• Title/Summary/Keyword: Gas Hazard

Search Result 264, Processing Time 0.033 seconds

Thermal Hazards of Polystyrene Polymerization Process by Bulk Polymerization (벌크 중합법에 의한 폴리스티렌 중합공정의 열적위험성)

  • Han, In-Soo;Lee, Jung-Suk;Lee, Keun-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • The aim of this study is to assess thermal hazards of polystyrene polymerization process by bulk polymerization with accelerating rate calorimeter(ARC) and Multimax reactor system(MM). From this study, we found out that the polymerization process should be operated at reaction temperature of $120^{\circ}C{\sim}130^{\circ}C$. At reaction temperature over $130^{\circ}C$, there was a runaway reaction hazard due to the temperature control failure following a viscosity increase of reaction products. With a cooling failure of a reactor in the early stage of process operation at the reaction temperature ($120^{\circ}C{\sim}130^{\circ}C$), there was a high thermal hazard of burst of a reactor's rupture disk or explosion of a reactor caused by the rapid rise of temperature and pressure to $340^{\circ}C$, 5.3 bar respectively within 30 - 50 minutes.

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

International Research on Geotechnical Risk & Landslide Hazards (지반공학적 재해 및 산사태 위험도 분석에 관한 연구)

  • Yoon, Gil-Lim;Yoon, Yeo-Won;Kim, Hong-Yeon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.444-455
    • /
    • 2009
  • Great concerns on geotechnical risk & hazard assessment have been increased due to human and economic damage by natural disasters with recent global climate changes. In this paper, geotechnical problems in particular, landslides which is interested in European countries and North America, were mainly discussed. For these, 18 key topics on geotechnical risk and hazards which had been discussed at the LARAM 2008 workshop in Italy were analyzed after grouping by subjects. Main topic contents consisted of applications such as field measurement, early warning systems, uncertainty analysis of parameters using radar, optical data and statistical theory and so on. And the problems related to analysis of vulnerability and deformation due to earthquakes, investigation of gas zone using seismic reflection data in a landslide area, risk quantification and hazard assessment of landslide movements and multi-dimensional analysis for stability of complex slopes were attracted. Also, there were studies on risk matters of cultural heritage, the blockglide of clayey ground, simulations of debris flows based on GIS, quantification of the failure processes of rock slopes, a meshless method for 3D crack modelling, and finally risk assessment for cryological processes due to global warming.

  • PDF

Analysis of fire hazard of karaoke utilizing the fire simulation (화재시뮬레이션을 활용한 노래방 화재 위험성 분석)

  • Kim, Tae Kwon;Park, Jong Choel
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2533-2538
    • /
    • 2014
  • In this study, 2-zone model CFAST software was used to predict the fire hazard of karaoke. Model is a three-dimensional unsteady state. Accuracy of CFAST is verified by comparing result of CFAST analysis with result of real fire experiment. For analysis results, the oxygen concentration were reduced to 10% within 5 minutes in room 5, the carbon dioxide concentration were increased to 5%. Therefore, at the enclosed space like karaoke, we can predict that dangerous situation would occur and people be suffocated because of toxic gas.

A Study on the Explosionproof devices Installation in the Manufacturing Process (제조업체 방폭설비 적용에 관한 연구)

  • Song, Yong-Sig;Lee, Jun-Suk;Jeong, Hyun-Gyu;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.565-570
    • /
    • 2007
  • The explosionproof apparatus is a devices that is enclosed in a case capable of withstanding an explosion of a specified gas or vapor that may occur within it and of preventing the ignition of a specified gas or vapor surrounding the enclosure by sparks, flashes, or explosion of the gas or vapor within, and that operates at such an external temperature that a surrounding flammable atmosphere will not be ignited thereby This kind of exeplosionfproof devices should be installed suitable for the characteristics of the space or process condition that should be protected to prevent explosion or fire. But, due to the lack of information and techniques on the explosionproof technology, some dangerous area is not properly protected from an explosion or it cost too much to implement the explosionproof devices. In this report, the basic guidelines and several case studies of explosionproof devices installation will be introduced to be of help to field safety engineer.

  • PDF

A Case Study of Jet fire Estimation Model on the High Pressurized Pipeline of Natural Gas (고압가스배관의 제트화재 예측모델에 관한 사례연구)

  • Lee, Sang-Gon;Kim, Dong-Sung;Hwang, Cheol-Seung;Cho, Won-Cheol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.371-375
    • /
    • 2007
  • Due to the benefit of QRA(Quantitative Risk Analysis) method, we can evaluate the risk, and it helps us to make our safe. We also depend to some of correlation equations to assess the jet fire at high pressurized transmission line. However, we can evaluate the risk within limitations. After comparing the current model to investigation report of natural gas transmission line accident at EL-Paso in U.S., this study concludes that more research and study are required because currently developed model cannot expect factors of the fire risk such as flame configuration.

  • PDF

Investigation on Damage Effect Distance for High Pressure underground Flammable Gas Pipelines (지하매설 고압 가연성 가스 배관의 누출시나리오에 따른 피해 영향 거리)

  • Kim, Hyeyoung;Jung, Seungho
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.33-38
    • /
    • 2018
  • Defects in piping caused by corrosion or external impact of underground piping can lead to high risk of rupture of the piping due to high pressure. Flammable gas can be immediately ignited when discharged from piping, causing a jetfire. The damage of the radiant heat not only threatens the health of the workers who work in the industry but also the health of the people living in the neighboring residential areas. It is important to prevent and prepare before an accident occurs. In this study, three types of flammable gas underground piping accident scenarios were investigated, and the ranges of influence were determined using Phast ver7.2. and finally regression models were formulated to predict the ranges using excel and Matlab.

Safety Assessment for Hydrogen Gas Filling Facilities(One-Bank) (One-Bank 방식의 수소충전장치에 대한 정성적 안전성 평가)

  • Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.1
    • /
    • pp.95-100
    • /
    • 2012
  • This study is about the qualitative safety assessment for hydrogen gas filling facilities in Korea operating with one-bank type. The purpose of this safety assessment is about the development of components for design, fabrication, assembly, operability of dispenser and systems of the safety. For the qualitative safety assessment method, the study used FMEA(failure mode & effect analysis) and HAZOP(hazard & operability). This study evaluated the safety through FMEA and HAZOP then by referring to P&ID and PFD of hydrogen dispenser, thereby examining the dangerousness of the equipments, defects of the structure and problems of the operation.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

Risk Assessment for Performance Evaluation System of Hydrogen Refueling Station (수소충전소 성능평가 장비 안전성 평가 연구)

  • KANG, SEUNGKYU;LEE, DONGHOON
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.3
    • /
    • pp.232-239
    • /
    • 2022
  • This study performed qualitative and quantitative risk assessment of equipment for evaluating the protocol of hydrogen refueling stations and suggested measures to improve safety. Hazard and operability study was performed for qualitative risk assessment, and Hy-KoRAM was used for quantitative risk assessment. Through a qualitative risk assessment, additional ventilation devices were installed, simultaneous venting of the storage container was prohibited, and the number of repeated refilling of the evaluation equipment was identified to manage the number of fillings of the container. Through quantitative risk assessment, the area around the device was set as a restricted area when evaluating the station, and measures were suggested to reduce the frequency of accidents.