• 제목/요약/키워드: GMB

검색결과 407건 처리시간 0.025초

수종의 의치상 레진과 레진치아의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength between Various Denture Bases Resin and Artificial Resin Teeth)

  • 이상욱;조인호;이준석
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.59-67
    • /
    • 2005
  • The bond strength of denture base resin and resin teeth, is an important factor in the long term prognosis of dentures. The purpose of this study is to find an appropriate combination of commercial denture base resin and artificial resin teeth according to shear bond strength. In this study, the shear bond strength of various denture base resins (Vertex $RS^{(R)}$(Dentimax Ziest, Holland), $PERform^{(R)}$(Hedent GmbH., Germany), SR $IVOCAP^{(R)}$(Ivoclar AG, Schaan, Liechtenstein)) and resin teeth (SR Orthosit PE(Ivoclar AG, Schaan, Liechtenstein), $Trubyte^{(R)}$ $Biotone^{(R)}$(Dentsply, U.S.A.)) was evaluated. 1. In comparison of denture resin, the shear bond strength increased in the order of $IVOCAP^{(R)}$, $PERform^{(R)}$, Vertex $RS^{(R)}$. 2. In resin teeth, $Trubyte^{(R)}$ $Biotone^{(R)}$ showed higher strength, but there was no statistical difference between the groups. 3. According to loading direction, the lingual showed higher strength, but there was no statistical difference. 4. When using SR Orthosit PE, SR $IVOCAP^{(R)}$ showed significantly higher shear bond strength(p<0.05). 5. Fracture tendancy showed more cohesive fractures(59) than adhesive failures(13). $IVOCAP^{(R)}$ showed the most superior results statistically. $Trubyte^{(R)}Biotone^{(R)}$ showed the highest shear bond strength. When using the SR Orthosit PE, it is thought that $IVOCAP^{(R)}$ would present the most superior results.

치과 임플란트 식립을 위한 치조골의 수직적 신장술 (VERTICAL DISTRACTION OF ALVEOLAR BONE FOR PLACEMENT OF DENTAL IMPLANT)

  • 오정환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.326-329
    • /
    • 2002
  • 저자들은 위축된 치조골과 외상 또는 종양으로 상실된 치조골의 재건을 위하여 수직적 치조골 신장술을 이용하여 104명의 환자에서 평균 10.2 mm의 치조골을 신장시킬 수 있었으며, 양호하게 재건된 치조골에 치과 임플란트를 식립함으로서 기능적, 심미적으로 좋은 결과를 얻을 수 있었다. 치조골 신장술은 기존의 치조골 수복술들을 대체할 수 있는 안전하고 효과적인 방법으로 생각된다.

백서 상부 소화기계의 발달 시기별 Telomerase 활성 및 PCNA(proliferating cell nuclear antigen)의 발현 변화 (THE CHANGES OF TELOMERASE ACTIVITY AND PROLIFERATING CELL NUCLEAR ANTIGEN(PCNA) EXPRESSION IN THE DEVELOPMENTAL STAGES OF RAT'S UPPER DIGESTIVE SYSTEM)

  • 성일용;김종렬
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제30권2호
    • /
    • pp.85-99
    • /
    • 2004
  • Purpose: This study observed the changes in the telomerase activity, it's developmental regulation, PCNA expression, and their correlation in rat's upper digestive organs during growth and aging. Materials and Methods: Upper digestive organs(buccal mucosa, gingiva, palate, submandibular and parotid glands, and tongue) were aseptically removed from Sprague-Dawley rats of fetal(gestational 20 days), growing(1, 2, 3, 5, and 7 weeks after birth) and adult(12 week old). Samples for telomerase activity were frozen on liquid nitrogen immediately after sacrifice, and stored until the use at $-75^{\circ}C$ in order to measure it. Telomerase activity was measured by a PCR-based telomeric repeat amplication protoco(TRAP) assay and quantitated with Photometric Telo TAGGG Telomerase PCR ELISA plus(Roche Diagnostics GmbH. Mannheim. Germany). PCNA expression were measured immunohistochemistry with anti PCNA Ab-1, Clone PC10(NeoMark. California. USA). Results: 1. Telomerase activities in buccal mucosa, palate and gingiva were the highest in fetus and decreased gradually or rapidly after birth and then diminished, but In salivary gland and tongue were the highest in fetus and also high at 1 week and then decreased rapidly. 2. PCNA expression in buccal mucosa, gingiva, Tongue and salivary gland was the highest in fetus and decreased gradually and then diminished. but only in palate decreased rapidly after birth and then diminished. Conclusion: The highest telomerase activity of embryonic stage decreased rapidly after birth in rat's upper digestive organs. There may be a developmental regulation of telomerase activity, but not a tissue-specific. This telomerase activity seems correlated closely with PCNA expression in rat's upper digestive system.

Dynamic Resource Reservation for Ultra-low Latency IoT Air-Interface Slice

  • Sun, Guolin;Wang, Guohui;Addo, Prince Clement;Liu, Guisong;Jiang, Wei
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권7호
    • /
    • pp.3309-3328
    • /
    • 2017
  • The application of Internet of Things (IoT) in the next generation cellular networks imposes a new characteristic on the data traffic, where a massive number of small packets need to be transmitted. In addition, some emerging IoT-based emergency services require a real-time data delivery within a few milliseconds, referring to as ultra-low latency transmission. However, current techniques cannot provide such a low latency in combination with a mice-flow traffic. In this paper, we propose a dynamic resource reservation schema based on an air-interface slicing scheme in the context of a massive number of sensors with emergency flows. The proposed schema can achieve an air-interface latency of a few milliseconds by means of allowing emergency flows to be transported through a dedicated radio connection with guaranteed network resources. In order to schedule the delay-sensitive flows immediately, dynamic resource updating, silence-probability based collision avoidance, and window-based re-transmission are introduced to combine with the frame-slotted Aloha protocol. To evaluate performance of the proposed schema, a probabilistic model is provided to derive the analytical results, which are compared with the numerical results from Monte-Carlo simulations.

Bond and fracture strength of metal-ceramic restorations formed by selective laser sintering

  • Bae, Eun-Jeong;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.266-271
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare the fracture strength of the metal and the bond strength in metal-ceramic restorations produced by selective laser sintering (SLS) and by conventional casting (CAST). MATERIALS AND METHODS. Non-precious alloy (StarLoy C, DeguDent, Hanau, Germany) was used in CAST group and metal powder (SP2, EOS GmbH, Munich, Germany) in SLS group. Metal specimens in the form of sheets ($25.0{\times}3.0{\times}0.5mm$) were produced in accordance with ISO 9693:1999 standards (n=30). To measure the bond strength, ceramic was fired on a metal specimen and then three-point bending test was performed. In addition, the metal fracture strength was measured by continuing the application of the load. The values were statistically analyzed by performing independent t-tests (${\alpha}=.05$). RESULTS. The mean bond strength of the SLS group (50.60 MPa) was higher than that of the CAST group (46.29 MPa), but there was no statistically significant difference. The metal fracture strength of the SLS group (1087.2 MPa) was lower than that of the CAST group (2399.1 MPa), and this difference was statistically significant. CONCLUSION. In conclusion the balling phenomenon and the gap formation of the SLS process may increase the metal-ceramic bond strength.

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

Color stability of provisional restorative materials with different fabrication methods

  • Song, So-Yeon;Shin, Yo-Han;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.259-264
    • /
    • 2020
  • PURPOSE. The aim of this study was to investigate and compare the color stability of provisional restorative materials fabricated by 3D printing, dental milling, and conventional materials. MATERIALS AND METHODS. For the experimental groups, two commercially available 3D-printing provisional resins (E-Dent 100; EnvisionTEC GmbH, Germany & VeroGlaze™; Stratasys®, USA), two dental milling blocks (PMMA Disk; Yamahachi Dental Co., Japan & Telio®CAD; Ivoclar Vivadent AG, Liechtenstein), and two conventional materials (Alike™; GC Co., Japan & Luxatemp automix plus; DMG, Germany) were used. The water sorption and solubility test were (n=10, respectively) carried out according to ISO4049:2000 (International Standards Organization, Geneva, Switzerland). For the color stability test (n=10), coffee and black tea were used as staining solutions, and the specimens were stored for 12 weeks. Data were analyzed by one-way ANOVA and Tukey's HSD using SPSS version 22.0 (SPSS Inc. Chicago, IL, USA) (P<.05). RESULTS. Alike and Veroglaze showed the highest values and Luxatemp showed the lowest water sorption. In the color stability test, the ΔE of conventional materials varied depending on the staining solution. PMMA milling blocks showed a relatively low ΔE up to 4 weeks, and then significantly increased after 8 weeks (P<.05). 3D-printed materials exhibited a high ΔE or a significant increase over time (P<.05). CONCLUSION. The degree of discoloration increased with time, and a visually perceptible color difference value (ΔE) was shown regardless of the materials and solutions. PMMA milled and 3D-printed materials showed more rapid change in discoloration after 8 weeks.

Comparing the accuracy of six intraoral scanners on prepared teeth and effect of scanning sequence

  • Diker, Burcu;Tak, Onjen
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.299-306
    • /
    • 2020
  • PURPOSE. The aim of this study was to evaluate the accuracy of six recently introduced intraoral scanners (IOSs) for single crown preparations isolated from the complete arch, and to determine the effect of scanning sequence on accuracy. MATERIALS AND METHODS. A complete arch with right and left canine preparations for single crowns was used as a study model. The reference dataset was obtained by scanning the complete arch using a highly accurate industrial scanner (ATOS Core 80, GOM GmbH). Six different IOSs (Trios, iTero, Planmeca Emerald, Cerec Omnicam, Primescan, and Virtuo Vivo) were used to scan the model ten times each. The scans performed with each IOS were divided into two groups, based on whether the scanning sequence started from the right or left quadrant (n=5). The accuracy of digital impression was evaluated using three-dimensional analyzing software (Geomagic Studio 12, 3D Systems). The Kruskal Wallis and Mann- Whitney U statistical tests for trueness analysis and the One-way ANOVA test for precision analysis were performed (α=.05). RESULTS. The trueness and precision values were the lowest with the Primescan (25 and 10 ㎛), followed by Trios (40.5 and 11 ㎛), Omnicam (41.5 ㎛ and 18 ㎛), Virtuo Vivo (52 and 37 ㎛), iTero (70 and 12 ㎛) and Emerald (73.5 and 60 ㎛). Regarding trueness, iTero showed more deviation when scanning started from the right (P=.009). CONCLUSION. The accuracy of digital impressions varied depending on the IOS and scanning sequence used. Primescan had the highest accuracy, while Emerald showed the most deviation in accuracy for single crown preparations.

Cognitive Behavioral Therapy in Breast Cancer Patients - a Feasibility Study of an 8 Week Intervention for Tumor Associated Fatigue Treatment

  • Eichler, Christian;Pia, Multhaupt;Sibylle, Multhaupt;Sauerwald, Axel;Friedrich, Wolff;Warm, Mathias
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권3호
    • /
    • pp.1063-1067
    • /
    • 2015
  • Background: Tumor associated fatigue (TAF) or cancer related fatigue (CRF) is not a new concept. Nonetheless, no real headway has been made in the quantitative analysis of its successful treatment via cognitive behavioral therapy. Since 20 to 30% of all breast cancer patients suffer from anxiety and/or depression within the first year of their diagnosis, this issue needs to be addressed and a standard treatment protocol has to be developed. This study focused on developing a simple, reproducible and short (8 weeks) protocol for the cognitive behavioral therapy support of tumor associated fatigue patients. Materials and Methods: Between the year 2011 and 2012, 23 breast cancer patients fulfilled the diagnosis TAF requirements and were introduced into this study. Our method focused on a psycho-oncological support group using a predetermined, highly structured and reproducible, cognitive behavioral therapy treatment manual. Eight weekly, 90 minute sessions were conducted and patients were evaluated before and after this eight session block. Tumor fatigue specific questionnaires such as the multidimensional fatigue inventory (MFI) as well as the hospital anxiety and depression scale (HADS) were used in order to quantitatively evaluate patient TAF. Results: Of the 23 patients enrolled in the study, only 7 patients fulfilled the TAF diagnostic criteria after the psycho-oncological group treatment. This represents a 70% reduction in diagnosable tumor associated fatigue. The HADS analysis showed a 33% reduction in patient anxiety as well as a 57% reduction in patient depression levels. The MFI scores showed a significant reduction in 4 of the 5 evaluate categories. With the exception of the "mental fatigue" MFI category all results were statistically significant. Conclusions: This study showed that a highly structured, cognitive behavioral therapy group intervention will produce significant improvements in breast cancer patient tumor associated fatigue levels after only 8 weeks.

영국.미국.일본선박보험약관의 비교연구 -오염손해, 보험사고 발생의 통지의무, 신구교환차익공제 및 중복보험에 관한 규정을 중심으로- (A Comparative Study on the Institute Time Clauses-Hulls 1995, American Institute Hulls Clauses 1977 and Japanese Hull Standard Clauses, 1990)

  • 홍성화;김기웅
    • 한국항해항만학회지
    • /
    • 제26권1호
    • /
    • pp.66-77
    • /
    • 2002
  • Generally hull insurance is undertaken by mean of a contract of hull insurance. A contract of hul1 insurance here is a contract whereby the insurer undertakes to indemnify the assured against the loss and damage to the vessel mused by maritime perils. A contract of hull insurance is consists of printed main insurance clauses and a clause includes many sub-clauses. Now the Institute Time Clauses-Hulls (hereunder refer to as "English hull insurance clauses"made by the Institute of London Underwriters is much used as the standard from or basic from by many countries ail over the world Now Korean insurance companies hue not made our their own hull insurance clauses, they have just adopted the made-out English hull insurance clauses and the english law and practice to solve the problem related to marine insurance. On the other hand, the United States of America and Japan have made out their own hull insurance clauses based on English hull insurance clauses and used the clauses for many years. Now American is using American Institute Hull Clauses(hereunder refer to as "American hul1 insurance clauses"as its own clauses which was made out by American Institute of Marine Underwriters in 1977 and Japan is also wing its own clauses named Japanese Hull Standard Clauses(hereunder refer to as "Japanese hull clauses") which was made out by japanese Hull Insurance Association in 1990. Therefore the purpose of this study is not only to make a comparative study on English hull insurance clauses 1995, American hull insurance clauses 1977 and Japanese hull clauses l990, but also to supply on some legal materials necessary for Korea to establish and perform our own hull insurance clauses.