• Title/Summary/Keyword: Gamma Index

Search Result 451, Processing Time 0.028 seconds

Monitoring of Gamma-ray Bright Quasars 3C279 and 1510-089 at 22, 43 and 86GHz using KVN Single Dish Telescopes

  • Baek, Jun-Hyun;Lee, Sang-Sung;Byun, Do-Young;Yang, Jee-Hye;Han, Myoung-Hee;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.240.2-240.2
    • /
    • 2012
  • AGN(Active Galactic Nucleus) consists of a supermassive black hole located at its center, an accretion disk around the black hole, and bipolar jets. Since May 2011, we have performed the MOGABA(Monitoring Of GAmma-ray Bright AGN) project for observing gamma-ray bright AGN once a week at multifrequencies using KVN(Korean VLBI Network) 21m radio telescopes. The MOGABA project is the observations for measuring the degree of polarization, polarization angle, and total flux of about 20 AGN at 22, 43 and 86GHz. By this project, we are able to investigate polarization characteristics, spectral index, and variation of rotation measure at radio wavelengths of gamma-ray bright AGN and to study possible relation between gamma-ray flares and magnetic field structure change in AGN. According to previous research, gamma-ray flares of some AGN are coincident with large changes in angle of linear polarization. In this paper we report the preliminary results of linear polarization and total flux at 22, 43, 86GHz of gamma-ray bright quasars 3C279 and 1510-089 showing noticeable variation of total flux at 22GHz in late 2011, and discuss possible correlation with gamma ray light curves.

  • PDF

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF

A Study on the Correlation about 7-Zone-Diagnostic System and Clinical Parameters (7구역 진단기와 임상지표와의 상관성 연구)

  • Cho, Woong-Hee;Park, Won-Hyung;Cha, Yun-Yeop
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.1
    • /
    • pp.167-182
    • /
    • 2010
  • Objectives : The purpose of this study is to find correlation about 7-Zone-Diagnostic System and Clinical Parameters using Oriental Health Examination. Methods : Subjects of our study were 325 cases who took Oriental Health Examination. We collected the data of body composition analysis, 7-Zone-Diagnostic System, blood analysis and devided by 7-Zone-Diagnostic system to acceleration, normalcy and depression. Results and Conclusions : The values of muscle mass, body fat mass, abdomen obesity rate, right arm water index, left arm water index, trunk water index, right leg water index, left leg water index, BMI, BMR, GOT, GPT, ${\gamma}$-GTP, BUN, TC, triglyceride and hemoglobin were continuous with 7-Zone-Diagnostic system.

POLYNOMIAL FACTORIZATION THROUGH Lγ(μ) SPACES

  • Cilia, Raffaella;Gutierrez, Joaquin M.
    • Journal of the Korean Mathematical Society
    • /
    • v.46 no.6
    • /
    • pp.1293-1307
    • /
    • 2009
  • We give conditions so that a polynomial be factorable through an $L_{\gamma}({\mu})$ space. Among them, we prove that, given a Banach space X and an index m, every absolutely summing operator on X is 1-factorable if and only if every 1-dominated m-homogeneous polynomial on X is right 1-factorable, if and only if every 1-dominated m-homogeneous polynomial on X is left 1-factorable. As a consequence, if X has local unconditional structure, then every 1-dominated homogeneous polynomial on X is right and left 1-factorable.

CERTAIN FORMULAS INVOLVING A MULTI-INDEX MITTAG-LEFFLER FUNCTION

  • Bansal, Manish Kumar;Harjule, P.;Choi, Junesang;Mubeen, Shahid;Kumar, Devendra
    • East Asian mathematical journal
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2019
  • Since Mittag-Leffler introduced the so-called Mittag-Leffler function, a number of its extensions have been investigated due mainly to their applications in a variety of research subjects. Shukla and Prajapati presented a lot of formulas involving a generalized Mittag-Leffler function in a systematic manner. Motivated mainly by Shukla and Prajapati's work, we aim to investigate a generalized multi-index Mittag-Leffler function and, among possible numerous formulas, choose to present several formulas involving this generalized multi-index Mittag-Leffler function such as a recurrence formula, derivative formula, three integral transformation formulas. The results presented here, being general, are pointed out to reduce to yield relatively simple formulas including known ones.

The expressions of inflammatory factors and tissue inhibitor of matrix metalloproteinase-2 in human chronic periodontitis with type 2 diabetes mellitus

  • Shin, Dong-Seok;Park, Jin-Woo;Suh, Jo-Young;Lee, Jae-Mok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • Purpose: The purpose of this study was to observe and quantify the expression of interleukin-4 (IL-4), interferon-$\gamma$ (IFN-$\gamma$), and tissue inhibitor of matrix metalloproteinase-2 (TIMP-2) in the gingival tissue of patients with type 2 diabetes mellitus (DM) and healthy adults with chronic periodontitis. Methods: Twelve patients with type 2 DM and chronic periodontitis (Group 3), twelve patients with chronic periodontitis (Group 2), and twelve healthy individuals (Group 1) were included in the study. Clinical criteria of gingival (sulcus bleeding index value, probing depths) and radiographic evidences of bone resorption were divided into three groups. The concentrations of cytokines were determined by a western blot analysis and compared using one-way ANOVA followed by Tukey's test. Results: The expression levels of IFN-$\gamma$ and TIMP-2 showed an increasing tendency in Groups 2 and 3 when compared to Group 1. On the other hand, the expression of IL-4 was highest in Group 1. Conclusions: The findings suggest that IFN-$\gamma$ and TIMP-2 may be involved in the periodontal inflammation associated with type 2 DM. IL-4 may be involved in the retrogression of the periodontal inflammation associated with type 2 DM.

A Study on Properties of Charge & Discharge Current by Degrade in EPR (EPR의 열화에 의한 충.방전 전류 특성에 관한 연구)

  • Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.679-685
    • /
    • 2008
  • This paper describes the degraded properties of between the charge and discharge current for ${\gamma}$-ray irradiated in electric power cable rubbers using in nuclear power generating station. The charge and discharge current of degradation in EPR(Ethylene Propylene Rubber), which were irradiated with the radiant capacity of 0.033 Mrad/h, have been measured in order to investigate the influence of the atmosphere(in amount of reinforcing agent, moisture absorption and heat treatment) on electrical properties. When ${\gamma}$-ray were irradiated on the EPR with more reinforcing agent from 4 to 40 Phr, charge and discharge currents was increase due to the amount of reinforcing agent. It was verified that the discharging and charging currents irradiated by ${\gamma}$-ray were higher than those that was not irradiated. The amount of the degraded current was more after moisture absorption than before moisture absorption. The charge and discharge current after heat treatment was similar to that of before heat treatment and it was decreased with the time elapsed. As these properties related with ${\gamma}$-ray irradiation dose, it is suggested that these properties can be utilized as a index of irradiation degradation.

Studies on the Stochastic Generation of Long Term Runoff (2) (장기유출량의 추계학적 모의 발생에 관한 연구 (II))

  • 이순혁;맹승진;박종국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.117-129
    • /
    • 1993
  • This study was conducted to get reasonable and abundant hydrological time series of monthly flows simulated by a best fitting stochastic simulation model for the establishment of rational design and the rationalization of management for agricultural hydraulic structures including reservoirs. Comparative analysis carried out for both statistical characteristics and synthetic monthly flows simulated by the multi-season first order Markov model based on Gamma distribution which is confirmed as good one in the first report of this study and by Harmonic synthetic model analyzed in this report for the six watersheds of Yeong San and Seom Jin river systems. 1.Arithmetic mean values of synthetic monthly flows simulated by Gamma distribution are much closer to the results of the observed data than those of Harmonic synthetic model in the applied watersheds. 2.In comparison with the coefficients of variation, index of fluctuation for monthly flows simulated by two kinds of synthetic models, those based on Gamma distribution are appeared closer to the observed data than those of Harmonic synthetic model both in Yeong San and Seom Jin river systems. 3.It was found that synthetic monthly flows based on Gamma distribution are considered to give better results than those of Harmonic synthetic model in the applied watersheds. 4.Continuation studies by comparison with other simulation techniques are to be desired for getting reasonable generation technique of synthetic monthly flows for the various river systems in Korea.

  • PDF

Comparative Studies on the Simulation for the Monthly Runoff (월유출량의 모의발생에 관한 비교 연구)

  • 박명근;서승덕;이순혁;맹승진
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.38 no.4
    • /
    • pp.110-124
    • /
    • 1996
  • This study was conducted to simulate long seres of synthetic monthly flows by multi-season first order Markov model with selection of best fitting frequency distribution, harmonic synthetic and harmonic regression models and to make a comparison of statistical parameters between observes and synthetic flows of five watersheds in Geum river system. The results obtained through this study can be summarized as follow. 1. Both gamma and two parameter lognormal distributions were found to be suitable ones for monthly flows in all watersheds by Kolmogorov-Smirnov test. 2. It was found that arithmetic mean values of synthetic monthly flows simulated by multi-season first order Markov model with gamma distribution are much closer to the results of the observed data in comparison with those of the other models in the applied watersheds. 3. The coefficients of variation, index of fluctuation for monthly flows simulated by multi-season first order Markov model with gamma distribution are appeared closer to those of the observed data in comparison with those of the other models in Geum river system. 4. Synthetic monthly flows were simulated over 100 years by multi-season first order Markov model with gamma distribution which is acknowledged as a suitable simulation modal in this study.

  • PDF

SMALL DATA SCATTERING OF HARTREE TYPE FRACTIONAL SCHRÖDINGER EQUATIONS IN DIMENSION 2 AND 3

  • Cho, Yonggeun;Ozawa, Tohru
    • Journal of the Korean Mathematical Society
    • /
    • v.55 no.2
    • /
    • pp.373-390
    • /
    • 2018
  • In this paper we study the small-data scattering of the d dimensional fractional $Schr{\ddot{o}}dinger$ equations with d = 2, 3, $L{\acute{e}}vy$ index 1 < ${\alpha}$ < 2 and Hartree type nonlinearity $F(u)={\mu}({\mid}x{\mid}^{-{\gamma}}{\ast}{\mid}u{\mid}^2)u$ with max(${\alpha}$, ${\frac{2d}{2d-1}}$) < ${\gamma}{\leq}2$, ${\gamma}$ < d. This equation is scaling-critical in ${\dot{H}}^{s_c}$, $s_c={\frac{{\gamma}-{\alpha}}{2}}$. We show that the solution scatters in $H^{s,1}$ for any s > $s_c$, where $H^{s,1}$ is a space of Sobolev type taking in angular regularity with norm defined by ${\parallel}{\varphi}{\parallel}_{H^{s,1}}={\parallel}{\varphi}{\parallel}_{H^s}+{\parallel}{\nabla}_{{\mathbb{S}}{\varphi}}{\parallel}_{H^s}$. For this purpose we use the recently developed Strichartz estimate which is $L^2$-averaged on the unit sphere ${\mathbb{S}}^{d-1}$ and utilize $U^p-V^p$ space argument.