• Title/Summary/Keyword: Gas Detection Sensor

Search Result 327, Processing Time 0.026 seconds

A Study on Fault Detection Monitoring and Diagnosis System of CNG Stations based on Principal Component Analysis(PCA) (주성분분석(PCA) 기법에 기반한 CNG 충전소의 이상감지 모니터링 및 진단 시스템 연구)

  • Lee, Kijun;Lee, Bong Woo;Choi, Dong-Hwang;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.3
    • /
    • pp.53-59
    • /
    • 2014
  • In this study, we suggest a system to build the monitoring model for compressed natural gas (CNG) stations, operated in only non-stationary modes, and perform the real-time monitoring and the abnormality diagnosis using principal component analysis (PCA) that is suitable for processing large amounts of multi-dimensional data among multivariate statistical analysis methods. We build the model by the calculation of the new characteristic variables, called as the major components, finding the factors representing the trend of process operation, or a combination of variables among 7 pressure sensor data and 5 temperature sensor data collected from a CNG station at every second. The real-time monitoring is performed reflecting the data of process operation measured in real-time against the built model. As a result of conducting the test of monitoring in order to improve the accuracy of the system and verification, all data in the normal operation were distinguished as normal. The cause of abnormality could be refined, when abnormality was detected successfully, by tracking the variables out of the score plot.

Characterization to flammable gas $\alpha$-$Fa_{2}O_{3}/SnO_{2}$ system thin film fabricated by APCVD (APCVD법에 위해 제조된 $\alpha$-$Fa_{2}O_{3}/SnO_{2}$계 박막의 가연성 가스 감지 특성 평가)

  • 심성은;이세훈;최성철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.10 no.2
    • /
    • pp.105-110
    • /
    • 2000
  • The $\alpha$-$Fa_{2}O_{3}/SnO_{2}$ thin film gas sensor was fabricated by APCVD and heat treated. The gas sensitivity to flammable gases ($CH_4$, $H_2$, LPG) was measured. This device was to heat treatment at $400^{\circ}C$, $450^{\circ}C$, $500^{\circ}C$, $550^{\circ}C$, $600^{\circ}C$ for 2 h to enhance the gas sensitivity. The heat treated device at $500^{\circ}C$ for 2 h had the best properties and especially it shows high sensitivity to H2 gas. The sensitivity to gases was studied in the temperature range from lOoC to $300^{\circ}C$ in order to find the optimum detection temperature. In the range of detection from 500 ppm to 10,000 ppm at $175^{\circ}C$ the fabricated device showed that the gas sensitivity to $H_2$ was from 62%~76% and to $CH_4$ was from 16 %~58% and to LPG was from 8%~37 %. The sensitivity difference between heat treated device and as fabricated one was about 10 8 The long-term stability to LPG at 1,000 ppm was converged to sensitivity of 30 %.

  • PDF

Nerve-Agent Selective Chemiresistors Fabricated by Oxime Decorated Polypyrrole Layer on Cellulose Paper (셀룰로오스 종이 상에 Oxime 도입된 polypyrrole 층을 제조한 신경작용제 선택적 화학저항 센서)

  • Changhoon Jeon;Taihwan Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.528-534
    • /
    • 2024
  • In continuous research of detecting highly toxic chemical warfare agents to ensure preparedness for the future battlefield, flexible and wearable sensor platforms with high sensitivity are still demanding. Herein we demonstrate a facile fabrication of polypyrrole-based chemiresistors on cellulose paper for the detection of nerve gas simulants. In order to optimize electrical properties of sensor platform, conducting polymer made of polypyrrole were first synthesized on flexible cellulose paper and interdigitated electrodes were formed thereon. Following confirmation of polypyrrole and/or oxime moiety through FT-IR analyses, electrical characteristics were measured in the various ratio of monomers between simple pyrrole and oxime-modified one. Typically for the optimized chemiresistor(2:8 molar ratio of simple pyrrole and oxime-modified one), eleven species of chemical warfare agents were examined and enhanced conductivity(104~105 order) was observed for three simulants(diethyl cyanophosphonate, diisopropyl fluorophosphonate and diethyl chlorophosphonate), which was mainly attributed to intermolecular hydrogen bonding, while no significant responses was recorded against sixteen common volatile organic chemicals.

Improved Vapor Recognition in Electronic Nose (E-Nose) System by Using the Time-Profile of Sensor Array Response (센서 응답의 Time-Profile 을 이용한 전자 후각 (E-Nose) 시스템의 Vapor 인식 성능 향상)

  • Yoon Seok, Yang
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.329-334
    • /
    • 2004
  • The electronic nose (E-nose) recently finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. The odor recognition performance of E-nose can be improved by manipulating the sensor array responses of vapors in time-profile forms. The different chemical interactions between the sensor materials and the volatile organic compounds (VOC's) leave unique marks in the signal profiles giving more information than collection of the conventional piecemal features, i.e., maximum sensitivity, signal slopes, rising time. In this study, to use them in vapor recognition task conveniently, a novel time-profile method was proposed, which is adopted from digital image pattern matching. The degrees of matching between 8 different vapors were evaluated by using the proposed method. The test vapors are measured by the silicon-based gas sensor array with 16 CB-polymer composites installed in membrane structure. The results by the proposed method showed clear discrimination of vapor species than by the conventional method.

Hydrogen Detection System Based on Pd Coated Single Mode Fiber Sensor (Pd이 코팅된 단일모드 광섬유 센서를 이용한 수소 검출 시스템)

  • Kim, Kwang-Taek;Park, Son-Oc;HwangBo, Seung;Mah, Jae-Pyung;Baik, Se-Jong;Im, Kie-Gon;Kim, Tae-Un;Kim, Hwe-Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.389-394
    • /
    • 2007
  • The characteristics of the single mode fiber hydrogen sensor have been investigated theoretically and experimentally. Palladium is adopted as a material for the transducer and a thin Ni film is used for the adhesion between the fiber end and the Pd film. It is shown that sensitivity and response time strongly depend on the thickness of Pd film. The single mode fiber sensor coated with 5 nm thick Ni adhesion layer and 10 nm thick Pd transducer layer showed 0.6 dB change of reflectivity and $3{\sim}5$ sec of response time as it absorbed 4% hydrogen gas.

Dynamic Rectangle Zone-based Collaboration Mechanism for Continuous Object Tracking in Wireless Sensor Networks (센서 네트워크에서 연속적인 개체 추적을 위한 동적 직사각형 영역 기반 협동 메커니즘)

  • Park, Bo-Mi;Lee, Eui-Sin;Kim, Tae-Hee;Park, Ho-Sung;Lee, Jeong-Cheol;Kim, Sang-Ha
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.8
    • /
    • pp.591-595
    • /
    • 2009
  • Most existing routing protocols for object detection and tracking in wireless sensor networks concentrate on finding ways to detect and track one and more individual objects, e.g. people, animals, and vehicles, but they do not be interested in detecting and tracking of continuous objects, e.g., poison gas and biochemical. Such continuous objects have quite different properties from the individual objects since the continuous objects are continuously distributed across a region and usually occupy a large area, Thus, the continuous objects could be detected by a number of sensor nodes so that sensing data are redundant and highly correlated. Therefore, an efficient data collection and report scheme for collecting and locally aggregating sensing data is needed, In this paper, we propose the Continuous Object Tracking Mechanism based on Dynamic Rectangle Zone for detecting, tracking, and monitoring the continuous objects taking into account their properties.

The Concentration Measurements of Toxic Exhaust Gas by Tunable Diode Laser Absorption Spectroscopy System (TDLAS 시스템을 이용한 유해 배기가스의 농도 계측)

  • Cha, Hak-Joo;Kim, Min-Soo;Shin, Myung-Chul;Kim, Se-Won;Chun, Kwang-Min
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.222-227
    • /
    • 2003
  • Recent advances in room-temperature, visible and near-IR diode laser sources for telecommunication, optical data storage applications are enabling combustion diagnostics system based on diode laser absorption spectroscopy. In contrast to some traditional sampling-based gas-sensing instruments, tunable diode laser absorption spectroscopy system is advantageous because of their non-invasive nature, high sensitivity, fast response time and real-time measurement capability. So, combined with fiber-optics and high sensitive detection strategies, compact and portable sensor system arc now appearing for a variety of applications. The objective of this research is to take advantage of distributed feed-back diode laser and measure the $CO_{2}$ concentration (by using direct absorption and wavelength modulation spectroscopy methods). In addition to survey spectra of $CO_{2}$ bands and spectroscopic parameters between 1565 and 1579 run were computed at temperatures between 296 and 1200 K (by using HITRAN 2000 database). It experimentally found out that the features of direct absorption and wavelength modulation spectroscopy methods.

  • PDF

Hydrogen Gas Sensing Characteristics of Pd-SiC Schottky Diode (Pd-SiC 쇼트키 다이오드의 수소 가스 감응 특성)

  • Kim, Chang-Kyo;Lee, Joo-Hun;Lee, Young-Hwan;Choi, Suk-Min;Cho, Nam-Ihn
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.448-453
    • /
    • 1999
  • A Pd-SiC Schottky diode for detection of hydrogen gas operating at high temperature was explored. Hydrogen-sensing behaviors of Pd-SiC Schottky diode were analyzed as a function of hydrogen concentration and temperature by I-V and ${\Delta}I$-t methods under steady-state and transient conditions. The effect of hydrogen adsorption on the barrier height was investigated. Analysis of the steady-state kinetics using I-V method confirmed that the atomistic hydrogen adsorption process is responsible for the barrier height change in the diode.

  • PDF

Wound-State Monitoring for Burn Patients Using E-Nose/SPME System

  • Byun, Hyung-Gi;Persaud, Krishna C.;Pisanelli, Anna Maria
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.440-446
    • /
    • 2010
  • Array-based gas sensors now offer the potential of a robust analytical approach to odor measurement for medical use. We are developing a fast reliable method for detection of microbial infection by monitoring the headspace from the infected wound. In this paper, we present initial results obtained from wound-state monitoring for burn patients using an electronic nose incorporating an automated solid-phase microextraction (SPME) desorption system to enable the system to be used for clinical validation. SPME preconcentration is used for sampling of the headspace air and the response of the sensor module to variable concentrations of volatiles emitted from SPME fiber is evaluated. Gas chromatography-mass spectrometry studies prove that living bacteria, the typical infectious agents in clinical practice, can be distinguished from each other by means of a limited set of key volatile products. Principal component analysis results give the first indication that infected patients may be distinguished from uninfected patients. Microbial laboratory analysis using clinical samples verifies the performance of the system.

Design, Fabrication, and Performance Evaluation of Showing Material for Early Expression of Fire Signs and Combined Inspection (화재징후 조기표출과 복합검사를 위한 표출재 설계, 제작 및 성능 평가)

  • Dongcheol Shin;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.187-193
    • /
    • 2023
  • Previous research has explored early expression of fire signs before the burning of insulation. To achieve this, typically, automatic inspections are used to detect gas emitted from odor capsules at electrical connection points; additionally, early fire signs can be expressed using visual inspection of changes in the appearance of temperature caps. However, early detection of electrical fire is often difficult because only specific inspections, which are not complex, are performed. Therefore, in this paper, we present complex inspection techniques, such as visual inspection, odor inspection, and automatic inspection, and propose a showing material of fire signs that can solve conventional problems. In addition, this study examines the conditions under which the candidate material for the showing material is designed, the composition of the candidate material selected based on the designed conditions, the manufacturing means used to produce the showing material considering the temperature for early expression of fire signs, and the performance of the produced showing material. Furthermore, we analyze various effects that can occur through the proposed display material.