• Title/Summary/Keyword: GaAlAs laser

Search Result 119, Processing Time 0.026 seconds

The Immediate Effects of 975-nm GaAlAs Low-level Laser Therapy on Myofacial Triger Point of Upper Trapezius Muscle in Subjects with Rounded Shoulder Posture (둥근 어깨 자세를 가진 자의 등세모근 위 섬유의 압통점에 975-nm GaAlAs 저출력레이저 적용에 대한 즉각적인 효과)

  • Kim, Byeong-Jo;Lee, Jung-Hoon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.4
    • /
    • pp.433-438
    • /
    • 2014
  • PURPOSE: The purpose of our study was to compare a 975-nm, 500-mW GaAlAs low-level laser therapy versus placebo low-level laser therapy with regard to the immediate changes on the myofascial trigger point of the dominant upper trapezius muscle in subjects with rounded shoulder posture. METHODS: Thirty-two male college students with rounded shoulder posture and shoulder pain consented to participate in the experiment. The subjects were randomly assigned to a 2-minute procedure with either an active GaAlAs low-level laser or a placebo GaAlAs low-level laser. The pressure-pain threshold and visual analog scale on tenderness at 3 kg were measured with an algometer before and after the laser treatments. RESULTS: The active GaAlAs low-level laser group showed significant changes in pressure-pain threshold and visual analog scale on tenderness at 3 kg (p<0.05). The placebo GaAlAs low-level laser group showed no significant changes in either pressure-pain threshold or visual analog scale on tenderness at 3 kg (p>0.05). CONCLUSION: An immediate effect was observed in pressure-pain threshold and visual analog scale on tenderness at 3 kg following a 2-minute application ($857.14J/cm^2$) of a 975-nm, 500-mW GaAlAs low-level laser to the myofascial trigger point of the dominant upper trapezius muscle in patients with rounded shoulder posture.

The Effect of Low Power Laser Irradiation on acute pain of Rats Induced by Wound (저강도 레이저가 흰쥐 창상 후 급성통증에 미치는 영향)

  • Kim Dong-Hyun;Baek Su-Jeong;Kim Suk-Bum;Song Ju-Min;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.2
    • /
    • pp.234-249
    • /
    • 2002
  • This study was performed, using c-fos and Substance P, to investigate the effect of GaAlAs laser on acute pain model induced by wound in lumbar region's spinal level. The test group was divided into control and experimental group. Control group is shamed group(c-fos and substance P expression after non-irradiation by a GaAlAs laser), The experimental group was divided into two subgroups: one is experimental group I (c-fos expression after irradiation by a GaAlAs laser), and the other is experimental group II (substance P expression after irradiation by a GaAlAs laser). The results of this study were as following: 1. The numbers of c-fos immunoreactive neuron in spinal cord was increased markedly 1 day after wound, and decreased gradually from 1 day to 2 days in wound with GaAlAs laser irradiation. 2. The changes of the average percentages of substance P immunoreactive neurons in spinal cord was increased markedly 1 day after wound, and decreased gradually from 1 day to 2 days in wound with GaAlAs laser irradiation. Therefore, decreasing the changes of c-fos and substance P expression after irradiation by a GaAlAs laser indicates and GaAlAs laser have effect on pain control.

  • PDF

Design and Simulation of an 808 nm InAlAs/AlGaAs GRIN-SCH Quantum Dot Laser Diode

  • Chan, Trevor;Son, Sung-Hun;Kim, Kyoung-Chan;Kim, Tae-Geun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.124-127
    • /
    • 2011
  • Quantum dots were designed within a GRIN-SCH(Graded index - Separate confinement Heterostructure) heterostructure to create a high power InAlAs/AlGaAs laser diode. 808 nm light emission was with a quantum dot composition of In0.665Al0.335As and wetting layer composition of Al0.2Ga0.8As by LASTIP simulation software. Typical characteristics of GRIN structures such as high confinement ratios and Gaussian beam profiles were shown to still apply when quantum dots are used as the active media. With a dot density of 1.0x1011 dots/cm2, two quantum dot layers were found to be good enough for low threshold, high-power laser applications.

A Study on the Immunohistology in Injury Cure of Rat by using InGaAlP Laser Diode (InGaAlP 레이저다이오드를 적용한 Rat의 착상 치유에서 면역조직화학적 연구)

  • Yu, Seong-Mi;Park, Yong-Pil;Cheon, Min-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.5
    • /
    • pp.431-435
    • /
    • 2009
  • The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a InGaAlP laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. The study has executed in-vivo experiment by employing our own developed laser diode irradiation system to investigate the effects of the InGaAlP laser diode irradiation on the wound healing as a preliminary study aimed at the application of InGaAlP laser diode to wound healing of human skin injury. The study cut out whole skin layers of Sprague-Dawley rat on the back part in 1 cm circle and observed developing effects after executing light irradiation for 9 days, and in result it is found that the light irradiation rat showed earlier wound healing than non-irradiation rat during the experimental period. In addition, there are some differences found regarding the healing process between laser diode irradiated rats and non-irradiated ones.

The Spectrum of Laser Instruments for Laser Acupuncture Application (레이저침 시술에 사용되는 레이저 기기의 적용 범위에 대한 고찰)

  • Hwang, Eui-Hyoung;Yang, Chang-Sop;Jang, In-Soo
    • Journal of Acupuncture Research
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2009
  • Objectives : During the past three decades there has been a significant evolution of laser acupuncture application in the nature of the clinical approach and the research of traditional medicine and laser therapy field. However, there have been no standard and guideline of laser equipment can be applied as laser acupuncture. This study aims to investigate the condition of laser equipment required as a laser acupuncture method. Methods : First, we performed literature search using the Medline(from 1999 to Oct 2008) to confirm types and ranges of laser equipments that can be applied as laser acupuncture. In addition, we investigated the characters of acupoints such as sites and depths, and compared with penetrating depths of each laser. Results : A total of 37 articles for clinical studies using laser acupuncture were selected, and 41 lasers were used. GaAs laser was used three times, GaAlAs laser 14, InGaAlP 18, HeNe laser 4, and Argon laser and CO2 laser were used one time, respectively. From all 361 points of fourteen meridians, depths of 341 points(94.5%) were 1 cun(2.3-3.2cm) or less. The mean depth of all points was 0.48 cun(1.1-1.5cm). Hence, it appeared that the majority of therapeutic lasers satisfied with the condition. HeNe, InGaAlP, GaAlAs, GaAs lasers are recommended for laser acupuncture, however, it may plausible that other surgical lasers could be used as the laser acupuncture, because it have the biostimulation effect to some extent, too. Conclusions : It is suggested that to select appropriate laser type and give the adequate output power to reach the acupoints under the skin using laser acupuncture. Further evaluation and research for the condition of laser acupuncture are warranted.

  • PDF

Improvement of AlGaAs/GaAs Quantum Well Laser Diodes by Thermal Annealing (AlGaAs/GaAs 레이저 다이오우드의 열처리에 의한 개선에 관한 연구)

  • Jung, Hyon-Pil;Kenzhou Xie;Wie, Chu-Ryang;Lee, Yun-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.3
    • /
    • pp.449-455
    • /
    • 1993
  • In order to investigate the improvements of relatively poor characteristics of short wave length AlGaAs/GaAs laser diodes which are useful as a light source for short distance communication systems, the low temperature $(<680^{\circ}C)$ grown AlGaAs/GaAs GRINSCH-QW laser diodes by molecular beam epitaxy have been studied by photoluminescence as a function of rapid thermal annealing (RTA) temperature. It is shown that guantum well photoluminescence intensity increased substantially by a factor of 10 after RAT at $950^{\circ}C$ for 10 sec. This is related to the reduction of non-radiative recombination in the guantum well region. The threshold current of annealed laser diode is reduced by a factor, of 4, confirming the improvement of laser diode quality by rapid thermal annealing.

  • PDF

Effects of GaAsAl Laser on the Pressure Pain Threshold in Rats (GaAsAl 레이저 자극이 흰쥐의 압통역치에 미치는 영향)

  • Song, Young-Wha;Lee, Young-Gu;Lim, Jong-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.533-543
    • /
    • 2000
  • This study was designed to evaluate the analgesic effect of low power GaAsAl laser on the pain threshold of mechanical stimulation using different treatment points, acupuncture point (zusanli) and non-acupuncture points(back). Furthermore, we investigated the analgesic effect of low power GaAsAl laser using the different duration and intensity of laser in mechanical stimulation induced pain behavior. The results were summarized as follows: 1. The threshold of mechanical stimulation was significantly increased by GaAsAl laser stimulation into zusanli point after 15 and 30 min after laser stimulation(P<05). However, the laser stimulation into non-acupoint did not affect the pain threshold of mechanical stimulation. with dose dependent manner. 2. In order to investigate the analgesic effects of BV depending upon different intensities of laser stimulation, the experimental animals were divided into three groups: 3 mW treated group, 6 mW treated group and 10 mW treated group. The low power GaAsAl laser stimulation was applied into zusanli acupoint for 30 min with different intensity of laser stimulation. Six and ten mW of laser stimulation significantly increased the pain threshold of mechanical stimulation at 15 min after laser stimulation as compared to that of control group(P<.05). Moreover, the analgesic effect of 10 mW laser stimulation was maintained for 30 min after laser stimulation (P<.05). 3. Finally, we tested the analgesic effect of 10 mW laser stimulation using different duration such as 10 min, 30 min or 1 hr after application of mechanical stimulation. In 30 min treatment group, the pain threshold of mechanical stimulation was increased at 15min and 30min after laser stimulation(P<.05). However, laser stimulation for 60 min dramatically increased the pain threshold of mechanical stimulation at 0 min after laser stimulation and the analgesic effect of laser stimulation was observed until 1 hr after laser stimulation. In conclusion, these data apparently demonstrate that low power GaAsAl laser has analgesic effect on mechanical induced pain model in rats. In addition, the treated point, intensity and duration of laser stimulation should be concerned before clinical application for pain management purpose.

  • PDF

Ridge Formation by Dry-Etching of Pd and AlGaN/GaN Superlattice for the Fabrication of GaN Blue Laser Diodes

  • Kim, Jae-Gwan;Lee, Dong-Min;Park, Min-Ju;Hwang, Seong-Ju;Lee, Seong-Nam;Gwak, Jun-Seop;Lee, Ji-Myeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.391-392
    • /
    • 2012
  • In these days, the desire for the precise and tiny displays in mobile application has been increased strongly. Currently, laser displays ranging from large-size laser TV to mobile projectors, are commercially available or due to appear on the market [1]. In order to achieve a mobile projectors, the semiconductor laser diodes should be used as a laser source due to their size and weight. In this presentation, the continuous etch characteristics of Pd and AlGaN/GaN superlattice for the fabrication of blue laser diodes were investigated by using inductively coupled $CHF_3$ and $Cl_2$ -based plasma. The GaN laser diode samples were grown on the sapphire (0001) substrate using a metal organic chemical vapor deposition system. A Si-doped GaN layer was grown on the substrate, followed by growth of LD structures, including the active layers of InGaN/GaN quantum well and barriers layer, as shown in other literature [2], and the palladium was used as a p-type ohmic contact metal. The etch rate of AlGaN/GaN superlattice (2.5/2.5 nm for 100 periods) and n-GaN by using $Cl_2$ (90%)/Ar (10%) and $Cl_2$ (50%)/$CHF_3$ (50%) plasma chemistry, respectively. While when the $Cl_2$/Ar plasma were used, the etch rate of AlGaN/GaN superlattice shows a similar etch rate as that of n-GaN, the $Cl_2/CHF_3$ plasma shows decreased etch rate, compared with that of $Cl_2$/Ar plasma, especially for AlGaN/GaN superlattice. Furthermore, it was also found that the Pd which is deposited on top of the superlattice couldn't be etched with $Cl_2$/Ar plasma. It was indicating that the etching step should be separated into 2 steps for the Pd etching and the superlattice etching, respectively. The etched surface of stacked Pd/superlattice as a result of 2-step etching process including Pd etching ($Cl_2/CHF_3$) and SLs ($Cl_2$/Ar) etching, respectively. EDX results shows that the etched surface is a GaN waveguide free from the Al, indicating the SLs were fully removed by etching. Furthermore, the optical and electrical properties will be also investigated in this presentation. In summary, Pd/AlGaN/GaN SLs were successfully etched exploiting noble 2-step etching processes.

  • PDF

Improved Uniformity of GaAs/AlGaAs DBR Using the Digital Alloy AlGaAs Layer (디지털 합금 AlGaAs층을 이용하여 제작된 GaAs/AlGaAs DBR의 균일도 향상)

  • Cho, N.K.;Song, J.D.;Choi, W.J.;Lee, J.I.;Jeon, Heon-Su
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.280-286
    • /
    • 2006
  • A distributed Bragg reflector (DBR) for the application of $1.3{\mu}m$ vertical cavity surface emitting laser (VCSEL) has grown by digital-alloy AlGaAs layer using the molecular beam epitaxy (MBE) method. The measured reflection spectra of the digital-alloy AlGaAs/GaAs DBR have uniformity in 0.35% over the 1/4 of 3-inch wafer. Furthermore, the TEM image showed that the composition and the thickness of the digital-alloy AlGaAs layer in AlGaAs/GaAs DBR was not affected by the temperature distribution over the wafer whole surface. Therefore, the digital-alloy AlGaAs/GaAs DBR can be used to get higher yield of VCSEL with the active medium of InAs quantum dots whose gain is inhomogeneously broadened.