 크고 복구가 어렵다. 따라서 GIS 내부의 이상 징후를 초기에 찾아낼 수 있도록 GIS 예방진단시스템이 도입되었다. GIS 예방진단시스템은 센서에서 수집, 분석한 정보로 이상 징후를 판 단하기 때문에 데이터의 신뢰성과 적시성이 중요하다. 하지만 기존 시스템은 중앙 집중 데이터 수집 방식으로 효율이 낮고 신뢰성과 적시성의 보장이 어렵다. 이러한 신뢰성과 적시성을 보장하기 위하여 GIS 예방진단시스템은 실시간성을 보장하는 미들웨어를 탑재해야 한다. 따라서 본 논문에서는 GIS 예방진단시스템의 신뢰성 향상을 위하여 실시간 분산 컴퓨팅의 적시성 보장을 위해 제안된 TMO를 적용한 미들웨어를 사용한 다. 그리고 TMO를 적용한 데이터 수집 및 감시, 제어 방법을 적용한 새로운 GIS 예방진단 시스템을 제안한다. 논문에서 제안하는 시스템은 TMO의 실시간 기능을 활용하여 데이터의 분산 처리가 가능한 통신제어장치를 개발하여 사용한다. 통신제어장치는 TMO를 통해 실시간 데이 터 수집 및 처리 과정의 적시성을 보장하고 데이터의 신뢰성을 높여 시스템의 성능 향상에 기여한다. 또한, 기존의 서버의 데이터 수집 및 처 리 과정을 통신제어장치가 부담하여 서버의 부하를 줄이고 향후 분산 환경을 지원할 수 있도록 설계하였다. 따라서 제안하는 시스템은 통신제 어장치의 적시성 보장을 통해 GIS 예방진단시스템의 신뢰성과 성능을 향상시키고 GIS의 안정적인 운영을 보장할 수 있다.

362 kV GIB 내에서 건조공기의 절연파괴 특성 (Breakdown Characteristics of Dry Air under 362 kV GIB)

  • 한기선;주형준;윤진열;유홍근
    • 한국전기전자재료학회논문지
    • /
    • 제23권10호
    • /
    • pp.804-808
    • /
    • 2010
  • In this paper, we studied the dielectric breakdown voltage characteristics by the AC withstand voltage test on using green insulation dry air instead of $SF_6$ insulation gas used in the GIB (gas insulated bus) of 362 kV GIS (gas insulated switchgear). The AC withstand voltage test applied to the standard KEPCO's 362 kV GIB with dry air insulation, and the equivalence of dielectric breakdown voltage for dry air and $SF_6$ gas were examined, and the empirical formulas of dielectric breakdown voltage for dry air were calculated, and the criterion of AC withstand voltage test for dry air insulation was derived. Using the criterion, dry air can be used instead of $SF_6$ gas for 362 kV GIB in the factory acceptance test was confirmed.

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Conducting Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1684-1686
    • /
    • 1998
  • Gas Insulated Switchgear(GIS) acts as an indispensible part in power transmission network. In order that GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, using the EHV test chamber, partial discharge quantity in GIS was measured when free conducting particles initiate to discharge for providing fundamental data for the purpose of developing predictive diagnosis technology on site GIS.

  • PDF