• Title/Summary/Keyword: Gamma source

Search Result 668, Processing Time 0.025 seconds

Effect of Codonopsis lanceolatae Extracts on Mouse IL-2, IFN-${\gamma}$, IL-10 Cytokine Production by Peritoneal Macrophage and the Ratio of IFN-${\gamma}$, IL-10 Cytokine (더덕 추출물의 경구 투여가 마우스의 사이토카인 생성과 IFN-${\gamma}$, IL-10 Ratio에 미치는 영향)

  • Ryu, Hye-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.1
    • /
    • pp.69-74
    • /
    • 2009
  • Codonopsis lanceolatae have been used as one of the traditional remedies as well as food source. We previously reported that in vitro supplementation of Codonopsis lanceolatae water extracts enhanced the splenocytes proliferation compared to the control group. This study, the combined immunomodulative effect of water extract Codonopsis lanceolatae was Seven to eight weeks old mice(balb/c) was fed ad libitum on chow diet and water extract of Codonopsis lanceolatae was orally administrated every other day for four weeks at two different concentrations(50 and 500 mg/kg B.W.). The production of cytokine(IL-2, IL-10 and IFN-${\gamma}$), secreted by macrophages stimulated with LPS or not, were detected by ELISA assay using the cytokine kit. The result of ex vivo study showed that the IL-2, IL-10 and IFN-${\gamma}$ was detected at 500 mg/kg B.W. supplementation group with LPS stimulation in all cases. Also, ratio of IFN-${\gamma}$, IL-10 was the range of 3${\sim}$7 with mitogen stimulation such as Con A and LPS. In conclusion, this study suggests that Codonopsis lanceolatae extracts may enhance the immune function by regulating the cytokine(IL-2, IL-10 and IFN-${\gamma}$) prodution capacity by activated macrophages in mice.

Effect of Electron Beam and ${\gamma}$-Ray Irradiation on the Curing of Epoxy Resin

  • Kang, Phil-Hyun;Park, Jong-Seok;Nho, Young-Chang
    • Macromolecular Research
    • /
    • v.10 no.6
    • /
    • pp.332-338
    • /
    • 2002
  • The effect of an electron beam and ${\gamma}$-ray irradiation on the curing of epoxy resins was investigated. Diglycidyl ether of bisphenol A (DGEBA) and diglycidyl ether of bisphenol F (DGEBF) as epoxy resin were used. The epoxy resins containing 1.0-3.() wt% of triarylsulphonium hexafluoroantimonate(TASHFA) and triarylsulphonium hexafluorophosphate(TASHFP) as initiator were irradiated under nitrogen at room temperature with different dosage of EB and ${\gamma}$-rays from a Co$^{60}$ u source. The chemical and mechanical characteristics of irradiated epoxy resins were compared after curing of EB and ${\gamma}$-ray irradiation. The thermal properties of cured epoxy were investigated using dynamic mechanical thermal analysis. The chemical structures of cured epoxy were characterized using near infrared spectroscopy. Mechanical properties such as flexural strength, modulus were measured. The gel fraction of DGEBA with ${\gamma}$-ray was higher than that of the epoxy with EB at the same dose. Young's modulus of the sample irradiated by ${\gamma}$-ray is higher than that of sample cured by EB. From the result of strain at yield, it was found that the epoxy cured by ${\gamma}$-ray had a higher stiff property compared with the irradiated by EB.

The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera (감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가)

  • Yu, A-Ram;Lee, Young-Sub;Kim, Jin-Su;Kim, Kyeong-Min;Cheon, Gi-Jeong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.216-224
    • /
    • 2009
  • $^{131}I$ is a radiological isotope being used widely for treatment of cancer as emitting gamma-ray and it is also applied to estimate the function of thyroid for its accumulation in thyroid. However, $^{131}I$ is more difficult to quantitate comapred to $^{99m}Tc$, because $^{131}I$ has multiple energy gamma-ray emissions compared to $^{99m}Tc$ which is a mono energetic gamma-ray source. Especially, scattered ray and septal penetration resulted by high energy gamma ray have a bad influence upon nuclear medicine image. The purpose of this study was to estimate scatter components depending on the different source locations within a phantom using Monte Carlo simulation (GATE). The simulation results were validated by comparing with the results of real experiments. Dual-head gamma camera (ECAM, Chicago, Illinois Siemens) with high energy, general-purpose, and parallel hole collimators (hole radius: 0.17 cm, septal thickness: 0.2 cm, length: 5.08 cm) was used in this experiment. The NaI crystal is $44.5{\times}59.1\;cm$ in height and width and 0.95 cm in thickness. The diameter and height of PMMA phantom were 16 cm and 15 cm, respectively. The images were acquired at 5 different locations of $^{131}I$ point source within the phantom and the images of $^{99m}Tc$ were also acquired for comparison purpose with low energy source. The simulation results indicated that the scattering was influenced by the location of source within a phantom. The scattering effects showed the same tendency in both simulation and actual experiment, and the results showed that the simulation was very adequate for further studies. The results supported that the simulation techniques may be used to generalize the scattering effects as a function of a point source location within a phantom.

  • PDF

Effect of Corn Extracts on Mouse IL-2 Cytokine Production by Peritoneal Macrophage and the Ratio of IFN-${\gamma}$, IL-10 Cytokine (옥수수 추출물의 경구 투여가 사이토카인 IL-2 생성과 IFN-${\gamma}$와 IL-10 Ratio에 미치는 영향)

  • Ryu, Hye-Sook
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.2
    • /
    • pp.362-367
    • /
    • 2012
  • Corn has been used for a long time as a traditional remedy, as well as a food source. We previously reported that in vitro supplementation of corn water extracts enhanced the proliferation of splenocytes, compared to the control group. In this study, we examined the immunomodulative effect of a water extract of corn. Seven to eight weeks old mice(Balb/c) were fed an ad libitum chow diet, and were orally administrated a water extract of corn every other day, for four weeks, at two different concentrations(50 and 500 mg/kg B.W). Cytokine production(IL-2, IL-10 and IFN-${\gamma}$) by macrophages stimulated with LPS or not stimulated with LPS was detected by ELISA assay using the cytokine kit. In an ex vivo study, the cytokines IL-2, IL-10 and IFN-${\gamma}$ were detected at 500 mg/kg b.w. supplementation group with LPS stimulation in all cases. Also, the ratio of IFN-${\gamma}$ to IL-10 was in the range of 0~3 with mitogen stimulation, such as con A and LPS. In conclusion, this study suggests that in mice, corn extracts may enhance immune function by regulating the cytokine production(IL-2, IL-10 and IFN-${\gamma}$) of the activated macrophages.

Spatial resolution and natural image quality assessment evaluation of gamma camera image using pinhole collimator in lutetium-yttrium oxyorthosilicate scintillation detector

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2567-2571
    • /
    • 2023
  • Scintillator materials are widely used in the medical and industrial fields for imaging systems using gamma cameras. In this study, image evaluation is performed by modeling a gamma camera system based on a lutetium-yttrium oxyorthosilicate (LYSO) scintillation detector using a pinhole collimator that can improve the spatial resolution. A LYSO detector-based gamma camera system is modeled using a Monte Carlo simulation tool. The geometric concept of the pinhole collimator is designed using various magnification factors, and the spatial resolution is measured using the acquired source image. To evaluate the resolution, the full width at half maximum (FWHM) and natural image quality assessment (NIQE), a no-reference-based parameter, are used. We confirm that the FWHM and NIQE values decrease simultaneously when the diameter of the pinhole collimator increases. Additionally, we confirm that the spatial resolution improves as the magnification factor increases under the same pinhole diameter condition. Particularly, a 0.57 mm FWHM value is obtained using the modeled gamma camera system with a LYSO scintillation detector. In conclusion, our results demonstrate that a pinhole collimator with a LYSO scintillation detector is a promising gamma camera imaging system.

Development of a multi-modal imaging system for single-gamma and fluorescence fusion images

  • Young Been Han;Seong Jong Hong;Ho-Young Lee;Seong Hyun Song
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3844-3853
    • /
    • 2023
  • Although radiation and chemotherapy methods for cancer therapy have advanced significantly, surgical resection is still recommended for most cancers. Therefore, intraoperative imaging studies have emerged as a surgical tool for identifying tumor margins. Intraoperative imaging has been examined using conventional imaging devices, such as optical near-infrared probes, gamma probes, and ultrasound devices. However, each modality has its limitations, such as depth penetration and spatial resolution. To overcome these limitations, hybrid imaging modalities and tracer studies are being developed. In a previous study, a multi-modal laparoscope with silicon photo-multiplier (SiPM)-based gamma detection acquired a 1 s interval gamma image. However, improvements in the near-infrared fluorophore (NIRF) signal intensity and gamma image central defects are needed to further evaluate the usefulness of multi-modal systems. In this study, an attempt was made to change the NIRF image acquisition method and the SiPM-based gamma detector to improve the source detection ability and reduce the image acquisition time. The performance of the multi-modal system using a complementary metal oxide semiconductor and modified SiPM gamma detector was evaluated in a phantom test. In future studies, a multi-modal system will be further optimized for pilot preclinical studies.

Influences of Culture Medium Components on the Production Poly (γ-Glutamic Acid) by Bacillus subtilis GS-2 Isolated Chungkookjang (청국장에서 분리한 Bacillus subtilis GS-2에 의한 Poly(γ-Glutamic Acid) 생산의 최적 배양조건)

  • Bang, Byung-Ho;Rhee, Moon-Soo;Kim, Kwan-Pil;Yi, Dong-Heui
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.3
    • /
    • pp.677-684
    • /
    • 2012
  • A bacterium strain GS-2 isolated from the Korean traditional seasoning food, Chungkookjang and was determined to produce large amounts of ${\gamma}$-PGA with high productivity when provided with simple nutrients (L-glutamic acid 2.0%, glucose 1.0%, $NH_4Cl$ 0.5%, $KH_2PO_4$ 0.05%, $MgSO_4{\cdot}7H_2O$ 0.01%, pH 7.0). In this study, the culture medium for this strain was optimized for the production of ${\gamma}$-PGA. The Bacillus subtilis GS-2 required supplementation with L-glutamic acid and other nutrients for maximal production of ${\gamma}$-PGA. The optimal culture conditions for ${\gamma}$-PGA production were a 48 hr culture time, a temperature of $33^{\circ}C$ and initial pH of 6.5 by rotary shaking (220 rpm). A maximum ${\gamma}$-PGA production of 31.0 $g/{\ell}$ was obtained with L-glutamic acid (30 $g/{\ell}$), sucrose (the main carbon source, 30 $g/{\ell}$), $NH_4Cl$ (the main nitrogen source, 2.5 $g/{\ell}$), $KH_2PO_4$ (1.5 $g/{\ell}$) and $MgSO_4{\cdot}7H_2O$ (0.15 $g/{\ell}$) in the culture medium.

Elemental Analysis by Neutron Induced Nuclear Reaction - Prompt Gamma Neutron Activation Analysis for Chemical Measurement - (중성자 핵반응을 이용한 원소 검출기술 - 즉발감마선 중성자 방사화분석법을 이용한 검출기술 -)

  • Song, Byung Chul;Park, Yong Joon;Jee, Kwang Yong
    • Analytical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.1041-1051
    • /
    • 2003
  • Neutron induced prompt gamma activation analysis (PGAA) offers a nondestructive, sensitive and relatively rapid method for the determination of trace and major elements and is proven to be convenient for online analysis of minerals, metals, coal, cement, petrochemical, coating, paper as well as many other materials and products. The technique has found many uses in medicine, industry, research, security and the detection of contraband items. This report reviews the present status and future trends of the PGAA techniques. Requirements for the system are neutron source, high resolution HPGe detectors with a high-voltage power supply, an amplifier, analog-to-digital converter, and a multichannel analyzer for the detection and measurement of prompt ${\gamma}$-ray emit form the neutron capture elements. Introducing a ${\gamma}$-${\gamma}$ coincidence system also improves the quality of the ${\gamma}$-ray spectrum by suppressing the background created from the Compton scattering of high energy prompt ${\gamma}$-rays. A PGAA system using a $^{252}Cf$ neutron source is currently under construction for the on-line measurement of several elements in aqueous samples at KAERI. The system can be applied for the detection of chemical weapons and explosives as well as various narcotics.

Characterization of a CLYC Detector and Validation of the Monte Carlo Simulation by Measurement Experiments

  • Kim, Hyun Suk;Smith, Martin B.;Koslowsky, Martin R.;Kwak, Sung-Woo;Ye, Sung-Joon;Kim, Geehyun
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.1
    • /
    • pp.48-55
    • /
    • 2017
  • Background: Simultaneous detection of neutrons and gamma rays have become much more practicable, by taking advantage of good gamma-ray discrimination properties using pulse shape discrimination (PSD) technique. Recently, we introduced a commercial CLYC system in Korea, and performed an initial characterization and simulation studies for the CLYC detector system to provide references for the future implementation of the dual-mode scintillator system in various studies and applications. Materials and Methods: We evaluated a CLYC detector with 95% $^6Li$ enrichment using various gamma-ray sources and a $^{252}Cf$ neutron source, with validation of our Monte Carlo simulation results via measurement experiments. Absolute full-energy peak efficiency values were calculated for gamma-ray sources and neutron source using MCNP6 and compared with measurement experiments of the calibration sources. In addition, behavioral characteristics of neutrons were validated by comparing simulations and experiments on neutron moderation with various polyethylene (PE) moderator thicknesses. Results and Discussion: Both results showed good agreements in overall characteristics of the gamma and neutron detection efficiencies, with consistent ~20% discrepancy. Furthermore, moderation of neutrons emitted from $^{252}Cf$ showed similarities between the simulation and the experiment, in terms of their relative ratios depending on the thickness of the PE moderator. Conclusion: A CLYC detector system was characterized for its energy resolution and detection efficiency, and Monte Carlo simulations on the detector system was validated experimentally. Validation of the simulation results in overall trend of the CLYC detector behavior will provide the fundamental basis and validity of follow-up Monte Carlo simulation studies for the development of our dual-particle imager using a rotational modulation collimator.

Real-time wireless marine radioactivity monitoring system using a SiPM-based mobile gamma spectroscopy mounted on an unmanned marine vehicle

  • Min Sun Lee;Soo Mee Kim;Mee Jang;Hyemi Cha;Jung-Min Seo;Seungjae Baek;Jong-Myoung Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2158-2165
    • /
    • 2023
  • Marine radioactivity monitoring is critical for taking immediate action in case of unexpected nuclear accidents at nuclear facilities located near coastal areas. Especially when the level of contamination is not predictable, mobile monitoring systems will be useful for wide-area ocean radiation survey and for determination of the level of radioactivity. Here, we used a silicon photomultiplier and a high-efficiency GAGG crystal to fabricate a compact, battery-powered gamma spectroscopy that can be used in an ocean environment. The developed spectroscopy has compact dimensions of 6.5 × 6.5× 8 cm3 and weighs 560 g. We used LoRa, a low-power wireless protocol for communication. Successful data transmission was achieved within 1.4 m water depth. The developed gamma spectroscopy was able to detect radioactivity from a 137Cs point source (3.7 kBq) at a distance of 20 cm in water. Moreover, we demonstrated an unmanned radioactivity monitoring system in a real sea by combining unmanned surface vehicle with the developed gamma spectroscopy. A hidden 137Cs source (3.07 MBq) was detected by the unmanned system at a distance of 3 m. After successfully testing the developed mobile spectroscopy in an ocean environment, we believe that our proposed system will be an effective solution for mobile real-time marine radioactivity monitoring.