• Title/Summary/Keyword: GI thickness

Search Result 521, Processing Time 0.023 seconds

Surface morphology of YBa$_{2}$Cu$_{3}$O$_{7}$ thin films prepared by the PLD method (PLD법으로 제작한 YBa$_{2}$Cu$_{3}$O$_{7}$ 반막의 표면상태 변화)

  • Han, Gi-Youl;Hwang, Tae-Jong;Yu, Seong-Cho;Lee, Kyu-Won;Ha, Dong-Han
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.66-69
    • /
    • 2000
  • We have observed the morphology of YBCO thin films grown on the SrTiO$_3$(100) substrates by the Pulsed Laser Deposition method. AFM and SEM images show that the YBCO grains grow spirally from their own seeds whereas outgrowths are considered to remain unchained as the film thickness increases. The images of various stages of film growth suggest that the outgrowths of 1000${\sim}$2000 ${AA}$ size are mainly formed at the very early stage of film growth. The results of XRD measurement clearly show that even a film of about 10 ${AA}$ thickness already forms orthorhombic YBCO structure although common superconducting resistivity behavior is known to be observed for the films with thickness above 100 ${AA}$.

  • PDF

Effects of Bedding Thickness of Sawdust on Environment of Cowshed Floor and Productivity of Hanwoo (깔짚 두께가 한우사 바닥환경과 생산성에 미치는 영향)

  • Kim, Seung-Gi;Park, Byung-Ki;An, Jun-Sang;Park, Myung-Ho;Ra, Chang-Six;Shin, Jong-Suh
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.65-72
    • /
    • 2012
  • This study was conducted to investigate the effects of bedding thickness of sawdust on feed intake, blood metabolites concentration and environmental condition of cowshed floor for Hanwoo. Feed intake was increased at thicker bedding groups (15 or 20cm), compared with thinner bedding group (10cm). The thicker bedding had a positive effect on concentration of serum total protein, high density lipoprotein (HDL)-cholesterol, low density lipoprotein (LDL)-cholesterol and ${\gamma}$-glutamyltransferase (GGT). Moisture content and the number of E. Coli in the bedding material were remarkably lower in 15 and 20 cm groups, compared with 10 cm group. Based on the data obtained in this study, approximately 20 cm bedding thickness or at least over 15 cm would be maintained to improve the health condition of Hanwoo and hence to enhance the productivity.

Development of Tilt angle measurement system of plastic thin-film using Position Sensitive Device (PSD를 이용한 플라스틱 박막 필름의 경사 각도 측정 시스템 개발)

  • Kim, Gi-Seung;Park, Yoon-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.134-138
    • /
    • 2021
  • Various types of precision plastic thin films are used widely in high-performance displays, such as smartphones. For plastic thin-films manufactured by the Roll-to-Roll process, the film thickness must be measured and managed while moving. In the Roll-to-Roll process, wrinkles are generated when tension is applied to the film, which causes an inclination on the optical axis of the thickness gauge, resulting in a loss of accuracy. Therefore, this study attempted to develop an optical interference tomography measurement system. In this study, the tilt angle of the film was measured to correct the measurement value error in the thickness gauge caused by the tilt of the film. The system was constructed so that the laser was irradiated on the tilted film, and the laser reflected from the film was formed on the PSD. The relationship between the tilt angle of the film and the output value of the PSD was obtained experimentally. Using this, a device to measure the tilt angle of the film was constructed, and angle measurements were taken at a speed of 250,000Hz.

Effects of Lumbar Stabilization Exercise using PNF Techniques on Thickness of Lumbar Deep Muscle and Functional Activity in Chronic Low Back Pain Patients (만성요통환자에서 PNF 기법을 이용한 요부안정화 운동이 요부 심부근 두께 및 기능적 활동에 미치는 효과)

  • Kim, Gi-Do;Lee, Yun-Jung;Choi, Wan-Suk;Lee, Dong-Woo;Jung, Dae-In;Kim, Kyung-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.233-243
    • /
    • 2012
  • The purpose of this study was to examine the effects of lumbar stabilization exercise using the PNF techniques on the lumbar deep muscles thickness and functional activity in chronic low back pain patient. Group I(n=10): general physical therapy group; Group II(n=10): general lumbar stabilization exercise group; Group III(n=10): lumbar stabilization exercise using PNF techniques(stabilizing reversal, rhythmic stabilization, combination of isotonic) group. Change of pain was measured with visual analog scale(VAS). To observe muscle thickness changes, we measured transverse abdominis(TrA), external oblique(EO), multifidus with real time ultrasound scanning. The functional activity were measured with Oswestry Disability Questionnaire(ODQ) and Roland & Morris Disability Questionnaire(RMDQ). In VAS test, group III had more significantly decreased than before exercise. In muscle thickness test, group III had more significantly increased than before exercise in right/left TrA, EO, multifidus. In ODQ & RMDQ test, group III had more significantly decreased than before exercise. This study show that the PNF techniques is effective in improving the lumbar stability and functional activity in chronic low back pain patients.

Algorithm for Primary Full-thickness Skin Grafting in Pediatric Hand Burns

  • Park, Yang Seo;Lee, Jong Wook;Huh, Gi Yeun;Koh, Jang Hyu;Seo, Dong Kook;Choi, Jai Koo;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.39 no.5
    • /
    • pp.483-488
    • /
    • 2012
  • Background Pediatric hand burns are a difficult problem because they lead to serious hand deformities with functional impairment due to rapid growth during childhood. Therefore, adequate management is required beginning in the acute stage. Our study aims to establish surgical guidelines for a primary full-thickness skin graft (FTSG) in pediatric hand burns, based on long-term observation periods and existing studies. Methods From January 2000 to May 2011, 210 patients underwent primary FTSG. We retrospectively studied the clinical course and treatment outcomes based on the patients' medical records. The patients' demographics, age, sex, injury site of the fingers, presence of web space involvement, the incidence of postoperative late deformities, and the duration of revision were critically analyzed. Results The mean age of the patients was 24.4 months (range, 8 to 94 months), consisting of 141 males and 69 females. The overall observation period was 6.9 years (range, 1 to 11 years) on average. At the time of the burn, 56 cases were to a single finger, 73 to two fingers, 45 to three fingers, and 22 to more than three. Among these cases, 70 were burns that included a web space (33.3%). During the observation, 25 cases underwent corrective operations with an average period of 40.6 months. Conclusions In the volar area, primary full-thickness skin grafting can be a good indication for an isolated injured finger, excluding the web spaces, and injuries of less than three fingers including the web spaces. Also, in the dorsal area, full-thickness skin grafting can be a good indication. However, if the donor site is insufficient and the wound is large, split-thickness skin grafting can be considered.

A STUDY OF PHYSICAL PROPERTIES OF COMPOSITE RESIN POLYMERIZATION WITH ARGON LASER (아르곤 레이저에 의한 복합레진의 중합시 물성 변화에 관한 연구)

  • Kim, Deok;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.1-19
    • /
    • 1998
  • After polymerizing composite resin with argon laser and visible light, four test, to be concretely, measurement of compressive strength using Instron testing machine, surface microhardness using Rockwell hardness tester, quantitative analysis of residual monomer using HPLC and analysis of degree of conversion using FTIR, were accomplished. Test groups were a sort of specimen with 3mm diameter, 4mm thickness for measuring compressive strength, two sort of specimen with 7mm diameter, 2mm and 3mm thickness for measuring surface microhardness, quantitative analysing of residual monomer after curing and measuring the degree of conversion, each were divided by six groups according to the condition of light exposure. In case of argon laser, in 1.0W and 0.5W output, the exposure time for specimen were 5 sec, 10 sec respectiyely. In case of visible light, the exposure time for specimen were 20 sec, 40 sec respectively. The test were accomplished and following results were obtained. 1. Compressive strength of composite resin was the highest in the group of 1 W output, exposing for 10 sec with argon laser, followed by the group of 0.5W, exposing for 10 sec with argon laser, the group of exposing for 40 sec with visible light. But there were statistically no significant difference between these three groups(p>0.05). 2. Surface microhardness of composite resin wasn't significantly affected by light curing conditions. 3. BIS-GMA within residual monomer was least detected in the group of exposing for 40 sec. TEGDMA was least detected in the group of 1 W output, exposing for 10 sec with argon laseboth 2mm and 3mm thickness specimen. 4. The degree of conversion of all groups in the 2mm thickness specimen were more than 50%, similar to each other but in the group of 1W, exposing 10 sec with argon laser the degree of conversion was highest in the 3mm thickness specimen. 5. Argon laser could make composite resin to has similar properties with 25% lesser exposure time than visible light.

  • PDF

Effect of Intense Regulated Pulse Light on Thickness of Tear Film Lipid Layer and Dry Eye Syndrome (조절펄스광선조사가 눈물막 지질층 두께 및 안구건조증에 미치는 효과)

  • Gil, Tae Young;Bae, Gi Hyun;Kwag, Joo Young;Hyun, Joo;Choi, Jin Seok;Pak, Kyu Hong;Chung, Sung Kun
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1103-1107
    • /
    • 2018
  • Purpose: To evaluate the clinical effect of intense regulated pulse light (IRPL) and changes in tear film thickness in dry eye patients. Methods: A retrospective study was conducted on 25 patients with Meibomian gland dysfunction who had subjective dry eye discomfort and whose tear film break-up time (TBUT) was < 10 seconds. All patients were treated with IRPL three times on days 1, 15, and 45. TBUT, Schirmer 1 test results, cornea staining score with fluorescein, ocular surface disease index (OSDI), and lipid layer thickness were measured and compared before and after the procedure. Results: TBUT was significantly increased from $3.7{\pm}1.2s$ to $4.4{\pm}2.1s$ after IRPL (p = 0.03). Schirmer 1 test and cornea staining scores changed significantly (p < 0.01 and p = 0.01, respectively). OSDI also showed a statistically significant improvement from $39.5{\pm}17.5points$ to $30.4{\pm}18.7points$ (p = 0.01). However, no significant difference in lipid layer thickness was observed (p = 0.49). Conclusions: IRPL is an effective treatment modality to improve TBUT, Schirmer 1 test scores, cornea staining scores, and subjective dry eye symptoms.

The Visualization of Temperature Field for Nanoporous Thin Film using Laser-Induced Fluorescence. (형광 나노포러스 박막의 온도장 가시화)

  • Oh, Young-Su;Baek, In-Gi;Jeon, Pil-Soo;Kim, Hyun-Jung;Yoo, Jai-Suk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2459-2464
    • /
    • 2007
  • In present study, a temperature field of specimens which was coated with fluorescence dye such as Rhodamine-B(Rh-B) has been measured, based on the fluorescence intensity. Silica(SiO2) nano porous structure with 1um thickness was constructed on a cover glass, and fluorescence dye was digested into these porous thin films. To optimize manufacturing coating process, various solvents, Rh-B concentration, and other chemical materials were applied to fabricate the specimen and all specimens were measured on the various temperature conditions. For the measurement, a 14 bit cooled CCD camera with 1600 by 1200 spatial resolution is equipped with epifluorescence microscope to obtain only fluorescence intensity from 1.2 mm by 0.9 mm field of view of the illuminated coated specimen.

  • PDF

The Relationship Between Local and Overall Buckling of Rectangular Tubes (II) (사각튜브의 국부좌굴과 전체좌굴에 관한 연구 (2))

  • Han, Byeong-Gi;Park, Bog-Hyeon;An, Dae-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.895-904
    • /
    • 1998
  • This paper presents the results of experimental investigation of the buckling behavior of thin-walled box-section column. The experiments for finding the buckling stress and bifurcation slenderness ratio are performed by the method from AISC. The sets of boundary conditions are both end simply supported, one end simply supported and the other end clamped, and both ends clamped. The types of specimens are clssified by thickness to width ratio. The experiments for the thin-walled rectangular tubes are closely concurrent with the theoretical values of overall buckling load and bifurcation slenderness ratio that are suggested by the part (I) of this paper.