• Title/Summary/Keyword: GS-3K8

Search Result 97, Processing Time 0.043 seconds

Effect of Black Garlic and Gaeddongssuk (Artemisia annua L.) Extracts on the Lipid Profile and Hepatic Antioxidant Enzyme Activities of Exercised Rats (흑마늘 및 개똥쑥 추출물의 급이가 강제운동 시 흰쥐의 체내 지질 성분 및 간조직의 항산화효소 활성에 미치는 영향)

  • Kang, Jae-Ran;Lee, Soo-Jung;Hwang, Cho-Rong;Kim, In-Sung;Sung, Nak-Ju
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.6
    • /
    • pp.869-876
    • /
    • 2013
  • To develop functional products based on black garlic, a black garlic extract (BG) of 7 brix, a gaeddongssuk extract (GS) of 0.7 brix and two types of mixtures (MBS-I, black garlic 7 brix : gaeddongssuk 0.7 brix; MBS-II, black garlic 14 brix : gaeddongssuk 1.4 brix, 93:7, v/v) were supplemented to rats training on a treadmill for 4 weeks. Body weight from the training did not decrease during the experimental period. Serum albumin content significantly increased in the groups fed an experimental diet compared to the control. The BUN content significantly decreased in BG and MBS-II groups compared to the control. AST and ALP activities significantly decreased in the groups fed an experimental diet compared to the control. Serum triglyceride and total cholesterol levels in MBS-I and MBS-II groups significantly decreased compared to the control. Lipid levels in the serum and liver tissue were not significantly different between the MBS-I and MBS-II groups. The lipid peroxide content in the serum and liver tissue was significantly reduced in the groups fed all extracts compared to the control; the serum and liver lipid contents was lowest in the MBS-I and MBS-II groups, respectively. Hepatic catalase activity in the GS and MBS groups increased by 1.8~2.3 times compared to the control. SOD and GSH-px activities significantly increased from treatment with the extracts by 1.3~1.5 times and 1.2~1.7 times, respectively. These results indicate that a mixture of BG and GS extracts has higher biological activity than a single supplementation of BG or GS extract. Therefore, the addition of gaeddongssuk to black garlic (MBS-I and MBS-II) is effective as a defense material against oxidative stress. MBS-I may be especially effective for its biological activities.

Studies on the EPA(eicosapentaenioc acid) production by marine bacteria (해양세균(海洋細菌)을 이용(利用)한 EPA(eicosapentaenoic acid) 생성(生成)에 관한 연구(硏究))

  • Joh, Yong-Goe;Kim, Seong-Jin;Kim, Ji-Soo;Lee, Min-Kyeng
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.121-130
    • /
    • 1995
  • This project has been worked out for isolation of EPA-producing bacteria from marine source of sea water, sea sediment and intestinal contents eviscerated from some red-muscle fish such as mackerel, horse-mackerel and spike fish. The samples were precultured on the media of PPES-II glucose broth and then pure-cultured on Nutrient agar and P-Y-M glucose. Lipids extracted from those bacterial mass collected by centrifugation were analysed in terms of lipid class and fatty acid composition. The results are resumed as follows : 1. 112 strains from sea water and 76 strains from sea sediment were tested for their EPA producing capability, but both strains of (SA-67 and SA-91) from the former and four strains(SS-35, 37, 51 and 71) from the latter have been proved to produce EPA above the level of 2% of total fatty acids. The strains such as GS-11, 29, 31, HM-9, 29, B-18, 33, 107, YL-129, 156, 203, 77, 104 and 256 which were isolated from fish intestinal contents, have also produced EPA at higher level than 2% of total fatty acids. 2. Contents of total lipids extracted from the cultures of these strains grown at $25^{\circ}C$, range from 2.8% to 6.9% (on dry weight %), and they are mainly composed of polar lipids($40.9{\sim}52.9%$) such as phosphatidyl glycerol($^{+}cardiolipin$)(?) and phosphatidyl ethanolamine ($33.8{\sim}40.0%$), with smaller amount of free fatty acid ($11.2{\sim}20.2%$). 3. EPA was isolated from a mixture of fatty acid methyl esters obtained from the lipid of each strain by HPLC in silver-ion mode and was identified by GC-Mass spectrometry. 4. The strains of SW-91, GS-11, GS-29, HM-9, B-18 and YL-203 grown at $25^{\circ}C$ have a level of 5% EPA in their total fatty acids, and the GS-11 and HM-9 strains show a tendency of increase in the EPA level with an increase of growth temperature.

Displayed Subjects of Practice and Case-Mix of Private Practitioners in Taegu City (개원의의 진료과목표방 및 진료환자 구성)

  • Park, Jae-Yong;Oh, Kang-Jin;Kam, Sin
    • Health Policy and Management
    • /
    • v.2 no.1
    • /
    • pp.42-65
    • /
    • 1992
  • To survey the specialties or sujects of practice displayed by the private practitioners the authors visited 691 clinics in Taegu from April 1 to May 18, 1991, At the same time, a mail questionnaire was administered to ask the number of displayed subjects of practice, and the reasons for displaying the subjects, reasons for not displaying in case of no specialty was displayed, composition of patients, and role as a specialist. The questionnaire was returned by 308(44.6%) practitioners. The distributions of private practitioners by specialty were 13.9% for internal medicine (IM), 11.7% for pediatrics(Ped), 13.0% for obstetrics '||'&'||' gynecology(OBGY), 11.1% for general surgery(GS), 10.0% for family practice(FP), and 5.3% for general practitioner(GP). Ninety percent of the specialists have displayed their specialty in their offices. Among all the private practitioners, 61.9% of them have displayed their subjects of practice and 23.7% have shown telephone number. Among private practitioners who displayed the subjects of practice, 80.6% have signs of 'subjects of practice'. Mean number of the displayed subjects of practice for the all private practitioners is 1.20, and 1.93 for the private practitioners who displayed subjects of practice. FP and GS have displayed their subjects of practice in 91.2% and 87.0% respectively and OBGY have displayed in 32.2%, the lowest percentage among all the soecuaktues. IM specialists displays pediatrics as a major subject of practice in 72.1% the pediatricians display IM in 88.9% the OBGYs display pediatrics in 77.8%, and the GSs display IM in 51.9%. Most commonly displayed subjects of practice are Ped and IM. Sixty-five percent of the private practitioners answered that they don't display their specialties because their clinics are "primary health care facility". The reasons for displaying the subjects of practice and its relevance with their own specialty(45.6%), and the difficulty in clinic management only with the patients for their own specialty(36.9%). The proportion of clinics whose patients of other specialty are than their own specialty accounted less than 10% was 52.8% and that accounted more than 51% was 16.0%. Specially, 51.4% of GS specialists cared more than 51% of patients of other specialty area than their own specialty. Most of the patients of IM, Ped, and OBGY specialists are the patients of their own specialty. However, 56.8% of GS care more of IM patients and only 24.3% of them care mostly GS patients, The respondents to the mail questionnaire who stated that they can not play the role of specialist well are 30.5% and especially 72.9% of the GS specialists state so. The proportion of respondents who do not suffort the private practice of specialists is 71.1%. Among the surgical specialists, 82.7% of them rarely perform operation. The reasons for not performing operation are insufficient insurance fee (76.9%), and risk of operation(58.0%), so as the OBGY specialists. Above finidngs suggest that most of the specialists, especially surgeons, in the private practice can not play their role as a specialist. It is necessary to develop a policy that facilitates the production of practice and the retention of the specialists in the hospitals.s.

  • PDF

Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading (섬유혼입공법을 적용한 고강도콘크리트 기둥의 재하 내화시험)

  • Youm, Kwang-Soo;Jeon, Hun-Kyu;Kim, Heung-Youl
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.4
    • /
    • pp.473-480
    • /
    • 2009
  • The 180 minutes fire test based on the standard curve of ISO-834 were conducted on three RC column specimens with different constant axial loading ratios to evaluate the fire performance of fiber cocktail (polypropylene+steel fiber) reinforced high strength concrete column. The columns were tested under three loading levels as 40%, 50%, and 61% of the design load. No explosive spalling has been observed and the original color of specimen surface has been changed to light pinkish grey. The maximum axial displacements of three specimens were 1.5~2.2 mm. There was no reduction in load bearing capacity of each specimen exposed to fire and no effect were observed on the fire performance within 61% of the design load. The tendencies of the results with loading, such as the temperature distribution of in concrete and the changes in temperature rise due to the water vaporization in concrete, are very similar to those without loading. The final temperatures of steel rebar after 180 minutes of fire test resulted in 491.4${^{\circ}C}$ for corner rebar, 329.0${^{\circ}C}$ for center rebar, and 409.8${^{\circ}C}$ for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 153.7${^{\circ}C}$ㅍ. The tendency of temperature rise in concrete and steel rebar changed after 30~50 minutes from the starting time of the fire test because the heat energy influx into corner rebar is larger than that into center rebar. The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.

Flow Characteristics of Ejector Driven Pipe According to the Changes of Diameter Ratio and End Position (이젝터 구동관로의 직경비와 끝단의 위치 변화에 따른 유동특성)

  • Kim, Noh Hyeong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • This study conducted CFD analysis on the mean velocity vector of distribution of the ejector driven pipe while changing the inlet velocity to 1 m/s at the diameter ratio of diffuser of 1:3, 1:2.25, 1:1.8 with the end position of driven pipe at 1, 1.253, 1.333, 1.467 respectively, which used $k-{\varepsilon}$/High Reynolds Number for the turbulence model, SIMPLE method for the analysis algorithm, and PIV experiment to verify the CFD analysis. As a result of the CFD analysis the optimum diameter ratio of ejector driven pipe was 1:3, the optimum end position of driven pipe was 1.333 for the diameter ratio of 1:3, 1:2.25, 1:1.8 and the PIV experiment obtained the same result as the CFD analysis. Therefore, the numerical analysis of the flow characteristics of ejector can be used for the optimum design implementation on ejector system.

Assessment of Nutritional Status before TPN Support of Hospitalized Patients (입원환자의 TPN 투여전 영양상태 평가)

  • Park, Hyoung-Sook;Lee, Soo-Kyeong;Ha, Mi-Jeong
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.9 no.2
    • /
    • pp.69-77
    • /
    • 2002
  • The purpose of this study was to assessment of hospitalized patients. Nutritional assessment was performed on 353 hospitalized patients before TPN support by ideal body weight. albumin, total lymphocyte count, cholesterol. The data analysis were performed on frequency, percentage, means and standard deviation. The major findings as follows: 1. Everage NPO duration was $6.77\pm5.39$day and $\geq5$days 48.9%, >5days 51.1%. NPO duration of 1M, NL, GS, Others prolonged. 2. %IBW was everge $94.86\pm17.21%$ 43.1% normal. 37.8% low weight. There were low weight IM 44.8%. TS 47.8%, Others 44.0%. 3. Albumin was everage $2.93\pm0.51$g/dl. moderate malnutrition 45.4%, mild malnutrition 30.9%. All session were malnutrition status. 4. Total lymphocyte count was ever age $960.41\pm721.32cell/mm^2$. severe malnutrition 43.9%. moderate malnutrition 29.0%, mild malnutrition 24.4%, normal 2.7%. All session were malnutrition status. 5. Cholesterol was everage $123.02\pm45.67$mg/dl 58.4% low level. 41.2% normal. 0.4% high level. 1M, GS and TS were low level. NL, NS, DR, Others were normal. It was very poor nutritional status before TPN support of patients. The malnutrition decrease immunity, slowly cure injury, cause abnormality organs, increase the complication and obstruct the recovery. Therefore, Evaluating and correcting are very important.

  • PDF

Effect of Far-Infrared Irradiation on the Antioxidant Activity of Extracts from Grape Seed (포도씨의 항산화능에 대한 원적외선 처리의 효과)

  • Jeong, Seok-Moon;Kim, So-Young;Ha, Jung-Uk;Lee, Seung-Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.10
    • /
    • pp.1619-1624
    • /
    • 2005
  • The effect of far-infrared (FIR) irradiation on the antioxidant activity of extracts from grape seed (GS) was evaluated. GS (5 g) were placed in Pyrex petri dishes (8.0 cm diameter) md FIR irradiated at 150$^{\circ}C$ for 10, 20, 30, 40 or 60 min with a FIR heater. After FIR irradiation, water extract (WE) (1.0 g/10 mL), methanol extract (ME) (1.0 g/10 mL) and 70$\%$ ethanol extract (EE) (1.0 g/10 mL) of GS were prepared, and total phenol contents (TPC) and radical scavenging activity (RSA) of the extracts were determined. The antioxidant activities of GS extracts increased as FIR irradiation. For example, FIR irradiation of GS at 150$^{\circ}C$ for 10 min increased the TPC and RSA of WE from 0.95 mM to 1.84 mM and 33,87$\%$ to 58.55$\%$, respectively, compared to non-irradiated control. In the case of ME at the same conditions of FIR irradiation (150$^{\circ}C$ for 10 min), the TPC and RSA also increased from 3.4 mM to 4.52 mM and 76.55$\%$ to 89.41$\%$, respectively. The TPC and RSA of EE increased from 2.65 mM to 4.82 mM and 66.89$\%$ to 84.62$\%$, too. According to the GC/MS analysis, several low-molecular-weight phenolic compounds such as vanillic acid and 3,4-hydroxy benzoic acid were newly formed in the EE after FIR irradiated at 150$^{\circ}C$ for 10 min. There were slight differences in the kinds of phenolic compounds between EE of non irradiated control and FIR irradiated samples. These results indicated that FIR irradiation onto GS could enhance antioxidant activities of its extracts with increasing the amount of phenolic compounds.

Effects of Fermented Feedstuff with Wet Brewer’s Grain and Soybean on Fattening Performance and Carcass Grade in hanwoo Steers (맥주박 발효사료 및 대두의 급여가 한우 거세우의 육성성적 및 도체등급에 미치는 영향)

  • Park, B.K.;Gil, J.M.;Kim, J.B.;Hong, B.J.;Ra, C.S.;Shin, J.S.
    • Journal of Animal Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.397-408
    • /
    • 2003
  • This study was conducted to examine the feeding effects of FFWBG (fermented feedstuff with wet brewer’s grain) and GS(grinding soybean) in Hanwoo steers. For this research, total twenty steers(average body weight : 455.7$\pm$25.9kg) were grouped into control(formula feed), T1(formula feed:FFWBG=60:40), T2(formula feed:GS=80:20), T3(formula feed:FFWBG:GS=50:40:10), and T4(formula feed: FFWBG:GS=40:40:20), each treatment was allocated to four steers. There was a tendency to be increased average daily gain in T1, T2, T3 and T4 compared with the control even though no statistical significance was found. The feed conversion of T1, T2, T3 and T4 were beneficially better than that of control(P<0.05; 8.25, 9.44, 6.69 and 7.71 vs 11.90, respectively). The blood urea nitrogen concentration of T4 was higher than that of control(P<0.05), but the creatinine concentration of T4 was lower than that of control(P<0.05). The glucose concentration of T1, T2, T3 and T4 were higher than that of control(P<0.05; 59.39, 62.44, 62.17 and 54.00 vs 51.00mg/$d\ell$, respectively). The back-fat thickness of T3 was thicker than that of control, T1, T2 and T4. The rib-eye area of T1, T3 and T4 was wider than that of control. Appearances percentage of ‘A’ ranked meat quantity were 66, 33, 75 and 33% in control, T1, T2 and T4, respectively.

8kW LLC Isolated Converter Design for ESS Battery Charge/Discharge System (ESS 배터리 충방전 시스템을 위한 8kW급 LLC 절연형 컨버터 설계)

  • Kim, Jinwoo;Baek, Seunghoon;Cho, Younghoon;Koo, Tae-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.161-167
    • /
    • 2018
  • In battery-operated systems, an isolated converter is used to interface the utility grid with the system to increase stability when charging and discharging batteries. Systems such as vehicle-to-grids (V2Gs), on-board chargers, and energy storage systems (ESSs) have recently become popular, and the roles of isolated converters have become important considerations in fabricating such devices. A fixed-frequency LLC converter, which is a type of isolated converter, presents the advantages of high efficiency and high power density by performing zero-voltage switching (ZVS) over wide frequency ranges. However, the magnetizing inductance of the LLC converter should be designed to enable ZVS in all switching devices. Therefore, in this study, the operating characteristics of the LLC circuit are analyzed, and an optimal design method for ZVS operation is established. Moreover, an 8 kW LLC high-efficiency and high-power-density resonant converter is designed and tested for ESS application. The LLC converter achieves 98% efficiency at rated power.

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.