• Title/Summary/Keyword: GacA

Search Result 237, Processing Time 0.037 seconds

Effect of Advanced Treatment Process for Residual Chlorine Decay and THM Formation in Water Distribution System (고도처리공정이 관로 내 잔류염소 감소 및 THM 생성에 미치는 영향)

  • Lee, Doo-Jin;Kim, Young-Il;Kim, Sung-Su;Lee, Kyung-Hyuk;Park, Hyun-A
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.4
    • /
    • pp.419-424
    • /
    • 2007
  • According to increase of consumer's desire for clean tap water, advanced treatment processes include with membrane, ozone, and granular activated carbon(GAC) were introduced. In order to evaluate the effect of advanced treatment processes for residual chlorine decay and trihalomethane(THM) formation in water distribution system, dissolved organic matter(DOC) removal of each advanced treatment process was investigated. The residual chlorine decay and THM formation using bottle tests were also evaluated. $UV_{254}$ removal in all advanced treatment was better than DOC removal. Especially, DOC by ozone treated was removed as 4% in contrast with sand filtered water, but $UV_{254}$ was removed about 17%. This result might be due to convert from hydrophobic DOC to hydrophilic DOC by ozonation. Ozone/GAC process was most effective process for DOC removal. The residual chlorine decay constants in treated water by sand filtration, ozonation, GAC adsorption, and ozone/GAC processes were 0.0230, 0.0307, 0.0117 and 0.0098 $hr^{-1}$, respectively. The sand filtered water was produced 81.8 ${\mu}g/L$ of THM after 190 hours of reaction time, as the treated water by ozone, GAC, and Ozone/GAC was less produced 6.0, 26.2, 30.3% in contrast with sand filtered water, respectively. Consequently, the durability of residual chlorine and reduction of THM formation were improved by advanced treatment processes.

Study on Feasibility of Fluidized Bed Membrane Reactor with Granular Activated Carbon Particles as Fluidized Media to Treat Metal-plating Wastewater (도금폐수처리를 위한 입상활성탄 유동 메디아 적용 유동상 멤브레인 여과기술의 적용가능성 평가에 관한 연구)

  • Chang, Soomin;Kwon, Deaeun;Kim, Jeonghwan
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.252-259
    • /
    • 2018
  • An acidic, real metal-plating wastewater was treated by a fluidized bed membrane reactor introduced with granular activated carbon (GAC) as fluidized media. With GAC fluidization, there was no increase in suction pressure with time at each flux set-point applied. At neutral solution pH, much less fouling rate was observed than acidic pH under GAC fluidization. Higher solution pH resulted in the increase in particle size in metal-finishing wastewater, thus producing a less dense cake structure on membrane. More than 95% of chemical oxygen demand was observed from the fluidized bed membrane reactor under GAC fluidization. Total suspended solid concentration in membrane permeate was near zero. At the raw wastewater pH, no removal of copper and chromium by the fluidized bed membrane reactor was observed. As the pH was increased to 7.0, removal efficiency of copper and chromium was increased considerably to 99 and 94%, respectively. Regardless of solution pH tested, more than 95% of cyanide was removed possibly due to the strong adsorption of organic-cyanide complex on GAC in fluidized bed membrane reactor.

Removal of Phenol Loaded with Activated Carbon by Potentiostatic Method (정전위전해에 의한 활성탄에 함유된 페놀 제거)

  • 김성우;박승조
    • Resources Recycling
    • /
    • v.10 no.4
    • /
    • pp.18-23
    • /
    • 2001
  • Air pollutants, phenol was generated in case of thermal regeneration of used activated carbon loaded with phenol and because of this problem, removal process of phenol were studied. Electrolytic oxidation of samples, used S.company granular activated carbon (WS-GAC), used C.company granular activated carbon (WC-GAC) and used L.company granular activated carbon (WL-GAC) loaded with phenol carried out by potentiostatic method in this study. In case of experiment was to come into operation in condition of samples containing 100 mg/g phenol, supporting electrolyte was 1.0% sodium chloride solution, Ti-Ir (10$\times$10$\textrm{cm}^2$) electrode and electrode distance was 2 cm, current density was $1.25 A/dm^2$, Obtained from the results of electrolytic oxidation experiments were not detected residual phenol. And then we knew about reaction time of electrolytic oxidation, current density, concentration of supporting electrolyte and electrode and electrode distance were 60 minutes, 1.25 A/dm$^2$, 1.0%, 2 cm.

  • PDF

Decision of Backwashing frequency and method on the GAC adsorber (입상활성탄 흡착지 운영에서 역세척 주기와 팽창률의 영향 평가)

  • Chae, Seon-Ha;Cho, Chang-Hyun;Lee, Hee-Dae;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.753-762
    • /
    • 2010
  • The objective of this study was to evaluate the backwashing frequency and method on the Granular Activated Carbon (GAC) in G WTP. A backwashing period was determined as 50 days and 60 days, respectively. Prior to Backwashing by head loss build, biomass concentration in effluent as constant and DO concentration was maintained more than 11.5 mg/L in GAC bed. Peak turbidity of backwashing water was 73.6~303 NTU. Mean turbidity of backwashing water at initial 9 minute of backwash operation was 50.7~82.8 NTU. After 30 minute backwashing operation, final turbidity reaches approximately 10 NTU. The frequency of backwashing and turbidity of backwashing water overtime were evaluated. At 20days of backwashing frequency, the peak turbidity was 73 NTU and 42 NTU respectively when 10% and 25% of expansion of GAC were applied. At 14 minute of backwashing time, it was observed that turbidity of 10% expansion of GAC was higher than that of 20% expansion.

Treatment of ETA wastewater using GAC as particle electrodes in three-dimensional electrode reactor (활성탄 충진 3D 복극전기분해조를 이용한 ETA 처리)

  • Kim, Ran;Kim, Yu-Jin;Shin, Ja-Won;Kim, Jeong-Joo;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.2
    • /
    • pp.241-249
    • /
    • 2013
  • Ethanolamine (ETA) is widely used for alkalinization of water in steam cycles of nuclear power plants with pressurized water reactor. When ETA contained wastewater was released, it could increase COD and T-N. The treatment of the COD and T-N from ETA wastewater was investigated using the GAC as particle electrodes in three-dimensional electrode reactor (TDE). This study evaluated the effectiveness of GAC as particle electrode using different packing ratio at 300 V. The results showed that GAC-TDE could reduce ETA much more efficiently than ZVI-TDE at the mass ratio of GAC to insulator, 1:2. Additionally, The effect of applied electric potential to COD and T-N reduction was investigated. The results showed the high COD, T-N reduction and current efficiency at the low electric potential. Using the GAC-TDE will provide a better ETA reduction with reducing electrical potential dissipation.

Advanced Water Treatment of High Turbidity Source by Hybrid Process of Ceramic Microfiltration and Activated Carbon Adsorption: Effect of GAC Packing Fraction (세라믹 정밀여과 및 활성탄 흡착 혼성공정에 의한 고탁도 원수의 고도정수처리: 입상 활성탄 충전율에 의한 영향)

  • Park, Jin-Yong;Lee, Hyuk-Chan
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • In this study, we used hybrid module that was composed of packing granular activated carbon (GAC) between module inside and outside of ceramic microfiltration membrane for advanced drinking water treatment. Instead of natural organic matters (NOM) and fine inorganic particles in natural water source, synthetic water was prepared with humic acid and kaolin. Packing fraction of GAC was changed from 0 to 24.05% to see effect of packing fraction. As a result, changing curves of resistance of membrane fouling ($R_f$) and permeate flux (J) during 3 h operation were almost overlapped independent of packing fraction of GAC. Treatment efficiencies of turbidity were very high above 99.46% at all packing fractions of GAC. And treatment efficiency of NOM, which was measured by $UV_{254}$ absorbance, was the highest value of 99.43% at packing fraction of 24.05%. Then, we operated the hybrid process during 13 h at packing fraction of 24.05%. As a result, J was rapidly dropped according to increase of membrane fouling within initial 1 h of operation, and almost constant after 3 h. And treatment efficiencies of turbidity and NOM were stable and high values of 99.52% and 96.63%, respectively.

An Experimental Study on the Toluene Control Characteristics of Biofilter Packed with Compost, Peatmoss and GAC (Compost, Peatmoss, GAC의 복합 메디아로 충전된 Biofilter의 Toluene 제어특성에 관한 실험적 연구)

  • Eom, Yun-Sung;Han, Se-Hyun;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.3
    • /
    • pp.265-276
    • /
    • 2007
  • The primary objective of this study is to investigate the effect of media on the performance of biofilters. Two types of experiments were carried out in this study. The first type of experiment used a biofilter with the media composed of three different packing materials of compost, peatmoss and GAC(granular activated carbon), whereas the second type used a biofilter with the media composed of compost only. It was found from the two experiments that the biofilter composed of compost, peatmoss and GAC showed better performance than the one composed of compost only with the higher toluene removal efficiency, lower pressure drop, and more uniform media moisture content. In particular, no appreciable media compression occurred for the biofilter composed of compost, peatmoss and GAC, whereas significant media compression took place in the biofilter composed of compost only. As suggested by the other researchers, it is likely that GAC may be responsible for the higher toluene removal efficiency in the case of the biofilter composed of mixed media especially for the early stage of biofiltration due to its adsorption capability of toluene of such high concentration as 300 ppm. It was also regarded that GAC may playa major role in maintaining lower media pressure drop in the case of the mixed media than the media with compost only because of its mechanical strength resisting to the compression. Nonetheless, further refined experiments may need to draw more accurate conclusion. The results of the additional test run using the same mixed media showed that the biofilter system using the mixed media can be consistently operated for more than 100 days very stably despite sudden change in operating conditions of temperature and flow rate.

Bacterial regrowth in biofilms formed in granular activated carbon filter adsorbers and the bacterial isolation and identification (입상 활성탄 여과지에서 세균의 재성장과 생물막 형성 세균의 분리 및 동정)

  • Lee, Gyucheol;Kwon, Soonbok;Lee, Byungki;Park, Jonggeun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • This study aimed to investigate the biofilm formation, bacterial regrowth, and bacterial community structure in the granular-activated carbon (GAC) filter adsorbers (FAs) used in water treatment plants. In 2005 and 2006, raw water, settled water, GAC FA by depth, and filtered water were collected twice a year from water treatment plants (WTPs) B and S. The number of heterotrophic bacteria, including mesophilic and psychrophilic bacteria, in such collected waters was investigated along with the total number of coliforms therein. Heterotrophic bacteria were detected in most samples, mainly at the surface layers of the GAC FAs, and fewer such bacteria were found in the lower and bottom layers. An increase in the bacterial number, however, was observed in the samples from various depths of the GAC FAs in WTPs B and S compared with the surface layers. An increase in the bacterial number was also detected in the filtered water. This may indicate that there is a regrowth of the bacteria in the GAC FA. Considering, however, that heterotrophic bacteria were not found in the filtered water, it can be deduced that most bacteria are removed in the chlorination process. Coliforms were detected at the surface layer of the GAC FAs, but their regrowth was not observed. MicroLog systems were used to identify the bacteria community distribution. Eight genera and 14 species, including Pseudomonas spp., were detected in WTP B, and 8 genera and 9 species, including Aeromonas spp., in WTP S. Further studies are required to elucidate their role in the biofilms in water treatment processes.

Biofilms and their Activity in Granular Activated Carbons Established in a Drinking Water Treatment Plant (정수장 활성탄 여과지의 생물막과 그 활성도)

  • Lee, Ji-Young;Kim, Se-Jun;Chung, Ik-Sang;Joh, Gyeong-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.6
    • /
    • pp.661-674
    • /
    • 2010
  • Bacterial biomass and its activity were measured in two kinds of granular activated carbon (GAC), the experimental and existing biofiltration system in a drinking water plant. The bacterial biomass was around 210 to 250 nmol P/g WW with phospholipid concentration at acclimation of ozonation treatment. The phospholipid biomass shows more or less a declining gradient along filter depth and no clear seasonality in its values. On the other hand, the microbial activity of [$^3H$]-thymidine and [$^{14}C$]-acetate incorporation within cells increased significantly along the filter depth, showing the difference of three fold between the upper and bottom layer. These factors support the different microbial composition or metabolic activity along the depth of GAC column. Turnover rates, the rate of bacterial biomass and production of biofilm, ranged from 0.26 /hr to 0.37 /hr, indicating a highly rapid recovery itself at amature state. In the non-ozonation treatment, the bacterial biomass was lower than in the ozonation and biological activity also declined towards the filter depth. The biomass levels during cessation of ozonation in the existing GAC filters were 68% of the actively ozonated state.

Machine Tool Error Compensation by using Measuring Plates (측정플레이트를 이용한 공작기계 오차보정)

  • 양종태;정성종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.187-192
    • /
    • 1993
  • Thermal deformation causes large amount of machine tool errors. In order to compensate for thermal and geometric errors of the machine tool an off-line geometric adaptive control (GAC) scheme was developed. THe GAC method was realized by using a measuring plate made of precision spheres. Error vectors and volumetric errors were measured by the measuring plate. Error compensation models were obtained from error vectors and a kinematic chain of machine tools. Reliability of the GAC system of thermal and geometric errors were confrimed by large amount of experiments.

  • PDF