• Title/Summary/Keyword: Gas Gun

Search Result 452, Processing Time 0.023 seconds

A Study on the Assessment of Safety Performance for Complex Installation System of Stationary Fuel Cell and Boiler (건물용 연료전지-보일러 복합설치 안전성능 평가에 관한 연구)

  • Kim, Min-Woo;Lee, Eun-Kyung;Oh, Gun-Woo;Lee, Jung-Woon;Lee, Seung-Kuk
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.77-86
    • /
    • 2018
  • Interest in renewable energy is increasing for eco-friendly use of energy, and fuel cells are being used in various ways such as houses and buildings as power generation methods that have low emissions such as $NO_X$ and $CO_2$. As the supply of fuel cells expands, more and more boilers are installed in the existing buildings, but safety management is not being performed properly. Therefore, in this study, a prior study was conducted on the status of fuel cell-boiler complex installation and related criteria, and the risk factors were analyzed according to the installation environment and structure. Based on these standards, the safety performance of the fuel cell-boiler combined installation is assessed by conducting a demonstration using the starting product of the simulated operation to derive the installation criteria (proposal) for the fuel cell-boiler combined installation. The installation criteria (proposal) include the construction and connection method of the piping according to the fuel cell-boiler complex installation.

Synthesis of Highly Selective Polyimide Material and Comparison of Gas Permeability by Molecular Dynamics Study (고선택성 폴리이미드 소재의 합성 및 분자동력학 연구를 통한 기체투과도의 비교)

  • Lee, Jung Moo;Kim, Deuk Ju;Jeong, Moon Ki;Lee, Myung Gun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.162-170
    • /
    • 2015
  • In this study, gas permeability of polyimide materials having a various amine group was measured and molecular dynamics was used to analyze the dynamic characteristics of the gas molecules in the polyimide by calculating the position and velocity of the gas molecules with change of the time. The gas permeability of polyimide membrane having substitution site which increase free volume in the polymer was increased. However, polyimide with rigid structure showed decreased gas permeability. As a result of analyzing the change in the gas permeation behavior using molecular dynamics simulations, we confirmed that the results show the same tendency with actual measurements of the gas permeability.

Performance Test of a Single Pulse Gun for Transverse Pressure Wave Generation (횡단압력파 발생을 위한 단일 펄스건의 압력파 성능시험)

  • Lee, Jongkwon;Song, Wooseok;Koo, Jaye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.8
    • /
    • pp.599-606
    • /
    • 2019
  • The pulse gun device is designed to identify the transverse pressure wave propagation/damping mechanism into the combustion flow field and in the combustion chamber according to the arrangement of multiple injectors. The manufactured pulse gun was tested to verify operability at the target combustion pressure and control of the pressure wave intensity. Gas nitrogen was used to pressurize the high-pressure tube and an OHP film of $100{\mu}m$ thickness was used for the diaphragm. To check the speed and intensity of the pressure waves, the dynamic and static pressure were measured using the pressure transducer. The performance test confirmed that the manufactured pulse gun can generate pressure waves with transverse characteristics that can be controled for strength depending on the supply pressure.

Structure and properties of ion beam deposited diamond-like carbon films (이온빔 합성법에 의해 증착된 다이아몬드성 카본 필름의 구조 및 특성)

  • 김성화;이광렬;은광용
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.346-352
    • /
    • 1999
  • Diamond-like carbon (DLC) lims were deposited by using end hall type ion gun. Benzene gas was used for the generation of carbon ions. In order to systematically control the ion energy, we applied to the substrate DC, pulsed DC or 250 kHz medium frequency bias voltage, DLC films of superior mechanical properties of hardness 39$\pm$4 GPa and elastic mudulus 290$\pm$50GPa (2 to 6 times better than those of the films deposited by plasma assisted CVD method) could be obtained. Deposition rate was much higher than when using Kaufman type ion source, which results from higher ion beam current of end hall type ion gun. The mechanical properties and atomic bond structure were independent of the bias voltage type ion gun. The mechanical properties and atomic bond structure were independent of the bias voltage type but intimately related with the magnitude of the bias voltage. With increasing the negative bias voltage, the structure of the films changed to graphitic one resulting in decreased content of three dimensional inter-links. Degradation of the mechanical properties with increasing bias voltage could be thus understood in terms of the content odf three dimensional inter-links.

  • PDF

Optimization and Application of Si-DLC Coating with Low Friction and High Hardness Property by Using PECVD Method

  • Yeo, Gi-Ho;Mun, Jong-Cheol;Sin, Ui-Cheol;Lee, Hyeon-Seok;Choe, Sun-Ok;Yu, Jae-Mu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.169.2-169.2
    • /
    • 2013
  • 본 연구에서는 gas를 이용한 PECVD 공법중 이온화 에너지가 높고 대면적 코팅이 용이한 Hybrid 코팅 장비에서 Linear Ion-Gun 이용하여 탄화수소 계열의 gas인 $C_2H_2$ 와 Si을 함유한 TMS (tetramethylsilane, $Si(CH_3)_4)$ gas를 이용하여 저마찰, 고경도 특성을 갖는 Si-DLC 코팅에 대한 연구를 수행하였다. Si-DLC 코팅에 앞서 전처리 공정으로 Linear Ion-Gun에 Ar gas를 주입하고 고전압의 DC 전원을 인가하여 제품 표면의 건식세정 및 표면 활성화를 진행 후, $C_2H_2$ 와 TMS gas를 Linear Ion-Gun에 주입하여 Si-DLC 코팅 공정을 진행하였다. Si-DLC 코팅시 $C_2H_2$ gas 주입량을 고정하고 TMS 가스 유량을 5~20sccm으로 조절하여 Si 함유량에 따른 Si-DLC 코팅막의 특성을 분석하였다. 이렇게 코팅된 Si-DLC의 박막 특성 분석으로 마찰계수 측정을 위해 ball-on-disk 타입의 tribometer를 사용하였으며, 박막 경도 측정은 Nano-indenter를 이용하여 분석을 진행하였다. 그 결과 Si을 포함하지 않는 DLC의 경우 마찰계수가 ~0.2를 가지는 반면, Si-DLC의 경우 Si 함유량이 약 1.5at%일 때, 마찰계수 ~0.04 저마찰의 우수한 특성을 지니며, 박막의 경도는 22[Gpa]로 고경도의 Si-DLC 코팅을 확인할 수 있었다.

  • PDF

Effect of Igniter's Burning Rate on Negative Differential Pressure of Interior Ballistics (점화제 연소율이 강내탄도의 NDP에 미치는 영향)

  • Sung, Hyung-Gun;Jang, Jin-Sung;Yoo, Seung-Young;Oh, Seok-Hwan;Choi, Dong-Whan;Roh, Tae-Seong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.520-526
    • /
    • 2012
  • The appearance of the negative differential pressure(NDP), in which the shot base pressure is higher than the breech pressure, indicates that a potential damage on the gun system is increased. In order to safeguard the gun system, the igniter must be designed to minimize the NDP during the firing process. From this reason, the effect of igniter's burning rate on the NDP of the interior ballistics has been investigated through the numerical simulations. The NDP has been increased with increment of the coefficient in the burning rate of the igniter. A sudden change of the chamber pressure has been shown in case of using a singular coefficient.

  • PDF

Thermal Conductivity Properties of Building Insulation Materials with Freezing and thawing Cycles (동결융해 반복에 따른 건축용 단열재의 열전도 특성)

  • Lee, Gun-Cheol;Choi, Jung-Gu;Lee, Gun-Young;Lim, Sun-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.190-191
    • /
    • 2014
  • The building insulation materials shall keep their thermal conductivity constant even when the freezing and thawing repeats for over a long time. But, in this condition of repeated freezing and thawing, the organic building insulation material may suffer the degradation in the thermal performance as the gas put into the insulation materials gets out slowly over a long time. Accordingly, in this study, the change in the thermal performance has been tested and evaluated when the repeated freezing and thawing cycles happen.

  • PDF

Heat Transfer Characteristics During Gas Cooling Process of Carbon Dioxide in a Horizontal Tube (수평관내 초임계 영역의 Co2 냉각 열전달 특성)

  • Son, Chang-Hyo;Lee, Dong-Gun;Oh, Koo-Kyu;Jeong, Si-Young;Kim, Young-Lyoul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.289-295
    • /
    • 2004
  • The heat transfer coefficient and pressure drop during gas cooling process of carbon dioxide in a horizontal tube were investigated. The experiments were conducted without oil in the refrigerant loop. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flowmeter, an evaporator, and a gas cooler(test section). The main components of the water loop consist of a variable-speed pump, an isothermal tank, and a flowmeter. The gas cooler is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal stainless steel tube of the outer diameter of 9.53mm and of the inner diameter of 7.75mm. The length of the test section is 6m. The refrigerant mass fluxes were 200∼300kg/(m2$.$s) and the inlet pressure of the gas cooler varied from 7.5㎫ to 8.5㎫. The main results were summarized as follows : Pressure drop of CO2 increases with increasing gas cooler pressure. The friction factors of CO2 in a horizontal tube show a relatively good agreement with the correlation by Blasius. The heat transfer coefficient of CO2 in transcritical region increases with decreasing gas cooler pressure and decreasing mass flux of CO2. Most of correlations proposed in a transcritical region showed significant deviations with experimental data except for those predicted by Gnielinski.

Comparison on the Economical Efficiency of the Multiple Glazed Windows According to Life Cycle Costing of an Officetel Model Building (오피스텔 모델건물의 생애주기비용 분석에 의한 다층유리창 경제성 비교)

  • Jung Gun-Joo
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2006
  • The purpose of this study was to suggest ways on reducing the cooling and heating energy cost of the officetel building with the multiple glazing windows according to Life Cycle Costing. This study consisted of an hour-by hour energy simulation program and further data from the EnergyPlus V1-2-2 to the four pane type windows that were applied with 2 low-e polyester film and krypton gas to the officetel model building. It was determined that the four panes type windows that had 2 low-e polyester film and krypton gas applied to, them showed a cooling and heating cost reduction over traditional double glazed windows that were filled with air. According to this study, as well as the information from chart 4.5 and the LCC it was determined that the present value of the four panes of windows that had 2 low-e polyester film and krypton gas applied to them showed. a 11.4% reduction in heating and cooling in comparison to the traditional double glazed windows that were filled with air.

Growth and Properties of CrNx/TiNy/Al Based on N2 Gas Flow Rate for Solar Thermal Applications

  • Ju, Sang-Jun;Jang, Gun-Eik;Jang, Yeo-Won;Kim, Hyun-Hoo;Lee, Cheon
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.3
    • /
    • pp.146-149
    • /
    • 2016
  • The CrN/TiN/Al thin films for solar selective absorber were prepared by dc reactive magnetron sputtering with multi targets. The binary nitride CrN layer deposited with change in N2 gas flow rates. The gas mixture of Ar and N2 was an important parameter during sputtering deposition because the metal volume fraction (MVF) was controlled by the N2 gas flow rate. In this study, the crystallinity and surface properties of the CrN/TiN/Al thin films were estimated by X-ray diffraction (XRD), atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM). The composition and depth profile of thin films were investigated using Auger electron spectroscopy (AES). The absorptance and reflectance with wavelength spectrum were recorded by UV-Vis-NIR spectrophotometry at a range of 300~1,100 nm.