• 제목/요약/키워드: Gamma (${\gamma}$)-ray

검색결과 1,824건 처리시간 0.03초

감마선을 이용한 케나프 펄프 표면의 Poly(ethylene glycol) Methacrylate 그라프트 중합반응 (Surface Graft Polymerization of Poly(ethylene glycol) Methacrylate onto Kenaf Pulp using Gamma-ray Irradiation)

  • 오두리;전준표;강필현
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.251-255
    • /
    • 2012
  • Pulp is typically used for paper industry to manufacturing various types of papers. However simply chemical modification makes enable the pulp to a wide range of application in various industrial fields. To bring the polymerization the gamma ray irradiated on the mixture of kenaf and PEGMA in various dose ranges from 20 to 60 kGy. As a results, the graft degree of 20.0% was obtained from 475 g of gamma ray irradiated pulp and PEGMA. After the polymerization, the chemical structure and morphology of the surfaces were examined by Fourier transform infrared spectroscopy, thermogravimetric analysis, and scanning electron microscope. Chemical structure of grafted pulp has significantly growth in carbonyl content with increasing the radiation dose. Also surface morphology was distinctly changed with decreased the degree of roughness and increasing the diameter. These results were explained gamma ray irradiation improve performance of graft polymerization efficiency.

감마선 조사를 이용하여 Poly(ethylene glycol) Mathacrylate가 그래프팅된 케냐프 섬유를 포함하는 시멘트 복합재료의 제조 (Preparation of Cement Composites Containing Kenaf Fiber Has Been Gamma-ray Grafted with Poly(ethylene glycol) Methacrylate)

  • 이병민;강필현;전준표
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.49-52
    • /
    • 2014
  • Kenaf fibers have excellent properties and possess the potential to be outstanding reinforcing fillers in cement. The grafting of poly(ethylene glycol) methacrylate (PEGMA) to the kenaf fibers is important in improving the compatibility between the fibers and the cement. PEGMA was grafted onto kenaf fibers using gamma-ray radiation. The radiation dose ranged from 20 to 60 kGy, and the dose rate was $10kGy\;h^{-1}$. The degree of grafting increased with increased radiation doses. FT-IR analysis revealed an increase in PEGMA content after gamma-ray radiation induced grafting, further evincing the attachment of PEGMA to the kenaf fibers. The mechanical properties of the gamma-ray grafted kenaf fiber/cement composites were superior to those of the ungrafted kenaf fiber/cement specimens.

Flexible liquid light-guide-based radiation sensor with LaBr3:Ce scintillator for remote gamma-ray spectroscopy

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Taeseob Lim;Jinhong Kim;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1045-1051
    • /
    • 2023
  • In this study, we fabricated a liquid light-guide-based radiation sensor with a LaBr3:Ce scintillator for remote gamma-ray spectroscopy. We acquired the energy spectra of Cs-137 and Co-60 using the proposed sensor, estimated the energy resolutions of the full energy peaks, and compared the scintillation light output variations. The major peaks of the radionuclides were observed in each result, and the estimated energy resolutions were similar to that of a general NaI(Tl) scintillation detector without a liquid light guide. Moreover, we showed the relationships of energy resolution and analog-to-digital channel regarding the number of photoelectrons produced and confirmed the effects of light guide length on remote gamma-ray spectroscopy. The proposed sensor is expected to be utilized to perform remote gamma-ray spectroscopy for distances of 3 m or more and would find application in many fields of nuclear facilities and industry.

Fabrication and Evaluation of Spectroscopic Grade Quasi-hemispherical CdZnTe Detector

  • Beomjun Park;Kyungeun Jung;Changsoo Kim
    • Journal of Radiation Protection and Research
    • /
    • 제49권2호
    • /
    • pp.85-90
    • /
    • 2024
  • Background: This study focuses on the fabrication and characterization of quasi-hemispherical Cd0.9Zn0.1Te (CZT) detector for gamma-ray spectroscopy applications, aiming to contribute to advancements in radiation measurement and research. Materials and Methods: A CZT ingot was grown using the vertical Bridgman technique, followed by proper fabrication processes including wafering, polishing, chemical etching, electrode deposition, and passivation. Response properties were evaluated under various external bias voltages using gamma-ray sources such as Co-57, Ba-133, and Cs-137. Results and Discussion: The fabricated quasi-hemispherical CZT detector demonstrated sufficient response properties across a wide range of gamma-ray energies, with sufficient energy resolution and peak distinguishability. Higher external bias voltages led to improved performance in terms of energy resolution and peak shape. However, further improvements in defect properties are necessary to enhance detector performance under low bias conditions. Conclusion: This study underscores the efficacy of quasi-hemispherical CZT detector for gamma-ray spectroscopy, providing valuable insights for enhancing their capabilities in radiation research field.

저선량 ${\gamma}$ 선 조사가 배추와 무 종자의 발아와 양분흡수에 미치는 영향 (Effects of low dose ${\gamma}$ radiation on the uptake of mineral nutrients in chinese cabbage and radish)

  • 윤영만;김남범;김재성;김정규
    • 한국환경농학회지
    • /
    • 제18권4호
    • /
    • pp.344-348
    • /
    • 1999
  • 배추와 무의 영양생리에 대한 저선량${\gamma}$선에 의한 자극작용의 영향을 파악하고자 1998년산 흑진주배추, 1995년산 서림엇갈이배추, 1998년산 청운무 종자에 1에서 10Gy의 저선량 ${\gamma}$선을 조사하고 생육시기에 따른 생장량과 무기양분의 변화를 분석하였다. 공시된 배추품종들은 조사선량의 증가에 따라서 발아율과 건물생산량이 증가하는 경향을 보였다. 건물생산의 증가는 흑진주배추에서 가장 현저하여 10Gy 처리구에서 143%로 증가되었고, 서림엇갈이배추는 10Gy에서 138%로 증가하였다. 청운무는 ${\gamma}$선 조사에 따른 발아율과 건물생산량의 일관된 경향성을 보이지 않았다. 무기영양소들의 함량변화는 선량-반응 곡선의 ${\gamma}$ 또는 ${\delta}$형을 나타내 ${\gamma}$선에 의한 자극효과가 일부처리구에서 나타나기는 하였지만 일반적 현상이라고 인정하기 어려웠다. 따라서 저선량 ${\gamma}$조사가 배추와 무의 영양생리에 미치는 영향을 정확하게 파악하기 위한 연구결과의 집적이 필요할 것으로 판단된다.

  • PDF

방사성동위원소의 지구물리학적 응용에 관한 연구 γ-γ 검층법에 의한 지층구조에 관한연구 (Study on the Geophysical Research Applications Using Radioactive Isotopes (I) Study on the Structures in Strata by Using γ-γ Logging Apparatus)

  • 이현덕;노성기
    • 자원환경지질
    • /
    • 제9권3호
    • /
    • pp.135-141
    • /
    • 1976
  • The gamma-gamma logging method appplying in geophysical research are presented in this paper_ The logging probe assembly was designed which permits changing the source-to-detector spacing while conditions of proceeding ${\gamma}-{\gamma}$ logging, which a collimated gamma ray source ($^{60}Co$, 0.5mCi and/or 2 mCi) is separated from the scintillation detector as shown in Fig. 2 and 3, size is 6.0 cm in diameter and 120.0 cm in long and the exposed parts are made of stainless steel pipe. The results is confirmed by the experiment performed mainly in granite rock where a slightly constant shape was obtained but sometimes was shown sharpness shape for the measured scattered gamma-ray intensity. Consequently, the experimental results are obtained an adequate intensity of scattered gamma-rays and favourable response to density change, and also very closely correspond to between core samples of the test boring and to used this method of ${\gamma}-{\gamma}$ logging in the test bore-hole of the strata.

  • PDF

Monte-Carlo simulation for detecting neutron and gamma-ray simultaneously with CdZnTe half-covered by gadolinium film

  • J. Byun ;J. Seo ;Y. Kim;J. Park;K. Shin ;W. Lee ;K. Lee ;K. Kim;B. Park
    • Nuclear Engineering and Technology
    • /
    • 제55권3호
    • /
    • pp.1031-1035
    • /
    • 2023
  • Neutron is an indirectly ionizing particle without charge, which is normally measured by detecting reaction products. Neutron detection system based on measuring gadolinium-converted gamma-rays is a good way to monitor the neutron because the representative prompt gamma-rays of gadolinium have low energies (79, 89, 182, and 199 keV). Low energy gamma-rays and their high attenuation coefficient on materials allow the simple design of a detector easier to manufacture. Thus, we designed a cadmium zinc telluride detector to investigate feasibility of simultaneous detection of gamma-rays and neutrons by using the Monte-Carlo simulation, which was divided into two parts; first was gamma-detection part and second was gamma- and neutron-simultaneous detection part. Consequently, we confirmed that simultaneous detection of gamma-rays and neutrons could be feasible and valid, although further research is needed for adoption on real detection.

CZT 반도체 검출기를 활용한 중성자 및 감마선 측정과 분석 기술에 관한 연구 (A Study on the Technology of Measuring and Analyzing Neutrons and Gamma-Rays Using a CZT Semiconductor Detector)

  • 진동식;홍용호;김희경;곽상수;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.57-67
    • /
    • 2022
  • CZT detectors, which are compound semiconductors that have been widely used recently for gamma-ray detection purposes, are difficult to detect neutrons because direct interaction with them does not occur unlike gamma-rays. In this paper, a method of detecting and determining energy levels (fast neutrons and thermal neutrons) of neutrons, in addition of identifying energy and nuclide of gamma-rays, and evaluating gamma dose rates using a CZT semiconductor detector is described. Neutrons may be detected by a secondary photoelectric effect or compton scattering process with a characteristic gamma-ray of 558.6 keV generated by a capture reaction (113Cd + 1n → 114Cd + 𝛾) with cadmium (Cd) in the CZT detector. However, in the case of fast neutrons, the probability of capture reaction with cadmium (Cd) is very low, so it must be moderated to thermal neutrons using a moderator and the material and thickness of moderator should be determined in consideration of the portability and detection efficiency of the equipment. Conversely, in the case of thermal neutrons, the detection efficiency decreases due to shielding effect of moderator itself, so additional CZT detector that do not contain moderator must be configured. The CZT detector that does not contain moderator can be used to evaluate energy, nuclide, and gamma dose-rate for gamma-rays. The technology proposed in this paper provides a method for detecting both neutrons and gamma-rays using a CZT detector.

방사선조사 유래의 조기출수 식물(Oryza sativa L.) 계통의 유전적 변이 분석 (Genetic Variation Analysis of Early-heading Plant (Oryza sativa L.) Lines Derived from Gamma-ray Irradiation)

  • 류재혁;소현수;류재일;권오도;이영일;진일두;이효연;배창휴
    • 한국자원식물학회지
    • /
    • 제25권1호
    • /
    • pp.142-151
    • /
    • 2012
  • 식물유전자원의 소재를 확대하고자 동진 1호 벼의 건조 종자에 감마선($^{60}Co$, 300 Gy)을 조사하여 선발한 조기출수 계통의 유전적 변이성을 분석하였다. 선발한 조기출수 계통의 $M_7$(2010년)과 $M_8$(2011년) 세대에서 평균 출수기는 대조품종인 동진 1호(중만생종) 보다 각각 11일(${\gamma}$-2 계통), 10일(${\gamma}$-5 계통), 6일(${\gamma}$-1 계통), 5일(${\gamma}$-3 계통), 4일(${\gamma}$-4 계통)이 빠르게 나타났다. ISSR 분석 결과, 선발계통의 유전적 다형성은 ${\gamma}$-2 계통 5.9%, ${\gamma}$-1 계통 7.5%, ${\gamma}$-4 계통 15.1%, ${\gamma}$-3 계통 15.3%, X-1 계통 19.4%, ${\gamma}$-5 계통 23.4%로 대조품종의 4.3% 보다 높게 나타나 방사선 조사로 DNA 수준에서 변이가 증가되었음을 확인하였다. 엽록체 DNA(rps16-trnK 영역) 분석 결과, 염기 길이는 대조 품종과 같은 664 bp인 반면, 총 5개 염기서열 영역에서 치환 변이가 발생하였고 그 중 6 bp 및 587 bp 영역의 변이는 선발 계통에서만 나타났다.

감마선 조사가 휴민산 염소화에 의한 THMs 생성능 및 수질특성에 미치는 영향 (Effect of γ-ray Irradiation on THMs Formation and Water Quality Characteristics in the Chlorination of Humic Acid Contaming Water)

  • 강철호;임현우;정성운;최종혁;김종훈;최용욱;이면주
    • 한국물환경학회지
    • /
    • 제26권6호
    • /
    • pp.1034-1039
    • /
    • 2010
  • Variation of formation potential of THM (THMFP) by chlorination of humic acid and characteristics of water quality with ${\gamma}$-ray irradiation were investigated, which were divided into two categories by the order of ${\gamma}$-ray irradiation and chlorination in water treatment process. The group A consisted of the ${\gamma}$-ray irradiation followed by chlorination process of humic acid, and the group B consisted of the chlorination followed by ${\gamma}$-ray irradiation process. The pH, ORP, $UV_{254}$, and DOC decreased rapidly with an increase in ${\gamma}$-ray irradiation of 3 kGy. while conductivity was little changed. Maximum degradation ratio of chloroform in THMs of group A was 82%, while that in group B was 69%. No brominated THMs were detected at high irradiation (>3 kGy). We found that group A water treatment process was more effective in lowering the THMFP than that of group B.