• 제목/요약/키워드: Gain factor

검색결과 806건 처리시간 0.029초

정보통신기기 품목간 유망성 비교 방법론 (A Method on the Selection of the Promising IT Equipment)

  • 김수현;주영진;박석지
    • 기술혁신학회지
    • /
    • 제2권2호
    • /
    • pp.266-274
    • /
    • 1999
  • The world market is being restructured into one global market. The globalization makes the competition m IT industry more vigorous. It is, therefore, the vital procedures that the selection of the promising items among IT equipment and the intensive investment on the selected items to gain the competitiveness in the area of IT global market. With these in mind, in this paper, we introduce a very systematic and objective method which appraises the promise of IT equipment. The method is based on the factor Analysis which is very popular and powerful statistical technique.

  • PDF

3-stage 운전에 의한 3상 DCM컨버터의 입력 역률개선 (Power Factor Correction of Three Phase DCM Converter by 3-stage Operation)

  • 최해룡;구영모;김응진;목형수;최규하;김규식;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.659-662
    • /
    • 1999
  • As utility pollution take a growing interest, ac/dc converter optimizing utility condition has been vigorously studied in decades. In this paper three phase DCM converter is analyzed and equations for average input currents are presented. Also relationships of voltage gain & duty according to angular velocity are presented and variable frequency controller is implemented using reset integrator which is designed in detail. In result power factor and THD characteristics of 3-stage and 4-stage operation ae compared respectively.

  • PDF

차세대 항공 감시시스템(ADS-BES) 지상국 수신기 저잡음 증폭기 설계 및 구현 (Designing and Realizing the Ground Station Receiver Low Noise Amplifier of the Next-Generation Aeronautical Surveillance System)

  • 조주용;윤준철;박찬섭;박효달;강석엽
    • 한국정보통신학회논문지
    • /
    • 제17권10호
    • /
    • pp.2273-2280
    • /
    • 2013
  • 본 논문에서는 차세대 항공 감시시스템에 대하여 소개하고, 지상국 수신기 전단부 저잡음 증폭기 설계에 관하여 연구하였다. 국제 표준 문서와 기존 제품의 성능을 고려하여 수신감도, 신뢰성 등이 경쟁력 있게 전체 시스템을 링크 버짓 하였으며, 이에 적합한 저잡음 증폭기를 얻기 위해 이득, 이득 평탄도, 반사손실 등을 최적이 되도록 설계 규격을 결정하였다. 설계시 저전력, 저잡음, 고이득 특성에 적합한 바이어스 회로를 구성하였으며, 최적 설계 후 실시한 모의실험 결과로 이득은 16.24dB, 잡음지수는 0.36dB, 입출력 반사손실은 각각 -18dB와 -28dB, 주파수 안정도는 1.11을 얻었고, 제작 후 측정 결과는 이득 17dB, 잡음지수 0.51dB, 이득 평탄도 0.23dB, 입출력 반사손실은 각각 -18.28dB, -24.50dB로 전체 시스템 구성에 적합한 결과를 얻었다.

의료 지속성에 대한 일반인들의 태도 및 관련요인 - 사무직 직원들을 대상으로 - (A Study on the general population's attitude and related factor on the continuity of medical care)

  • 조희숙;정헌재;이선희
    • 한국병원경영학회지
    • /
    • 제9권3호
    • /
    • pp.1-17
    • /
    • 2004
  • This study is aimed to assess the general population's attitude toward the continuity of medical care and its related factors. Self administered questionnaire was performed on the 1,120 office workers in the C city, Gang-won province. The questionnaire included the attitude of the continuity of medical institute, the intention of medical service use on a given case, and the variables of the related factors. 58.8% of the total respondents agreed to sustaining treatment without changing medical institutes; on the other hand, 41.2% showed negative attitude. In case that a patient would gain a recommendation of a surgery, hospitalization, or a specific examination, the total respondents' 84.9%, 61.8%, and 50.8% of each recommended situation said that they would visit another doctor and gain a diagnosis. As a result of multiple logistic analysis of determinant factor on continuity, reliability of doctors was statistically significant factor. In order to reduce wastefully used medical resources and offer well-qualified medical service, a system of second opinion among peer group or beforehand agreement could be possibly adopted. In addition, improving the image and reliability of a doctor could be an important factor to make better the behavior of medical service shopping; therefore, an effort to improve the relationship between a doctor and a patient, and restore the reliability of doctors should be paralleled.

  • PDF

가변 Q-factor를 가지는 디지털 그래픽 이퀄라이저 (A Digital Graphic Equalizer with Variable Q-factor)

  • 이용희;김인철
    • 방송공학회논문지
    • /
    • 제8권1호
    • /
    • pp.3-10
    • /
    • 2003
  • 본 논문에서는 대역 및 이득에 따라 Q-factor를 가변 시키는 필터를 채용한 가변 Q 디지털 그래픽 이퀄라이저 필터를 제안한다. 제안한 이퀄라이저는 가청 주파수 대역에서 대칭적인 주파수응답을 보인다. 그리고, 동일한 수준의 하드웨어 복잡도를 유지하면서도 기존의 방법에 비해 실제 응답이 원하는 응답에 더 근접하는 것을 보인다. 또한 중심주파수 선정에 따른 성능 변화에 대해서도 고찰한다.

Fibroblast Growth Factor Receptor 3 (FGFR3) Signaling in Achondroplasia

  • Park, Sung Won
    • Journal of mucopolysaccharidosis and rare diseases
    • /
    • 제2권2호
    • /
    • pp.46-49
    • /
    • 2016
  • Achondroplasia is autosomal dominant genetic disease and fibroblast growth factor receptor 3 (FGFR3) is currently known to be the only gene that causes achondroplasia. Gain-of function mutation in fibroblast-growth-factor-receptor 3 (FGFR3) causes the disease and C-type natriuretic peptide (CNP) antagonizes FGFR3 downstream signaling by inhibiting the pathway of mitogen-activated protein kinase (MAPK). As FGFR3-related skeletal dysplasias are caused by growth attenuation of the cartilage, chondrocytes appear to be unique in their response to FGFR3 activation. However, the full spectrum of molecular events by which FGFR3 mediates its signaling is just beginning to emerge. This article summaries the mechanisms of FGFR3 function in skeletal dysplasias, the extraordinary cellular manifestations of FGFR3 signaling in chondrocytes, and finally, the progress toward therapy for ACH.

전류 제어 루프에 보상을 행하지 않는 능동 역률 제어 AC/DC 컴버터의 제어기 설계 (Design of active power factor control AC/DC converter having current control loop with no compensator)

  • 이인호;김성환;유지윤;박귀태
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.216-223
    • /
    • 1996
  • The active power factor control AC/DC converter needs a current loop compensator to obtain better dynamic characteristics and power factor performance, but the optimal design of a current loop compensator is difficult because the AC/DC converter is a nonlinear system having periodically varying poles and zeros. The predictive current control scheme generates a control input using the dynamic equations of the AC/DC converter so that the dynamic of the AC/DC converter is included in the controller and the necessary bandwidth and the gain characteristics of the current control loop are satisfied. And as a result, a compensator becomes unnecessary and the current loop shows the improved current loop characteristics. In this paper, a power factor controller without current loop compensator by adopting a predictive current control scheme is designed and the designed power factor controller is modelled by using a small signal perturbation modelling technique, and simulated to investigate its small signal characteristics. A 200 W power factor control AC/DC converter is built to verify the effectiveness of the proposed power factor controller.

  • PDF

단일 입출력 시스템에 대한 IMC-PID의 새로운 최적 동조법 (New Optimal Tuning Method of IMC-PID for SI/SO Systems)

  • 김창현;임동규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.213-217
    • /
    • 2008
  • 본 논문에서는 표준 IMC-PID 제어기에 시스템 식별상의 위상 조절 인자를 설계 변수로 추가함으로 새로운 IMC-PID 제어기 설계 방법을 제안한다. 제안된 제어기의 동조법으로 해석적으로 구해진 주파수 영역 특성을 통해 주파수 영역 성능을 보장하도록 하는 설계 변수의 구속 조건 하에서 시간영역의 적분 오차 지표를 가격함수로 최소화하는 최적 해를 얻는다. 이 제안된 동조법은 다양한 설계 사양을 동시에 고려하도록 하여 기존의 IMC-PID의 단일 설계 변수 동조가 갖는 비유연성 문제를 개선하였다. 사례 연구에서 기존의 동조법들과의 성능 비교를 통해 그 유용성을 검토했다.

  • PDF

AC와 DC 노이즈가 있는 적분기 시스템에서 측정에러의 영향을 감소시키는 스위칭 상태 궤환 제어기의 설계 및 분석 (Design and Analysis of a Switching State Feedback Controller to Reduce the Measurement Error Effect for a Chain of Integrators System under AC and DC Noise)

  • 오상영;최호림
    • 제어로봇시스템학회논문지
    • /
    • 제20권1호
    • /
    • pp.12-17
    • /
    • 2014
  • In this paper, we propose a controller capable of reducing the effect of measurement errors under AC and DC noise. Typically, the control system measures data through a sensor. If sensor noise is included in a controller via the feedback channel, the signal is distorted and the entire system cannot work normally. Therefore, some appropriate action to counter the measurement error effect is essential in the controller design. Our controller is equipped with a gain-scaling factor and a compensator to reduce the effect of measurement error in the feedback signal. Also, we use a switching control strategy to enhance the performance of the controller regarding convergence speed. Our proposed controller can therefore effectively reduce the AC and DC noise of the sensor. We analyze the proposed controller by Laplace transform technique and our control method is verified via MATLAB simulation.