• 제목/요약/키워드: GRE

검색결과 101건 처리시간 0.022초

Whole Genome Analysis of Human Papillomavirus Type 16 Multiple Infection in Cervical Cancer Patients

  • Chansaenroj, Jira;Theamboonlers, Apiradee;Junyangdikul, Pairoj;Swangvaree, Sukumarn;Karalak, Anant;Poovorawan, Yong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권2호
    • /
    • pp.599-606
    • /
    • 2012
  • The characterization of the whole genome of human papillomavirus type 16 (HPV16) from cervical cancer specimens with multiple infections in comparison with single infection samples as the oncogenic potential of the virus may differ. Cervical carcinoma specimens positive for HPV16 by PCR and INNO-LiPA were randomly selected for whole genome characterization. Two HPV16 single infection and six HPV16 multiple infection specimens were subjected to whole genome analysis by using conserved primers and subsequent sequencing. All HPV16 whole genomes from single infection samples clustered in the European (E) lineage while all multiple infection specimens belonged to the non-European lineage. The variations in nucleotide sequences in E6, E7, E2, L1 and Long control region (LCR) were evaluated. In the E6 region, amino acid changes at L83V were related to increased cancer progression. An amino acid variation N29S within the E7 oncoprotein significantly associated with severity of lesion was also discovered. In all three domains of the E2 gene non synonymous mutations were found. The L1 region showed various mutations which may be related to conformation changes of viral epitopes. Some transcription factor binding sites in the LCR region correlated to virulence were shown on GRE/1, TEF-1, YY14 and Oct-1. HPV16 European variant prone to single infection may harbor a major variation at L83V which significantly increases the risk for developing cervical carcinoma. HPV16 non-European variants prone to multiple infections may require many polymorphisms to enhance the risk of cervical cancer development.

복잡선천성 심장기형 완전교정수술후 시행한 복막투석의 임상적 고찰 (Peritoneal Dialysis after Correction of Complicated Congenital Heart Disease in Children)

  • 홍유선;박영환;조범구
    • Journal of Chest Surgery
    • /
    • 제29권8호
    • /
    • pp.844-849
    • /
    • 1996
  • 본 연세대학교 심장혈관센타에서는 1992년 I월부터 1993년 12월가지 체외순환을 시행하여 완전교정 을 시행한 복잡심장기형 환아 198명중 22예에서 복막투석을 시행하였다. 이들의 나이는 10일에서 6세 (평균 14.8$\pm$ 17.8개월)이었으며 복막투석의 적응증으로는 수분과부하상태가 10예, 혈장칼릅치가 5. Smmo111 이상인 경우가 3예, 그리고 충분한 양의 이뇨제를 투여함에도 소변양이 Imllkglhr 이하가 시간 이상 지속된 경우 9예에서 시행하였다. 체외순환이 90분 이상인 경우와 그 이하인 경우를 비교할 때 90분 이상 시행한 경우에 의미있게 많이 복막투석을 필요로 하였다(P<0.05). 1개월 미만 환아 13예중 5예(38%)에서 시행하였으나 그 이상의 나이와 비교할 때 의미있게 높지는 않았다(p : 0.08). 16예에서 신기능이 회복되었으나 4명은 호흡부전 또는 폐혈증으로 사망하였고 신기능이 회독되지 않 은 6예는 저심박출증이나 폐부종 등으로 모두 사망하였다. 아직도 사망률은 높으나 체 외순환 후 빈뇨, 수분과부하, 또는 고칼륨증이 있을 때에는 조기에 복막투석을 시행하는 것이 환자 치료에 도움이 되리라 사료된다.

  • PDF

초고주파 가열치료를 위한 MR 호환 동축 슬롯 안테나의 개발 (Development of MR Compatible Coaxial-slot Antenna for Microwave Hyperthermia)

  • 김태형;천송이;한용희;김동혁;문치웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.333-340
    • /
    • 2009
  • MR compatible coaxial-slot antenna for microwave hyperthermia was developed while its structure and size of each part were determined by computer simulation using finite element method(FEM). Its local heating performance was evaluated using tissue-mimic phantom and swine muscles. 2% agarose gel mixed with 6mM/$\ell$ $MnCl_2$ as a biological tissue-mimic phantom was heated by the proposed antenna driven by a 2.45GHz microwave generator. The temperature changes of the phantom were monitored using multi-channel digital thermometer at the distance of 0mm, 5mm, 10mm and 20mm from the tip center of the antenna. Also muscle tissue of swine was heated for 2 and 5minutes with 50W and 30W of microwave generator powers, respectively, to evaluate the local heating performance of the antenna. MRI compatibility was also verified by acquiring MR images and MR temperature map. MR signals were acquired from the agarose gel phantom using $T2^*$ GRE sequence with 1.5T clinical MRI scanner(Signa Echospeed, GE, Milwaukee, WI, U.S.A.) at Pusan Paik Hospital and were transferred to PC in order to reconstruct MR images and temperature map using proton resonance frequency(PRF) method and laboratory-developed phase unwrapping algorithm. Authors found that it has no severe distortion due to the antenna inserted into the phantom. Finally, we can conclude that the suggested coaxial-slot antenna has an excellent local heating performance for both of tissue-mimic phantom and swine muscle, and it is compatible to 1.5T MRI scanner.

Radiologic Determination of Corpus Callosum Injury in Patients with Mild Traumatic Brain Injury and Associated Clinical Characteristics

  • Kim, Dong Shin;Choi, Hyuk Jai;Yang, Jin Seo;Cho, Yong Jun;Kang, Suk Hyung
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권2호
    • /
    • pp.131-136
    • /
    • 2015
  • Objective : To investigate the incidence of corpus callosum injury (CCI) in patients with mild traumatic brain injury (TBI) using brain MRI. We also performed a review of the clinical characteristics associated with this injury. Methods : A total of 356 patients in the study were diagnosed with TBI, with 94 patients classified as having mild TBI. We included patients with mild TBI for further evaluation if they had normal findings via brain computed tomography (CT) scans and also underwent brain MRI in the acute phase following trauma. As assessed by brain MRI, CCI was defined as a high-signal lesion in T2 sagittal images and a corresponding low-signal lesion as determined by axial gradient echo (GRE) imaging. Based on these criteria, we divided patients into two groups for further analysis : Group I (TBI patients with CCI) and Group II (TBI patients without CCI). Results : A total of 56 patients were enrolled in this study (including 16 patients in Group I and 40 patients in Group II). Analysis of clinical symptoms revealed a significant difference in headache severity between groups. Over 50% of patients in Group I experienced prolonged neurological symptoms including dizziness and gait disturbance and were more common in Group I than Group II (dizziness : 37 and 12% in Groups I and II, respectively; gait disturbance : 12 and 0% in Groups I and II, respectively). Conclusion : The incidence of CCI in patients with mild TBI was approximately 29%. We suggest that brain MRI is a useful method to reveal the cause of persistent symptoms and predict clinical prognosis.

Histone deacetylase inhibition attenuates hepatic steatosis in rats with experimental Cushing's syndrome

  • Kim, Mina;Lee, Hae-Ahm;Cho, Hyun-Min;Kang, Seol-Hee;Lee, Eunjo;Kim, In Kyeom
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제22권1호
    • /
    • pp.23-33
    • /
    • 2018
  • Cushing's syndrome (CS) is a collection of symptoms caused by prolonged exposure to excess cortisol. Chronically elevated glucocorticoid (GC) levels contribute to hepatic steatosis. We hypothesized that histone deacetylase inhibitors (HDACi) could attenuate hepatic steatosis through glucocorticoid receptor (GR) acetylation in experimental CS. To induce CS, we administered adrenocorticotropic hormone (ACTH; 40 ng/kg/day) to Sprague-Dawley rats by subcutaneous infusion with osmotic mini-pumps. We administered the HDACi, sodium valproate (VPA; 0.71% w/v), in the drinking water. Treatment with the HDACi decreased steatosis and the expression of lipogenic genes in the livers of CS rats. The enrichment of GR at the promoters of the lipogenic genes, such as acetyl-CoA carboxylase (Acc), fatty acid synthase (Fasn), and sterol regulatory element binding protein 1c (Srebp1c), was markedly decreased by VPA. Pan-HDACi and an HDAC class I-specific inhibitor, but not an HDAC class II a-specific inhibitor, attenuated dexamethasone (DEX)-induced lipogenesis in HepG2 cells. The transcriptional activity of Fasn was decreased by pretreatment with VPA. In addition, pretreatment with VPA decreased DEX-induced binding of GR to the glucocorticoid response element (GRE). Treatment with VPA increased the acetylation of GR in ACTH-infused rats and DEX-induced HepG2 cells. Taken together, these results indicate that HDAC inhibition attenuates hepatic steatosis through GR acetylation in experimental CS.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

간 전이환자에서 최적의 펄스시퀀스에 따른 SPIO 특이성 조영제의 국소병변검출: Case review (Focal Lesion Detection of SPIO-specific agent Compared with Optimized Pulse Sequences in the Hepatic Metastases: Case Review)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.57-61
    • /
    • 2012
  • To compare the accuracy of breath-hold magnetic resonance imaging sequences to establish the most effective superparamagnetic iron oxide-enhanced sequence for detection of hepatic metastases. A total of 100 patients(50men and 50women, mean age: 60years) with liver disease(including malignant and benign liver lesions) were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) with 8Ch body coil. Pulse sequence for MR imaging decided to the FS-T2-FSE-RT(TR/TE/Thick./Freq./Phase=12857ms/100ms/7mm/512/384), MGRE(TR/TE/Thick./Freq./Phase=100ms/9.7ms/7mm/384/288), in-out of phase echo(TR/$TE_1$, $TE_2$/Thick./Freq./Phase=140ms/2.4, 5.8ms/7mm/352/300), Images obtained before the injection of SPIO. Six sequences were optimized for lesion detection: FS-T2-FSE-RT, multigradient recalled echo data image(MGRE), T2-weighted MGRE with an 9.7msec echo time. Images were reviewed independently by five blinded observers. The accuracy of each sequence was measured by using picture archiving communication system analysis. All results were correlated with findings at multidectator computed tomography examination. Differences between the mean results of the six observers were measured by using paired student t-test analysis. Postcontrast T2-weighted MGRE sequences were the most accurate and were significantly superior to postcontrast FS-T2-FSE-RT, T2-weighted MGRE, in-out of phase MR sequences(p < .05). For all lesions that were malignant or smaller than 1 cm, respectively, contrast to noise ratio of pre and postcontrast sequences were -1and -0.3 for T2-weighted FSE, 0.53 and 4.5 in-out of phase, 7, 7.08, 5.08, 3.32, 1.7, 1.16, 0.79, 0.68 for GRE with 2.9, 7.5, 12.1, 16.6, 21.2, 25.8, 30.4, 35.0 TE values. Breath-hold various TE precontrast sequences offer improvement in sensitivity compared with fixed multigradient recalled echo sequences alone.

  • PDF

미국교육에서 표준화시험의 역사적 전개와 시사점: 카네기재단의 역할 (A Historical Reappraisal on the Standardized Testing in the US Education Focusing on the Role of the Carnegie Foundation for the Advancement of Teaching)

  • 이윤미
    • 비교교육연구
    • /
    • 제28권4호
    • /
    • pp.51-82
    • /
    • 2018
  • 이 연구는 오늘날 학교교육에서 평가관을 지배하고 있는 표준화시험에 대해 미국의 사례를 중심으로 그 역사적 전개과정에 대해 고찰하고 시사점을 논한다. 특히 20세기 초 과학주의의 확산과 함께 표준화시험이 학교교육의 개선을 위해 적용되는 과정에서 카네기재단이 행한 매개적 역할에 주목하고 있다. 20세기 이래 표준화시험은 미국교육에서 중요한 지위를 지니고 있으며, 지식, 학력, 책무성을 강조하는 본질주의적 교육관을 대표하고 있어, 아동중심성, 경험, 민주주의 등을 강조하는 진보주의적 교육관과 대치되기도 한다. 표준화시험을 중심으로 한 미국교육의 전개과정에 대한 이해는 2000년대 이후 학력평가가 국제적으로 강화되고 있는 흐름에 대한 분석의 기초로서 중요하다.

Detection of Malignant Primary Hepatic Neoplasms with Gadobenate Dimeglumine (Gd-BOPTA) Enhanced T1-Weighted Hepatocyte Phase MR Imaging: Results of Off-site Blinded Review in a Phase-II Multicenter Trial

  • Constantino S. Pena;Sanjay Saini;Richard L. Baron;Bernd A. Hamm;Giovanni Morana;Roberto Caudana;Andrea Giovagnoni;Andrea Villa;Alessandro Carriero;Didier Mathieu;Michael W. Bourne;Miles A. Kirchin;Gianpaolo Pirovano;Alberto Spinazzi
    • Korean Journal of Radiology
    • /
    • 제2권4호
    • /
    • pp.210-215
    • /
    • 2001
  • Objective: To investigate the efficacy of gadobenate dimeglumine (GdBOPTA) enhanced MR imaging for the detection of liver lesions in patients with primary malignant hepatic neoplasms. Materials and Methods: Thirty-one patients with histologically proven primary malignancy of the liver were evaluated before and after administration of GdBOPTA at dose 0.05 or 0.10 mmol/kg. T1-weighted spin echo (T1W-SE) and gradient echo (T1W-GRE) images were evaluated for lesion number, location, size and confidence by three off-site independent reviewers and the findings were compared to reference standard imaging (intraoperative ultrasound, computed tomography during arterial portography or lipiodol computed tomography). Results were analyzed for significance using a two-sided McNemar's test. Results: More lesions were identified on Gd-BOPTA enhanced images than on unenhanced images and there was no significant difference in lesion detection between either concentration. The largest benefit was in detection of lesions under 1 cm in size (7 to 21, 9 to 15, 16 to 18 for reviewers A, B, C respectively). In 68% of the patients with more than one lesion, Gd-BOPTA increased the number of lesions detected. Conclusion: Liver MR imaging after Gd-BOPTA increases the detection of liver lesions in patients with primary malignant hepatic neoplasm.

  • PDF

슬관절 부위에서 자화전이 위상감도법에 의한 자화전이율 영상 평가 (Evaluation of Magnetization Transfer Ratio Imaging by Phase Sensitive Method in Knee Joint)

  • 윤문현;성미숙;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제19권4호
    • /
    • pp.269-275
    • /
    • 2008
  • 슬관절 퇴행성 질환을 진단하기 위하여 자기공명영상(magnetic resonance imaging: MRI)이 많이 사용되지만 간혹 슬관절 병후 및 예후를 잘못 진단하는 경우가 종종 발생한다. 본 연구에서는 슬관절 질환의 진단에 도움을 주기 위하여 자화전이(magnetization transfer: MT) 영상법을 소개하고자 한다. 슬관절 환자 7명으로부터 스핀 에코(SE) T2 강조 영상(3,400-3,500/90-100 ms)과 슬관절 환자 7명으로부터 FSE T2 강조 영상(4,500-5,000/100-108 ms)과 또한 슬관절 환자 3명으로부터 gradient echo (GRE) T2 강조 영상들(9/4.56 ms, 50 flip angle, NEX 1)을 획득하였다. 6명의 슬관절 환자에서 지방 억제가능 T2 강조 STIR 펄스시퀀스(TR/TE=2894-3215 ms/70 ms, NEX 3, ETL 9)를 사용하였다. 지방 포화도에 있어서 위상감도 방법은 Larmor frequency 차이에 따른 위상 차이를 이용하므로, 각각의 픽셀에 대한 자화전이율(magnetization transfer ratio: MTR)의 측정은 포화된 영상과 포화되지 않은 영상의 비율에 따라 산출하였다. 따라서 각 입력된 영상들은 동차원성을 가지고, 시각적으로 신호강도 정도가 회색의 명암도만으로 평가될 수 있기 때문에 생리학적, 정량적 진단을 위하여 3차원 등방성 체적영상과 자기공명 삼원색을 매핑하였고 정량적 특정은 자화전이율 지도로서 표현하였다. 자화전이율 영상은 병변 부위에서 높은 대조도를 나타내어 환자의 병태를 추적하는데 도움을 주었고 정량화하였다. 자화전이율 영상들과 기존의 MRI 사이에 명암도 차이는 회색상으로 표현되며, 자화전이율 영상화의 효과에 대해 프로파일 그래프는 자화전이 펄스로 인하여 신호강도에 있어서 정량적 측정값이 상대적으로 감소하였다. 슬관절의 정확한 병리상태를 진단하기 위해 프로파일 그래프의 측정값을 영상과 함께 표현하였다. 본 연구에서 수행한 예비적 데이터들을 통하여 슬관절의 자화전이율 영상들이 매우 임상학적으로 유용함을 확인하였다. 자화전이율 영상에 대한 물리적 변화를 관찰함으로써 자화전이율 영상에 대한 물리적, 기술적 기반에 대한 더 많은 통찰력을 제공할 수 있다. 무릎 질환 환자의 자화전이율 영상들을 이용하여 매우 높은 대조도를 확보할 수 있으므로 슬관절 질환의 정밀 진단에 매우 도움을 줄 수 있다.

  • PDF