• Title/Summary/Keyword: GRID

Search Result 9,461, Processing Time 0.032 seconds

A Study on Transient Operation Characteristics of 30kW Scale CVCF Inverter based Micro-grid (30kW급 CVCF 인버터 기반 Micro-grid의 구현 및 과도상태 운용특성에 관한 연구)

  • Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Park, Ji-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.18-25
    • /
    • 2019
  • Recently, micro-grids based on a CVCF inverter have been replacing diesel generators to reduce CO2 emissions in island areas with the increase of renewable energy sources. Stable operation methods are also being researched. These micro-grids may cause energy sinking if the total output of renewable energy sources is larger than the total customer loads. In the case of energy sinking, the voltage of a CVCF battery could rapidly increase according to the condition of SOC, and blackout could occur in the micro-grid due to the operation of a protection device in a CVCF inverter. Therefore, this paper analyzes the operation characteristics of a CVCF-inverter-based micro-grid when energy sinking occurs and proposes a transient operation strategy to prevent shut-down of the CVCF inverter. A test device of a 30-kW CVCF-inverter-based micro-grid was implemented, and the transient operation characteristics for the energy sinking phenomenon are presented. The simulation results confirm that blackout can be properly prevented according to the conditions of SOC and voltage in a CVCF battery.

A Comparative Study on the Different Usage of the Grids between Leonardo da Vinci and J.N.L. Durand (레오나르도 다 빈치와 J.N.L. 뒤랑의 그리드 사용법에 관한 비교 연구)

  • Hwang, Minhye
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.8
    • /
    • pp.189-199
    • /
    • 2017
  • The purpose of this study is to compare the grid usage that is common to Leonardo da Vinci and J.N.L. Durand in the process of designing the architectural plan. In the days when there was no proper measurement tool, auxiliary lines relied entirely on the architect's personal mindset and design convenience. Therefore, it is considered that studying the auxiliary lines drawn by the architects will be useful for studying the human perception system. Among auxiliary lines, the grid has been used by many architects. Leonardo da Vinci and J.N.L. Durand are famous. However, these two show a significant different grid usage. As auxiliary grid and space ares added the center of the Leonardo da Vinci grid continues to move, and the grid in his sketch is becoming a building space itself. So I call it 'conceptual grid'. In the case of J.N.L. Durand, the one center of the grid is always at the center of the drawing. That is, all the positions of the grid can be determined in phase around a common point, and all of the same specifications are assumed. The grid is a kind of filter. That's why his grid is a visual abstraction of the process of thinking. In this paper, I will call the grid of J.N.L. Durand as 'abstract grid'.

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.

Self-Adaptive Smart Grid with Photovoltaics using AiTES (AiTES를 사용한 태양광 발전이 포함된 자가 적응적 스마트 그리드)

  • Park, Sung-sik;Park, Young-beom
    • Journal of Platform Technology
    • /
    • v.6 no.3
    • /
    • pp.38-46
    • /
    • 2018
  • Smart Grid is an intelligent power grid for efficiently producing and consuming electricity through bi-directional communication between power producers and consumers. As renewable energy develops, the share of renewable energy in the smart grid is increasing. Renewable energy has a problem that it differs from existing power generation methods that can predict and control power generation because the power generation changes in real time. Applying a self-adaptative framework to the Smart Grid will enable efficient operation of the Smart Grid by adapting to the amount of renewable energy power generated in real time. In this paper, we assume that smart villages equipped with photovoltaic power generation facilities are installed, and apply the self-adaptative framework, AiTES, to show that smart grid can be efficiently operated through self adaptation framework.

Development of a Grid-based Framework for High-Performance Scientific Knowledge Discovery (그리드 기반의 고성능 과학기술지식처리 프레임워크 개발)

  • Jeong, Chang-Hoo;Choi, Sung-Pil;Yoon, Hwa-Mook;Choi, Yun-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.877-885
    • /
    • 2009
  • In this paper, we propose the SINDI-Grid which is a high-performance framework for scientific and technological knowledge discovery using the grid computing. By using the advantages of the grid computing providing data repository of large-volume and high-speed computing power, the SINDI-Grid framework provides a variety of grid services for distributed data analysis and scientific knowledge processing. And the SINDI-Workflow tool exploits these services so that performs the design and execution for scientific and technological knowledge discovery applications which integrate various information processing algorithms.

A Grid Adaptation Method Using the Chimera and Patched Grid Systems (중첩격자계와 접합격자계를 이용한 적응격자 기법)

  • Kim, De-Hee;Kwon, Jang-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.10
    • /
    • pp.17-25
    • /
    • 2005
  • A grid adaptation method within systems of chimera and patched grids is presented. Problem domains are divided into near-body and off-body fields. Near-body field is filled with curvilinear body-fitted grids that extend only a short distance from body surfaces and connected to other grid systems via chimera domain connectivity method. Off-body field is filled with patched uniform cartesian grids of varying levels of refinement. This method gives flexibility in grid generation and efficient adaptation capability. Several numerical experiments including 2D store separation were performed to show the performance of the proposed adaptation method.

Turbulent Flow Simulations on 2-Dimensional Ground Effect Part I. Verification on the Overlap Grid Method (2차원 지면 효과에 대한 난류 유동장 해석 Part I. 중첩 격자 기법 적용에 대한 연구)

  • Kim, Yoon-Sik;Lee, Jae-Eun;Kim, Eu-Gene;Kwon, Jang-Hyuk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.8
    • /
    • pp.661-669
    • /
    • 2007
  • Study on the feasibility assessment for applying the overlap grid method to numerical calculations on the ground effect has been performed. The objective of the present study is to settle the problem in the grid generation process. A low Mach number preconditioned turbulent flow solver using the overlap grid and the multi-block grid methods has been developed and applied to the ground effect simulation around the RAE 101 airfoil. It has been verified that the overlap grid method not only can provide sufficiently accurate solutions but also work out the grid generation problem in the ground effect simulations.

New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S.;Jain, Praveen K.;Nishith, Goel
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.10-22
    • /
    • 2008
  • The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.

Power Quality Improvement for Grid Connected Inverters under Distorted and Unbalanced Grids

  • Kim, Hyun-Sou;Kim, Jung-Su;Kim, Kyeong-Hwa
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1578-1586
    • /
    • 2016
  • A power quality improvement scheme for grid connected inverters, even in the presence of the disturbances in grid voltages due to harmonic distortions and three-phase imbalance, is presented for distributed generation (DG) power systems. The control objective is to force the inverter currents to follow their references with robustness even under external disturbances in grid voltages. The proposed scheme is realized by a disturbance observer (DOB) based current control scheme. Since the uncertainty in a system can be effectively canceled out using an estimated disturbance by the DOB, the resultant system behaves like a closed-loop system consisting of a disturbance-free nominal model. For experimental verification, a 2 kVA laboratory prototype of a grid connected inverter has been built using a digital signal processor (DSP) TMS320F28335. Through comparative simulations and experimental results under grid disturbances such as harmonic distortion and imbalance, the effectiveness of the proposed DOB based current control scheme is demonstrated.

The Design and Implementation of an Available Bandwidth Measurement Scheme in the K*Grid System

  • Hahm, Seong-Il;Cho, Seong-Ho;Choi, Han;Kim, Chong-Kwon;Lee, Pill-Woo
    • Journal of Information Processing Systems
    • /
    • v.2 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • Grid computing is an emerging technology that enables global resource sharing. In Korea, the $K^*$Grid provides an extremely powerful research environment to both industries and academia. As part of the $K^*$Grid project, we have constructed, together with the Korea Institute of Science and Technology Information and a number of domestic universities, a supercomputer Grid test bed which connects several types of supercomputers based on the globus toolkit. To achieve efficient networking in this Grid testbed, we propose a novel method of available bandwidth measurement, called Decoupled Capacity measurement with Initial Gap (DCIG), using packet trains. DCIG can improve the network efficiency by selecting the best path among several candidates. Simulation results show that DCIG outperforms previous work in terms of accuracy and the required measurement time. We also define a new XML schema for DCIG request/response based on the schema defined by the Global Grid Forum (GGF) Network Measurement Working Group (NM-WG).