• 제목/요약/키워드: Gamma-ray spectra

검색결과 127건 처리시간 0.029초

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

Mössbauer Study of the Dynamics in BaFe12O19 Single Crystals

  • Choi, J.W.;Sur, J.C.;Lim, Jung-Tae;Kim, Chin-Mo;Kim, Chul-Sung
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.6-8
    • /
    • 2012
  • M$\ddot{o}$ssbauer spectra of hexagonal $BaFe_{12}O_{19}$ single crystals were studied at various temperatures (4-300 K). It was found that the spin states in Fe atoms were parallel to the ${\gamma}$-ray's direction into a single crystal along the caxis. The location of the Fe ion in the 2b site is unusual in an oxide structure and has strong anisotropic lattice vibrations. Moreover, at room temperature, the zero absorption lines of the Fe ions at the 2b site were observed due to fast diffusion motion in a double well atomic potential. The two Fe ions of the single crystal mainly enter into the sites in the mirror plane of the trigonalbipyramidal structure.

사인파속도형 Mossbauer 분광계의 속도눈금 매기기와 Magnetite의 Mossbauer 분광법에 의한 연구 (Velocity Calibration of Sinusoidal Mode for Mossbauer Spectrometer and Mossbauer Study on $Fe_3O_4$)

  • 이충섭;이찬영
    • 한국자기학회지
    • /
    • 제7권5호
    • /
    • pp.232-236
    • /
    • 1997
  • Mossbauer 분광계의 사인파속도 Mode에서 Fe-foil을 사용한 속도눈금매기기를 상세하게 소개하였다. 사인 파속도형 Mossbauer 분광계의 장점은 스프링의 자연진동에 의한 것으로 속도가 안정됨과 정밀함에 있다. Fe$_{3}$O$_{4}$와 U-Fe$_{3}$O$_{4}$(unbalanced Fe$_{3}$O$_{4}$)의 Mossbauer 스펙트럼을 분석하여 사인파속도 mode에서의 성능을 평가하였다.

  • PDF

방사선조사에 따른 저밀도 폴리에틸렌의 유전특성 (Dielectric Properties on Gamma Ray Irradiated Low Density Polyethylene)

  • 김기엽;류부형;강성화;이청;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제13권11호
    • /
    • pp.938-942
    • /
    • 2000
  • Radiation effects on dielectric properties of low density polyethylene(LDPE) were investigated using the various measurements of FT-IR, gel content and elongation at break. FT-IR spectra showed that polar groups were comprised in LDPE due to radiation treatment. It was also confirmed that the formation of polar groups on LDPE caused the increased dielectric properties such as permittivity and tan $\delta$. However, in this study, any evidence of decreasing permittivity was not found although the morphological change of LDPE could be identified from the increasing gel content and the decreasing elongation.

  • PDF

Interferometric Monitoring of Gamma-ray Bright AGNs:Measuring the Magnetic Field Strength of 4C+29.45

  • Kang, Sincheol;Lee, Sang-Sung;Hodgson, Jeffrey;Algaba, Juan-Carlos;Lee, Jee Won;Kim, Jae-Young;Park, Jongho;Kino, Motoki;Kim, Daewon;Trippe, Sascha
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.52.1-52.1
    • /
    • 2021
  • We present the results of multi-epoch, multi-frequency monitoring of a blazar 4C +29.45, which was regularly monitored as part of the Interferometric Monitoring of GAmma-ray Bright AGNs program - a key science program of the Korean Very long baseline interferometry Network (KVN). Observations were conducted simultaneously at 22, 43, 86 and 129 GHz during the 4 years from December 2012 to December 2016. We also used additional data from the 15 GHz Owens Valley Radio Observatory (OVRO) monitoring program. From the 15 GHz light curve, we estimated the variability time scales of the source during several radio flux enhancements. We found that the source experiencesd 6 radio flux enhancements with variability time scales of 9-187 days during the observing period, yielding corresponding variability Doppler factors of 9-27. From the multi-frequency simultaneous KVN observations, we were able to obtain accurate radio spectra of the source and hence to more precisely measure the turnover frequencies 𝜈r of synchrotron self-absorbed (SSA) emission with a mean value of ${\bar{\nu}_r}=28.9GHz$. Using jet geometry assumptions, we estimated the size of the emitting region at the turnover frequency. Taking into account these results, we found that the equipartition magnetic field strength is up to two orders of magnitudes higher than the SSA magnetic field strength (0.6-99 mG). This is consistent with the source being particle dominated.

  • PDF

Hot Wall Epitaxy(HWE) 법에 의해 성장된 $AgGaSe_2$ 단결정 박막의 광전류 온도 의존성 (Temperature dependence of photocurrent spectra for $AgGaSe_2$ single crystal thin film grown by hot wall epitaxy)

  • 홍광준;방진주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.179-180
    • /
    • 2007
  • Single crystal $AgGaSe_2$ layers were grown on thoroughly etched semi-insulating GaAs(100) substrate at $420^{\circ}C$ with hot wall epitaxy (HWE) system by evaporating $AgGaSe_2$ source at $630^{\circ}C$. The crystalline structure of the single crystal thin films was investigated by the photoluminescence and double crystal X-ray diffraction (DCXD). The carrier density and mobility of single crystal $AgGaSe_2$ thin films measured with Hall effect by van der Pauw method are $4.05{\times}\;10^{16}/cm^3$, $139\;cm^2/V{\cdot}s$ at 293 K. respectively. The temperature dependence of the energy band gap of the $AgGaSe_2$ obtained from the absorption spectra was well described by the Varshni's relation, $E_g(T)=1.9501\;eV\;-\;(8.79{\times}10^{-4}\;eV/K)T^2$/(T + 250 K). The crystal field and the spin-orbit splitting energies for the valence band of the $AgGaSe_2$ have been estimated to be 0.3132 eV and 0.3725 eV at 10 K, respectively, by means of the phcitocurrent spectra and the Hopfield quasicubic model. These results indicate that the splitting of the ${\Delta}So$ definitely exists in the $\Gamma_5$ states of the valence band of the $AgGaSe_2$. The three photocurrent peaks observed at 10 K are ascribed to the $A_1$-, $B_1$-, and $C_1$-exciton peaks for n = 1.

  • PDF

Measuring and unfolding fast neutron spectra using solution-grown trans-stilbene scintillation detector

  • Nguyen Duy Quang;HongJoo Kim;Phan Quoc Vuong;Nguyen Duc Ton;Uk-Won Nam;Won-Kee Park;JongDae Sohn;Young-Jun Choi;SungHwan Kim;SukWon Youn;Sung-Joon Ye
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1021-1030
    • /
    • 2023
  • We propose an overall procedure for measuring and unfolding fast neutron spectra using a trans-stilbene scintillation detector. Detector characterization was described, including the information on energy calibration, detector resolution, and nonproportionality response. The digital charge comparison method was used for the investigation of neutron-gamma Pulse Shape Discrimination (PSD). A pair of values of 600 ns pulse width and 24 ns delay time was found as the optimized conditions for PSD. A fitting technique was introduced to increase the trans-stilbene Proton Response Function (PRF) by 28% based on comparison of the simulated and experimental electron-equivalent distributions by the Cf-252 source. The detector response matrix was constructed by Monte-Carlo simulation and the spectrum unfolding was implemented using the iterative Bayesian method. The unfolding of simulated and measured spectra of Cf-252 and AmBe neutron sources indicates reliable, stable and no-bias results. The unfolding technique was also validated by the measured cosmic-ray induced neutron flux. Our approach is promising for fast neutron detection and spectroscopy.

Pulse pileup correction method for gamma-ray spectroscopy in high radiation fields

  • Lee, Minju;Lee, Daehee;Ko, Eunbie;Park, Kyeongjin;Kim, Junhyuk;Ko, Kilyoung;Sharma, Manish;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.1029-1035
    • /
    • 2020
  • The detector suffers from pulse pileup by overlapping of the signals when it was used in high radiation fields. The pulse pileup deteriorates the energy spectrum and causes count losses due to random co-incidences, which might not resolve within the resolving time of the detection system. In this study, it is aimed to propose a new pulse pileup correction method. The proposed method is to correct the start point of the pileup pulse. The parameters are obtained from the fitted exponential curve using the peak point of the previous pulse and the start point of the pileup pulse. The amplitude at the corrected start point of the pileup pulse can be estimated by the peak time of the pileup pulse. The system is composed of a NaI (Tl) scintillation crystal, a photomultiplier tube, and an oscilloscope. A 61 μCi 137Cs check-source was placed at a distance of 3 cm, 5 cm, and 10 cm, respectively. The gamma energy spectra for the radioisotope of 137Cs were obtained to verify the proposed method. As a result, the correction of the pulse pileup through the proposed method shows a remarkable improvement of FWHM at 662 keV by 29, 39, and 7%, respectively.

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

Calibration of TEPC for CubeSat Experiment to Measure Space Radiation

  • Nam, Uk-Won;Park, Won-Kee;Lee, Jaejin;Pyo, Jeonghyun;Moon, Bong-Kon;Lee, Dae-Hee;Kim, Sunghwan;Jin, Ho;Lee, Seongwhan;Kim, Jungho;Kitamura, Hisashi;Uchihori, Yukio
    • Journal of Astronomy and Space Sciences
    • /
    • 제32권2호
    • /
    • pp.145-149
    • /
    • 2015
  • A newly designed Tissue Equivalent Proportional Counter (TEPC) has been developed for the CubeSat mission, SIGMA (Scientific cubesat with Instruments for Global Magnetic field and rAdiation) to investigate space radiation. In order to test the performance of the TEPC, we have performed heavy ion beam experiments with the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. In space, human cells can be exposed to complex radiation sources, such as X-ray, Gamma ray, energetic electrons, protons, neutrons and heavy charged particles in a huge range of energies. These generate much a larger range of Linear Energy Transfer (LET) than on the ground and cause unexpected effects on human cells. In order to measure a large range of LET, from 0.3 to $1,000keV/{\mu}m$, we developed a compact TEPC which measures ionized particles produced by collisions between radiation sources and tissue equivalent materials in the detector. By measuring LET spectra, we can easily derive the equivalent dose from the complicated space radiation field. In this HIMAC experiment, we successfully obtained the linearity response for the TEPC with Fe 500 MeV/u and C 290 MeV/u beams and demonstrated the performance of the active radiation detector.