Bacterial regrowth in biofilms formed in granular activated carbon filter adsorbers and the bacterial isolation and identification

입상 활성탄 여과지에서 세균의 재성장과 생물막 형성 세균의 분리 및 동정

  • 이규철 (한국수자원공사 수자원연구원 수돗물분석연구센터) ;
  • 권순복 (한국수자원공사 수자원연구원 수돗물분석연구센터) ;
  • 이병기 (한국수자원공사 수자원연구원 수돗물분석연구센터) ;
  • 박종근 (대구대학교 사범대학 환경교육과)
  • Received : 2008.01.10
  • Accepted : 2008.03.12
  • Published : 2008.04.15

Abstract

This study aimed to investigate the biofilm formation, bacterial regrowth, and bacterial community structure in the granular-activated carbon (GAC) filter adsorbers (FAs) used in water treatment plants. In 2005 and 2006, raw water, settled water, GAC FA by depth, and filtered water were collected twice a year from water treatment plants (WTPs) B and S. The number of heterotrophic bacteria, including mesophilic and psychrophilic bacteria, in such collected waters was investigated along with the total number of coliforms therein. Heterotrophic bacteria were detected in most samples, mainly at the surface layers of the GAC FAs, and fewer such bacteria were found in the lower and bottom layers. An increase in the bacterial number, however, was observed in the samples from various depths of the GAC FAs in WTPs B and S compared with the surface layers. An increase in the bacterial number was also detected in the filtered water. This may indicate that there is a regrowth of the bacteria in the GAC FA. Considering, however, that heterotrophic bacteria were not found in the filtered water, it can be deduced that most bacteria are removed in the chlorination process. Coliforms were detected at the surface layer of the GAC FAs, but their regrowth was not observed. MicroLog systems were used to identify the bacteria community distribution. Eight genera and 14 species, including Pseudomonas spp., were detected in WTP B, and 8 genera and 9 species, including Aeromonas spp., in WTP S. Further studies are required to elucidate their role in the biofilms in water treatment processes.

Keywords

Acknowledgement

Supported by : 한국수자원공사

References

  1. 강용태, 송근관 (2005) 생물막여과공정의 기질제거 및 전처리 특성에 관한 연구, 한국수처리학회지, 13(3), pp. 9-19
  2. 문성민, 윤제용 (2007) 배.급수관망에서 생물막 제어, 물환경학회지, 23(10), pp. 1-11
  3. 박성주, 조재창, 김상종 (1993) 상수도계통에서의 세균분포 및 변화, 미생물학회지, 31(3), pp. 245-254
  4. 이규철, 이희숙 (2006) 한국 지표수에서 수인성 장관계 바이러스에 대한 지표 미생물로서 총 대장균군과 분원성 대장균군, 상하수도학회지, 20(6), pp. 885-892
  5. 이동근 (2007) 수돗물속 생물막 형성의 초기 세균, 한국환경보건학회지, 33(5), pp. 428-433 https://doi.org/10.5668/JEHS.2007.33.5.428
  6. 한진희, 권민, 한종훈, 윤주환, 남해욱, 고주형 (2007) 반류수처리를 위한 현장 pilot plant 생물막 아질산화 반응조에서 운전인자 평가, 한국물환경학회지, 23(5), pp. 636-641
  7. 환경부 (2002) 먹는물수질공정시험방법. 환경부 고시 제2002-91호
  8. Camper, A.K., Jones, W.L. and Hayes, J.T. (1996) Effect of growth conditions and substratum composition on the persistence of coliforms in mixed population biofilms, Appl. Environ. Microbiol., 62(11), pp. 4014-4018
  9. Cappuccino, J.G. and Sherman, N. (2002) Microbiology, a Laboratory Manual. 6th Ed. p. 63-66, Benjamin/Cummings, San Francisco, CA
  10. Geldreich, E.E. and Rice, E.W. (1987) Significance and detection of Klebsiella in water systems, J. Am. Water Works Assoc., 79(5), pp. 74-80
  11. Ho, L., Hoefel, D., Bock, F., Saint, C.P. and Newcombe G. (2007) Biodegradation rates of 2-methylisoborneol (MIB) and geosmin through sand filters and in bioreactors, Chemosphere, 66(11):2210-2218 https://doi.org/10.1016/j.chemosphere.2006.08.016
  12. Hope, C.K. and Bott, T.R. (2004) Laboratory modelling of manganese biofiltration using biofilms of Leptothrix discophora, Water Res., 38(7), pp. 1853-1861 https://doi.org/10.1016/j.watres.2003.12.031
  13. LeChevallier, M.W, Lowry, C.D. and Lee, R.G. (1990) Disinfecting biofilms in a model distribution system, J. Am. Water Works Assoc., 82(7), pp. 87-94
  14. Lee, D.G. and Kim, S.J. (2003) Bacterial species in biofilms cultivated from the end of the Seoul water distribution system, J. Appl. Microbiol., 95(2), pp. 317-324 https://doi.org/10.1046/j.1365-2672.2003.01978.x
  15. Lee, D.G. Lee, J.H. and Kim, S.J. (2005) Diversity and dynamics of bacterial species in a biofilm at the end of the seoul water distribution system, World J. Microbiol. Biotechnol., 21(2), pp. 155-162 https://doi.org/10.1007/s11274-004-2890-0
  16. Magic-Knezev, A. and van der Kooij, D. (2004) Opitimisation and significance of ATP analysis for measuring active biomass in granular activated carbon filter used in water treatment, Water Res., 38(18), pp. 3971-3979 https://doi.org/10.1016/j.watres.2004.06.017
  17. Percival, S.L., Walker, J.T. and Hunter, P.R. (2000) Microbiological aspects of biofilms and drinking water. p. 61, CRC press LLC, Boca Raton, FL
  18. Velten, S., Hammes, F., Boller, M. and Egli, T. (2007) Rapid and direct estimation of active biomass on granular activated carbon through adenosine triphosphate (ATP) determination, Water Res., 41(9), pp. 1973-1983 https://doi.org/10.1016/j.watres.2007.01.021