• 제목/요약/키워드: Gamma radiation detection

검색결과 192건 처리시간 0.029초

Advances in gamma radiation detection systems for emergency radiation monitoring

  • Kumar, K.A. Pradeep;Sundaram, G.A. Shanmugha;Sharma, B.K.;Venkatesh, S.;Thiruvengadathan, R.
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2151-2161
    • /
    • 2020
  • The study presents a review of research advancements in the field of gamma radiation detection systems for emergency radiation monitoring, particularly two major sub-systems namely (i) the radiation detector and (ii) the detection platform - air-borne and ground-based. The dynamics and functional characteristics of modern radiation detector active materials are summarized and discussed. The capabilities of both ground-based and aerial vehicle platforms employed in gamma radiation monitoring are deliberated in depth.

자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계 (Design of radiation detection circuit for gamma column scanning)

  • 김종범;정성희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF

영상처리기반 감마선원 거리탐지 고속화 및 가시화 연구 (The Visualization and the Fast Detection of Gamma Radiation Source using Stereo Image Processing)

  • 황영관;이남호
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.2001-2006
    • /
    • 2016
  • 감마선 공간 탐지 장치는 감마선원을 스캔하여 영상화 한 후 스테레오 영상처리기술을 적용하여 탐지선원까지의 거리를 측정한다. 또한 실제 공간의 방사선원에 대한 분포 정보를 제공해 준다. 본 논문에서는 감마선 탐지장치가 3차원 공간상에서 장치로부터 선원을 찾기 위해 스캔하는 탐지 시간을 단축 시킬 수 있도록 감마선 탐지 고속화 알고리즘을 구현하였다. 그리고 감마선 조사 시험장에서 실험을 통해 그 성능을 검증하였다. 탐지시험 결과 고속 탐지를 위한 알고리즘을 적용할 경우 단일선원을 탐지할 경우 좌 우 스테레오 영상 획득 시보다 약 35% 의 탐지 시간을 단축시킬 수 있음을 확인하였다. 또한 사용자에게 방사선 공간분포 정보를 효율적으로 전달하기 위한 감마선원 분포의 입체 가시화를 구현하여 방사선원에 대한 정보를 제공할 수 있도록 하였다.

PSL과 ESR 분석에 의한 건조수산물의 방사선 조사 여부 판별 특성 연구 (Detection Properties of Irradiated Dried Seafoods Using PSL and ESR)

  • 송범석;한인준;윤영민;최수정;김재경;박종흠;정일윤;이주운;김병근;김규헌;김재훈
    • 방사선산업학회지
    • /
    • 제6권2호
    • /
    • pp.119-123
    • /
    • 2012
  • The detection properties of gamma-irradiated (0~10 kGy) dried seaweed, dried shrimp, and seasoned dried filefish were investigated by photo-stimulated luminescence (PSL) and electron spin resonance (ESR). PSL could be used as a detection method on irradiated dried seaweed and dried shrimp as they showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples with doses above l kGy. However, PSL could not be applied to detect irradiated seasoned dried filefish, because gamma-irradiated sample at 10 kGy even yielded photon counts less than 700 counts/60 s (negative). The ESR spectroscopy for only dried shrimp revealed specific signals derived from free radicals captured in the shell of shrimp. As a result, it is considered that PSL or ESR methods for detection of gamma-irradiated dried shrimp and only PSL can be used to detect gamma-irradiated seaweed. Furthermore, it is considered that hydrocarbon analysis of seasoned dried filefish containing fat by GC/MS and Thermo Luminance (TL) analysis of dried seaweed should be studied for detection of irradiation.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

스테레오 감마선 탐지장치의 고속 방사선 탐지기법에 관한 연구 (The Study for the Method of Fast and Efficient Gamma-ray Detection for the Stereo Gamma-ray Ddetection System)

  • 황영관;이남호
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1253-1258
    • /
    • 2014
  • In this paper, we propose the fast and efficient detection method using the continuous measurement technique for the gamma-ray signal acquisition. This method is improved than the conventional method for the getting information of the radiation distribution. First, we implement the stereo radiation detection system using gamma-ray sensors and the motion controller. We apply continuous measurement technique to the gamma-ray detector and conduct gamma-ray irradiation test for the comparison of detection techniques. The results show that the continuous measurement technique has the high efficient performance than the conventional method.

Development of an efficient method of radiation characteristic analysis using a portable simultaneous measurement system for neutron and gamma-ray

  • Jin, Dong-Sik;Hong, Yong-Ho;Kim, Hui-Gyeong;Kwak, Sang-Soo;Lee, Jae-Geun;Jung, Young-Suk
    • 분석과학
    • /
    • 제35권2호
    • /
    • pp.69-81
    • /
    • 2022
  • The method of measuring and classifying the energy category of neutrons directly using raw data acquired through a CZT detector is not satisfactory, in terms of accuracy and efficiency, because of its poor energy resolution and low measurement efficiency. Moreover, this method of measuring and analyzing the characteristics of low-energy or low-activity gamma-ray sources might be not accurate and efficient in the case of neutrons because of various factors, such as the noise of the CZT detector itself and the influence of environmental radiation. We have therefore developed an efficient method of analyzing radiation characteristics using a neutron and gamma-ray analysis algorithm for the rapid and clear identification of the type, energy, and radioactivity of gamma-ray sources as well as the detection and classification of the energy category (fast or thermal neutrons) of neutron sources, employing raw data acquired through a CZT detector. The neutron analysis algorithm is based on the fact that in the energy-spectrum channel of 558.6 keV emitted in the nuclear reaction 113Cd + 1n → 114Cd + in the CZT detector, there is a notable difference in detection information between a CZT detector without a PE modulator and a CZT detector with a PE modulator, but there is no significant difference between the two detectors in other energy-spectrum channels. In addition, the gamma-ray analysis algorithm uses the difference in the detection information of the CZT detector between the unique characteristic energy-spectrum channel of a gamma-ray source and other channels. This efficient method of analyzing radiation characteristics is expected to be useful for the rapid radiation detection and accurate information collection on radiation sources, which are required to minimize radiation damage and manage accidents in national disaster situations, such as large-scale radioactivity leak accidents at nuclear power plants or nuclear material handling facilities.

영상처리기반 감마선 분포탐지 효율 개선에 관한 연구 (The Study for Improved Efficiency of the Detection of Radiation Sources Distribution using Image Processing)

  • 황영관;이남호;김종열;정상훈
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.780-781
    • /
    • 2016
  • 스테레오 감마선 공간 탐지장치는 감마선원을 탐지하고 그 결과를 바탕으로 2차원 영상분포를 측정한 후, 스테레오 카메라 기법을 적용하여 3차원 공간상에서 장치로부터 선원까지의 거리를 측정할 수 있도록 구현되었다. 본 논문에서는 영상처리 알고리즘을 통해 감마선 공간 탐지를 위한 스캔시간을 줄이고, 방사광 및 가시광 영상을 중첩한 후 스테레오 보정을 통해 3차원 가시화를 통한 감마선 분포 탐지 효율 개선을 위한 연구를 수행하였다. 탐지시험 결과 고속 탐지를 위한 알고리즘을 적용한다면 단일선원을 탐지할 때 약 30%이상의 탐지효율 개선하였으며, 3D 모니터를 통한 3차원 시각화 영상을 통해 공간상의 선원에 대한 분포를 확인하였다.

  • PDF

방사선 오염분포 영상화를 위한 방사선 센서의 탐지 범위 개선에 관한 연구 (Detection Range Improvement of Radiation Sensor for Radiation Contamination Distribution Imaging)

  • 송근영;황영관;이남호;나준희
    • 한국정보통신학회논문지
    • /
    • 제23권12호
    • /
    • pp.1535-1541
    • /
    • 2019
  • 방사선 사고 지역 및 제염이 필요한 지역에서의 안전하고 신속한 제염작업을 진행하기 위해서는 방사선 오염원에 대한 다양한 정보 획득이 필요하다. 특히 방사선원의 정확한 위치와 분포 정보의 파악은 신속한 후속 조치 및 오염원 제거를 위해 반드시 필요하며, 작업자의 방사선 피폭을 최소화할 수 있다. 방사선원의 위치와 분포 정보를 획득하기 위해서는 방사선 분포 탐지 장치를 사용한다. 방사선 분포 탐지 장치의 경우 일반적으로 탐지 센서 부가 단일 센서로 구성되며, 단일 센서의 물리적 한계로 인해 탐지 범위가 제한되는 문제점이 있다. 본 논문에서는 방사선 오염 분포 영상화 장치에 사용되는 단일 센서의 탐지 감도 제어를 위하여 보정 검출기를 적용하였으며, 이를 통해 제한적이었던 선량률 탐지 범위를 향상하였다. 또한 감마선 조사 시험을 통해 방사선 분포 탐지 범위의 개선을 확인하였다.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.