• Title/Summary/Keyword: Gas Explosion Accident

Search Result 184, Processing Time 0.027 seconds

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

A Study on Safety and Operational Management System for CNG Filling Stations (CNG충전소 안전.운영 관리를 위한 시스템 구축에 관한 연구)

  • Yang, Jae-Mo;Kim, Bum-Su;Yong, Jong-Won;Ko, Byung-Seok;Lee, Dong-Hyuk;Ko, Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.6
    • /
    • pp.8-13
    • /
    • 2011
  • All over the nation, a lot of industrial complex utilize gas as their energy source. Possibilities are fire, explosion, and leakage could happen any time in these large complexes. To prevent these tragic accidents and to minimize the damage when the accident occurs, the development of diagnostic technology for these facilities is imperative. The safety check is conducted on an individual and partial basis, currently. Accordingly, the accumulation and improvement of the safety management technology is necessary in order to make all the different checking techniques and management systems compatible, since checking processes, result interpretation techniques, and subsequent prognoses are not the same. The program provides damage scenarios from gas leakage. The output enables policy makers to predict the degree of infliction. Through this program, engineers are able to design an effective gas safety program to operate and maintain ubiquitous gas facilities.

A Study on Consequence Analysis of LNG/LPG/Gasoline Station (LNG/LPG/가솔린 Station의 사고피해영향평가 비교)

  • Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Ko, Euy-Seok;Lee, Gi-Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The advancement of industry have increased domestic energy demands and energy facilities such as storage facility, compressed gas pipe, station, and tank lorry. Also, concern about environment have diversified energy source to clean energy such as LNG. In these major energy facilities, major accident can happen to result in fire, explosion, toxic release and etc. In addition, it may cause chain accidents to the adjacent energy facilities. In this research, safety assessment was performed through the consequence analysis of LPG liquefied petroleum gas) station, gasoline station and LNG(liquiefied natural gas) station. The obtained result will be helpful to make a safety guideline of the LPG/LNG station built adjacent to the gasoline station.

  • PDF

Prediction of Damage Area due to Explosion of LNG-Hydrogen Mixed Gas (도시가스-수소 혼합가스의 누출사고 영향범위 분석)

  • Chan-sik, Yoon;Jin-du, Yang;Gil-soo, Na;Sung-Hyun, Im;Ki-young, Kim;Eun-ki, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.27-34
    • /
    • 2022
  • The government is promoting various policies to reduce greenhouse gas emissions for carbon neutrality, one of the key tasks is to revitalize the hydrogen economy. As one of these policies the government has formulated a plan to incorporate hydrogen into existing city gas pipes, and aims to commercialize 20% hydrogen mixing by 2026. In preparation for the commercialization of city gas and hydrogen mixture, this study quantitatively predicts the scale of damage and the range of impact in the event of leakage of these two gas mixtures. The quantitative damage prediction method is to calculate the damage conversion distance through the calculation of the TNT equivalent by setting the leakage amount of the gas mixture in the event of an accident under a virtual scenario.

Revision of related Regulations and Construction Standards for the Use of Information on Underground Facilities Quality Level (지하시설물 품질등급 정보의 활용을 위한 관련 규정 및 건설기준 개정 방안)

  • Park, Joon Kyu;Kim, Tae Hoon;Kim, Won Dae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • The computerization project for underground facilities in Korea began in earnest after the city gas explosion in Seoul in 1994, and the Daegu subway explosion in 1995. As such a large-scale gas explosion accident caused enormous economic loss including human casualties and potential benefits, the need for computerized for efficient management of underground facilities was greatly emphasized in society. Meantime, computerization of underground facilities has been carried out according to the basic plan for building national geographic information system. In this study, problems were identified based on the current status of construction and management of underground facility information, as well as laws and regulations, and directions for establishing quality standards were presented. In addition, construction work standards such as 「Public Survey Work Regulations」, design standards, standard specifications, and technical specifications, gas technology standards, design standards, and communication works so that underground facility information can be linked and utilized in construction work by examining the linkage of the underground facilities, the targets that can be used for quality level information on underground facilities were derived, and a proposal to revise the construction standards was presented. In the future, if the quality standards are established, it is expected that the accuracy and utilization in the construction field will be increased.

A Case Study on the TEMAZ Explosion Accident in Semiconductor Process (반도체 공정에서 TEMAZ폭발사고 사례연구)

  • Yang, Won-Baek;Rhim, Jong-Kuk;Hong, Seong-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.52-60
    • /
    • 2017
  • In diffusion process exhaust line during semiconductor manufacturing process, In order to improve the transportation efficiency in the piping by removing "The reaction by-product, $ZrO_2$ and The unreacted material, TEMAZ, TMA, $O_3$, etc" and "Powder being deposited", the piping temperature was raised to $80^{\circ}C$ or more by using the heater jacket, and the bellows at the rear end of the vacuum pump ruptured. So conducted a case study and try to prevent the similar accidents from occurring through case studies. The causes of the accident were analyzed as follows: the inflow of outside air due to the generation of a gap on the suction side of the vacuum pump and heating the pipe with the heater jacket resulted in the overpressure in the pipe due to the volumetric expansion of the gas generated by decomposition of the unreacted TEMAZ, It can be assumed that the most vulnerable bellows of the piping has been ruptured. In order to prevent such accidents, This study is aimed to identify the cause of pipeline rupture accident and to establish safety measures for the prevention of similar accidents by evaluating physical hazards of TEMAZ, which is assumed to be the cause of pipe rupture accident.

Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류 모니터링용 실시간 무선 원격 감시 시스템)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2729-2731
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. In this paper, results of development about Real-time Wireless Remote Monitoring System for Stray Current of Subway System are presented.

  • PDF

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The Development of Buried Type Reference Electrode Using Porous Ceramic(${\alpha}-Al_{2}O_{3}$) (다공성 세라믹(${\alpha}-Al_{2}O_{3}$)를 이용한 지중 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.145-147
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development of buried type reference electrode using porous ceramic$({\alpha}-Al_{2}O_{3})$ are presented.

  • PDF

Consequence Analysis of Toxic Gases Generated by Fire of Lithium Ion Batteries in Electric Vehicles (전기자동차 내 리튬이온전지 화재로 발생하는 독성가스의 위험성 분석)

  • Oh, Eui-young;Min, Dong Seok;Han, Ji Yun;Jung, Seungho;Kang, Tae-sun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 2019
  • As the market for portable electronic devices expands, the demand for Lithium Ion Battery (LIB) is also increasing. LIB has higher efficiency than other secondary batteries, but there is a risk of explosion / fire due to thermal runaway reaction. Especially, Electric Vehicles (EV) equipped with a large capacity LIB cell also has a danger due to a large amount of toxic gas generated by a fire. Therefore, it is necessary to analyze the risk of toxic gas generated by EV fire to minimize accident damage. In this study, the flow of toxic gas generated by EV fire was numerically analyzed using Computational Fluid Dynamic. Scenarios were established based on literature data and EV data to confirm the effect distance according to time and exposure standard. The purpose of this study is to analyze the risk of toxic gas caused by EV fire and to help minimize the loss of life and property caused by accidents.